Users guide

293 IntelĀ® RAID Software User Guide
Input example:
storcli /c0/dx show
storcli /cx/dx show all
This command shows the physical drive and the virtual drive information for the drive
group.
Input example:
storcli /c0/dx show all
storcli /cx/dx set security=on
This command enables security on the specified drive group.
Input example:
storcli /c0/dx set security=on all
10.5.8 Dimmer Switch Commands
10.5.8.1 Change Virtual Drive Power Settings Commands
The Storage Command Line Tool supports the following command to change the Dimmer
Switch* setting. The Dimmer Switch is the power-saving policy for the virtual drive.
storcli /cx/vx set ds=<default | auto | none | max | maxnocache>
This command changes the power-saving properties on a virtual drive. See
dimmerswitch in the following table for values.
Input example:
storcli /cx/vx set ds=default
Note: Only the ds3 dimmer switch option cannot be selected in the Storage Command Line Tool.
You can use the following combinations for the dimmer sw
itch commands:
storcli /cx set ds=off type=1|2|3|4
storcli /cx se
t ds=on type=1|2 [properties]
storcli /cx se
t ds=on type=3|4 defaultldtype=<value> [properties]
storcli /cx se
t ds=on [properties]
The following table describes the power-saving options.
Table 34. Dimmer Switch Input Options
Option Value Range Description
dimmerswitch or
ds
on|off Turns the dimmer switch option
on.