Technical Product Specification

Intel® Server Boards S5520HC, S5500HCV, and S5520HCT TPS Appendix C: BMC Sensor Tables
Revision 1.9
Intel order number E39529-013
157
Full Sensor Name
(Sensor name in SDR)
Sensor #
Platform
Applicability
Sensor Type
Event/Reading
Type
Event Offset
Triggers
Contrib. To
System Status
Assert/De
-assert
Readable
Value/Offs
ets
Event
Data
Rearm
Stand-
by
07 - Redundant
degraded from
non-redundant
Degraded
Power Supply 1 Status
(PS1 Status)
50h
Chassis-
specific
Power
Supply
08h
Sensor
Specific
6Fh
00 - Presence
OK
As and
De
Trig Offset
A
X
01 - Failure
Degraded
02 Predictive
Failure
Degraded
03 - A/C lost
Degraded
06
Configuration
error
OK
Power Supply 2 Status
(PS2 Status)
51h
Chassis-
specific
Power
Supply
08h
Sensor
Specific
6Fh
00 - Presence
OK
As and
De
Trig Offset
A
X
01 - Failure
Degraded
02 Predictive
Failure
Degraded
03 - A/C lost
Degraded
06
Configuration
error
OK
Power Supply 1
AC Power Input
(PS1 Power In)
52h
Chassis-
specific
Other Units
0Bh
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-fatal
As and
De
Analog
R, T
A
X
Power Supply 2
AC Power Input
(PS2 Power In)
53h
Chassis-
specific
Other Units
0Bh
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-fatal
As and
De
Analog
R, T
A
X
Power Supply 1 +12V % of
Maximum Current Output
(PS1 Curr Out %)
54h
Chassis-
specific
Current
03h
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-fatal
As and
De
Analog
R, T
A
X
Power Supply 2 +12V % of
Maximum Current Output
(PS2 Curr Out %)
55h
Chassis-
specific
Current
03h
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-fatal
As and
De
Analog
R, T
A
X