Technical Product Specification

Appendix C: BMC Sensor Tables Intel® Server Boards S5520HC, S5500HCV, and S5520HCT TPS
Revision 1.9
Intel order number E39529-013
156
Full Sensor Name
(Sensor name in SDR)
Sensor #
Platform
Applicability
Sensor Type
Event/Reading
Type
Event Offset
Triggers
Contrib. To
System Status
Assert/De
-assert
Readable
Value/Offs
ets
Event
Data
Rearm
Stand-
by
Fan Present Sensors
(Fan x Present)
40h45h
Chassis-
specific
Fan
04h
Generic
08h
01 - Device
inserted
OK
As and
De
-
Triggered
Offset
Auto
Fan Redundancy
1
(Fan Redundancy)
46h
Chassis-
specific
Fan
04h
Generic
0Bh
00 - Fully
redundant
OK
As and
De
Trig Offset
A
01
Redundancy lost
Degraded
02 - Redundancy
degraded
Degraded
03 - Non-
redundant:
Sufficient
resources.
Transition from
redundant
Degraded
04 - Non-
redundant:
Sufficient
resources.
Transition from
insufficient.
Degraded
05 - Non-
redundant:
insufficient
resources.
Non-fatal
06 Non-
Redundant:
degraded from
fully redundant.
Degraded