Users guide
Intel® RAID Software User Guide 258
copyback on|off
type =
smart
ssd|smarthdd|all
smartssd:
Copy back enabled
for SSD drives.
smarthdd:
Copy back enabled
for HDD drives.
all:
Copy back enabled for both
ssd drives and HDD drives.
Example:
storcli /cx set
copyb
ack=on type=all
Enables/disables copy back for
drive typ
es.
directpdmapping on|off Enables/disables direct physical
drive mapp
ing. When enclosures
are used, this feature is disabled;
otherwise it should be enabled.
eccbucketleakrate 0 to 65535 Sets leak rate of the single-bit
bucket in minutes (one
entry
removed per leak-rate).
eccbucketsize 0 to 255 Sets size of ECC single-bit-error
bucket (l
ogs event when full).
enableeghsp on|off Enables/disables the
commissioning of otherwise
incompatible global hot spare
drives as Emergency Hot Spare
(EHSP) drives.
enableesmarter on|off Enables/disables the
commi
ssioning of Emergency Hot
Spare (EHSP) drives for
Predictive Failure (PFA) events.
enableeug on|off Enables/disables the
commi
ssioning of Unconfigured
Good drives as Emergency Hot
Spare (EHSP) drives.
exposeencldevice on|off Enables/disables device drivers
to
expose enclosure devices; for
example, expanders, SEPs.
dimmerswitch|ds See “Dimmer Switch
Commands” on page29
3.
See “Dimmer Switch Commands”
on page293.
foreignautoimport on|off Imports foreign configuration
automatical
ly, at boot.
jbod on|off Enables/disables JBOD mode; by
default, drives becom
e system
drives. Not supported by all
controllers.
Property Name Set Command Range Description