Specification update

Enterprise Platforms and Services MarketingEnterprise Platforms and Services Division
Monthly Specification Upd
Status This issue was resolved with BIOS R0037.
Workaround None.
15.
When battery is missing, firmware will think it is there
Problem If the server board battery is missing, firmware will think it is there and good.
Implication There is no function impact associated with this erratum. Firmware will however
monitor the battery health if it is present
Status No Fix.
Workaround None.
16.
SES connection is not enabled in Intel® SAS Entry RAID Module
AXX4SASMOD firmware v2009.03.24
Problem The SES connector is available on the Intel
®
SAS Entry RAID Module
AXX4SASMOD, but the SES connection is not enabled in Intel
®
SAS Entry
RAID Module AXX4SASMOD firmware v2000.03.24.
Implication Users that desire to use SES connection on AXX4SASMOD for Intel
®
non-
expander backplanes AXX4DRV3GR and AXX6DRV3GR fault LED control will
not be able to do it.
Status This issue was fixed with Intel
®
SAS Entry RAID Module AXX4SASMOD
firmware package v2009.08.06_ph16p3.
Workaround None.
17.
Closed Loop Thermal Throttling (CLTT) is not automatically detected and
set when using unbuffered memory (UDIMM)
Problem When using UDIMMs, CLTT will not be automatically selected if using the
“Auto” feature on the System Accoustics and Performance page of BIOS setup.