Users guide
295 Intel® RAID Software User Guide
storcli /cx/bbu set writeaceess=sealed
storcli /cx/bb
u show modes
storcli /cx/bb
u show properties
storcli /cx/bb
u show status
storcli /cx/bb
u start learn
The detailed description for each command follows.
storcli /cx/bbu show
This command shows the summary information for the BBU of a controller.
Input example:
storcli /c0/bbu show
storcli /cx/bb
u show all
This command shows all the information of the BBU.
Input example:
storcli /c0/bbu show all
storcli /cx/bb
u set autolearnmode=<value>
This command starts the automatic learn cycle on the battery. The possible values are 0 -
Enabled,
1- Disabled, and 2 - WarnViaEvent.
Input example:
storcli /c0/bbu set autolearnmode=0
storcli /cx/bb
u set bbuMode=<value>
This command sets the BBU mode for the BBU. The following table shows the various
BBU modes.
Table 35. BBU Mode
Mode Description
0 48 hours of retention
A
at 60 °C, 1-year Service Life.
1 12 hours of retention at 45 °C, 5-year Service Life, tran
sparent learn
B
.
2 12 hours of retention at 55 °C, 3-year Service Life, tran
sparent learn.
3 24 hours of retention at 45 °C, 3-year Service Life, tran
sparent learn.
4 48 hours of retention at 45 °C, 3-year Service Life.
5 48 hours of retention at 55 °C, 1-year Service Life.
6 The same as the description for BBU mode 5. The BBU mode 6 enables
you to re
ceive events when the battery capacity reaches suboptimal and
critical thresholds.