Quick Start Guide Page 2

A complete list of accessories and spares can be found at:
http://www.intel.com/p/en_US/support/highlights/server/s5520ur
Front Panel Controls and Indicators
Intel® Local Control Panel Standard Control Panel
O M L K J HIN G
C
D
E
F
BA
J IL K
BA F G HEDC
A NIC2 Activity LED
B. NIC1 Activity LED
C. Power/Sleep Button
D. Power/Sleep LED
E. Hard Drive
Activity LED
F. Status LED
G. System ID LED
H. System ID
Button
I. Reset
Button
J. USB 1.1
Port
K. NMI
(recessed)
Button
L. Video (hot-
swap drive
system only)
A USB 1.1 Port
B. LCD Display
C. Menu Control Button - Up
D. Menu Control Button - Down
E. Menu Control Button - Left
F. Menu Control Button - Enter
G. ID LED
H. Power/Sleep LED
I. Power/Sleep Button
J. System Status
LED
K. NIC 2 Activity
LED
L. NIC 1 Activity LED
M. HDD Activity LED
N. Reset Button
O. USB 1.1 Port
19
Install Top Cover
Note:
Security screw
re-installation is optional.
A
Place cover as shown, slide forward
to engage recessed edge at
front of cover. Make sure
latch is locked.
A
Recessed
Edge
18
Install Rack
Handles
Note: Rack handles are required to
install the bezel. For instructions,
see the Service Guide.
A
17
Install Intel® Local Control Panel (optional)
Press the blue locking lever at the
back of the control panel and push
it forward to release it
from the chassis.
B
Disconnect the front panel and USB
cables from the backplane as shown.
A
Slide the control
panel and cables
out of the chassis.
C
Slide control panel fully into chassis until
the locking lever engages.
F
Feed local control panel cables into chassis opening.
E
Connect the USB and data cables to the local control panel as
shown.
D
Connect the two cables to the USB
and front panel connectors on the
backplane as shown.
G
Remove Standard Control Panel Install Local Control Panel
C
A
D
D
F
B
Locking
Lever
Server
Board
Local
Control Panel
E
Backplane
G
A
Note: The Intel
®
Local Control Panel option is only supported in hot-swap drive systems.
16
Install PCI Add-in Card
Riser Assembly
PCI Riser
Socket
Chassis
Slots (2)
Hooks (2)
Riser Card
Edge Connector
Processor
Air Duct
Air Duct
Slot
Position riser card edge connector over
the server board riser socket and align
the two hooks in the riser with the slots
at the back of the chassis.
A
Press down uniformly until the
two hooks on the rear of the
PCI riser assembly
engage the chassis
back panel slots.
The riser card will seat
into the matching riser
socket on the server
board.
B
Note that the riser assembly card edge installs in
the slot in the processor air duct.
15
Install Add-in Card
(optional)
A
Remove filler panel from the add-in card slot.
B
Insert add-in card until it seats in riser connector.
C
Secure the add-in card with screw as shown.
CAUTION:
Observe normal
ESD precautions
when installing
the add-in card.
Riser Connector
REMOVE Filler Panel
A
C
Remove the screw as shown.
D
D
B
14
Install Processor
Air Duct
Use care to avoid
pinching system
cables.
Processor
Air Duct
Install processor
air duct as shown
making sure the front
edge of the duct aligns
correctly with the notches
on the fan module.
11
Install Hot-swap Drive System Components ...
for a Fixed Drive System, go to Step 12
Position backplane over
six chassis standoffs.
A
Engage standoffs
and slide the
backplane in the
direction shown
to lock into place.
B
Tighten blue
thumbscrew.
C
Install the Backplane
Note: Both the active and passive backplanes install the same.
Open the backplane bridge board connector
retention
clip.
A
Install the Bridge Board
Route the five fan
module cables over
the fan guard and
connect to the
corresponding
connectors on the
backplane.
A
Connect the USB and
data cables from the
control panel to the
USB and front panel
connectors on the
backplane.
B
Make Cable Connections
Connect the power
supply cable to the
power connector
located on the
backplane.
C
Passive Backplane Only: Connect the
hard drive SATA cables from the server
board to the corresponding SATA
connectors on the backplane.
D
A
C
Active Backplane
B
B
Server
Board
A
B
Bridge Board
Install bridge board making
sure the connector edges on
both sides align correctly
with the slots, and by
pressing down on both
sides simultaneously.
