Specification update
Monthly Specification UpdateEnterprise Platforms and Services Marketing
Enterprise Platforms and Services Divis
9
an actual fan failure. Fan failure events that occur during a reboot should be
ignored.
To identify when a reboot happened, locate the following events, which are
normally logged after system rest or AC power cycle:
System Event/BIOS Evt Sensor (# 0x83) Timestamp Clock Sync. 1
st
of pair. Asserted Event.
System Event/BIOS Evt Sensor (# 0x83) Timestamp Clock Sync. 2
nd
of pair. Asserted Event.
Implication The SEL log may indicate fan errors or double instances of normal events
intermittently.
Status This issue was fixed with BMC 00.36.
Workaround None
13.
BIOS setup may report incorrect firmware versions
Problem The BIOS setup screens to display the versions of SDR and ME firmware
version may report an incorrect version. The version displayed may be of the
previously installed versions.
Implication After firmware update, the BIOS screens may not show the correct version until
the system is AC cycled.
Status This issue may be fixed in a future BMC release.
Workaround None.
14.
Onboard SATA controller SW RAID mode is not available when Intel® SAS
Entry RAID Module AXX4SASMOD is set to Intel
®
ESRTII mode
Problem The SW RAID mode for BIOS setup option: Configure SATA Mode is not
avaialbe, when the Intel
®
SAS Entry RAID Module AXX4SASMOD is installed
and set to Intel
®
ESRTII mode.
Implication Users that desire to use both onboard SATA controller and Intel
®
SAS Entry
RAID Module AXX4SASMOD module in Intel
®
ESRTII mode simultaneously
will not be able to do so.