Technical Product Specification
Appendix C: BMC Sensor Tables Intel® Server Boards S5520HC, S5500HCV, and S5520HCT TPS
Revision 1.9
Intel order number E39529-013
158
Full Sensor Name
(Sensor name in SDR)
Sensor #
Platform
Applicability
Sensor Type
Event/Reading
Type
Event Offset
Triggers
Contrib. To
System Status
Assert/De
-assert
Readable
Value/Offs
ets
Event
Data
Rearm
Stand-
by
Power Supply 1
Temperature
(PS1 Temperature)
56h
Chassis-
specific
Temperature
01h
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-fatal
As and
De
Analog
R, T
A
X
Power Supply 2
Temperature
(PS2 Temperature)
57h
Chassis-
specific
Temperature
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-fatal
As and
De
Analog
R, T
A
X
Processor 1 Status
(P1 Status)
60h
All
Processor
07h
Sensor
Specific
6Fh
01 - Thermal trip
Fatal
As and
De
–
Trig Offset
M
X
07 - Presence
OK
Processor 2 Status
(P2 Status)
61h
Dual
processor
only
Processor
07h
Sensor
Specific
6Fh
01- Thermal trip
Fatal
As and
De
–
Trig Offset
M
X
07 - Presence
OK
Processor 1 Thermal
Margin
(P1 Therm Margin)
62h
All
Temperature
01h
Threshold
01h
–
–
–
Analog
–
–
–
Processor 2 Thermal
Margin
(P2 Therm Margin)
63h
Dual
processor
only
Temperature
01h
Threshold
01h
–
–
–
Analog
–
–
–
Processor 1 Thermal
Control %
(P1 Therm Ctrl %)
64h
All
Temperature
01h
Threshold
01h
[u] [c,nc]
Non-fatal
As and
De
Analog
Trig Offset
A
–
Processor 2 Thermal
Control %
(P2 Therm Ctrl %)
65h
Dual
processor
only
Temperature
01h
Threshold
01h
[u] [c,nc]
Non-fatal
As and
De
Analog
Trig Offset
A
–
Processor 1 VRD Temp
(P1 VRD Hot)
66h
All
Temperature
01h
Digital
Discrete
05h
01 - Limit
exceeded
Fatal
As and
De
–
Trig Offset
M
–
Processor 2 VRD Temp
(P2 VRD Hot)
67h
Dual
processor
only
Temperature
01h
Digital
Discrete
05h
01 - Limit
exceeded
Fatal
As and
De
–
Trig Offset