Specification update
Enterprise Platforms and Services MarketingEnterprise Platforms and Services Division
Monthly Specification Upd
8
2. The RAID controller information may be intermingled with the platform
information displayed by BIOS.
Implication There is no functional impact associated with this erratum.
Status This issue was fixed in BIOS R0038.
Workaround None.
10.
The PXE boot option is missing in BIOS Setup
Problem If a user disables the primary (onboard) video in BIOS Setup and enable
console redirection, the PXE boot option will disapear from the BIOS Boot
Manager.
Implication Users that desire to utilize the PXE boot option must leave the primary
(onboard) video enabled.
Status This issue may be fixed in a future BIOS revision.
Workaround None.
11.
Fans may boost temporarily when BMC is under load
Problem The system fans may boost when the BMC is operating under a heavy load.
This can include large sequential BMC tasks such as viewing the system event
log, configuring the BMC or resetting the system. The fans return to normal
automatically after the BMC operations complete
Implication The systems fans will run at a higher state temporarily, increasing acoustics.
Status This issue was fixed with BMC 00.36.
Workaround None.
12.
Extra events may be seen in the SEL during system reset
Problem The BMC may log periodic, spurious SEL events during a system reset. These
events may appear as fan errors or double appearances of normal events. The
spurious fan readings will only happen during reset and are not an indication of