207 Intel® RAID Software User Guide
Figure 132. Battery Backup Unit Information
The BBU properties include the following:
The number of times the BBU has been recharged (Cycle Count)
The full capacity of the BBU, plus the percentage of its current state of charge, and
the estimated time until it will be depleted
The current BBU temperature, voltage, current, and remaining capacity
If the battery is charging, the estimated time until it is fully charged
9.21.7 Battery Learn Cycle
Learn Cycle is a battery calibration operation performed by the controller periodically to
determine the condition of the battery. You can start battery learn cycles manually or
automatically. To choose automatic battery learn cycles, enable automatic learn cycles. To
choose manual battery learn cycles, disable automatic learn cycles.
If you enable automatic learn cyles, you can delay the start of the learn cycles for up to
168 hours (7 days). If you disable automatic learn cycles, you can start the learn cycles
manually, and you can choose to receive a reminder to start a manual learn cycle.