Close the retention clips.
B
A
Install Hot-swap Hard Drives
Drive 0 Primary
Hard Drive Numbering Diagram
1
2
0
Repeat these steps for each
installed hard drive.
Remove hot-swap drive
carrier(s) by pushing
green latch towards the lever,
opening the lever all the way,
and then pulling the drive
carrier out of the system.
A
Remove the plastic air
baffle and save for
future use.
B
Install the hard disk
drive and attach
with four
screws.
C
With the carrier lever in the
OPEN position, slide drive
assembly into chassis
until it stops, then
close the lever until
it snaps shut.
D
CAUTION: If you install less than three drives or devices, empty drive bays must be
occupied by carriers with baffles to maintain proper system cooling. To avoid possible
damage to your chassis, use only carriers that came with your server system.
Install Air Baffle
Cabling Legend:
Main Power Cable
CPU Power Cable
Power Signal Cable
Optical Drive Data Cable
SATA 0-2 HDD Data Cables
(passive backplane only)
Route all applicable
cables (see the ‘Cabling Legend’
below) through the baffle
notches and snap air
baffle into place.
The baffle is held in place by two
snap-standoffs on the chassis floor.
A
Note: Front tab
of air baffle must fit
under the drive bay
cover prior to lowering
into chassis standoffs
to ensure a proper fit.
Make sure that all the
cables are seated over
the backplane.
SATA 0
SATA 1
SATA 2
Passive
Backplane
Fan Connectors
B
C
Fan Module
A
SATA 0
SATA 1
SATA 2
SATA
Connector
Detail
D
D
SATA Conn.
Details
D
Server Board
Snap
Stand-offs
Power Signal
Main Power
CPU Power
SATA Connector
SATA Connectors
Power
Supply
SATA 0 HDD
SATA 1 HDD
Optical Drive
Front
Tab
SATA 2 HDD
A
Standoff Detail
Air Baffle
USB
Cable
Data
Cable
12
Install Fixed Drive System Components...for a Hot-swap Drive System, go to Step 11
SATA 0
SATA 1
SATA 2
Backplane
Fixed
Drive 1
Power
Supply
Cable
Connector
Install Hard Drive Cables
Connect SATA data cable(s) to server board as shown.
A
Connect opposite end of SATA data cable(s) to
hard drive(s) as shown ... see detail below.
B
Connect the SATA fixed drive power
connectors to each hard drive
as shown ... see detail.
C
BLUE indicates Data Cable
RED indicates Power Cable
Cable
Legend
Data
Power
Back View of
SATA Drive
B
C
A
Server
Board
Install Air Baffle
Standoff Detail
Front
Tab
Main Power
CPU Power
Power Signal
SATA Connector
Cabling Legend:
Main Power Cable
CPU Power Cable
Power Signal Cable
Optical Drive
Data Cable
SATA 0-2 HDD
Data Cables
SATA 0-2 HDD
Power Cables
Route all applicable
cables (see below)
through the baffle
notches and snap air
baffle into place.
The baffle is held in place by two
standoffs on the chassis floor.
A
Note: Front tab
of air baffle must fit
under the drive bay
cover prior to lowering
into chassis standoffs
to ensure a proper fit.
Drive Bay Cover
Power
Supply
SATA Connectors
Power
Supply
SATA 0 HDD
SATA 1 HDD
SATA 2 HDD
Fixed
SATA
Drive 0
Fixed
SATA
Drive 1
Optical Drive
Air Baffle
A
Install Fixed Hard Drives/Carriers
Slide each carrier
into a drive opening
until the blue carrier
latch clicks into place.
Repeat these steps for
each installed hard drive
CAUTIONS: If you install less than three drives,
empty drive bays must be occupied by carriers
with baffles to maintain proper system cooling.
To avoid possible damage to your chassis, use
only carriers that came with your server system.
Remove the Plastic Air Baffle
B
D
Install the hard
disk drive
and attach
with four
screws.
C
Install 1st drive
here.
Install 2nd
drive here.
Hard Drive Numbering Diagram
1
2
0
Carrier
Latch
Remove fixed drive carrier(s)
by pressing blue carrier latch
from inside the chassis, pushing
the drive carrier forward, and
sliding it out of the system.
A
Install 3rd
drive here.
Fixed
Drive 2
Optical
Device
Fixed
Drive 0
Fixed
SATA
Drive 2
Backplane
13a
Install SATA Optical Device (optional)
1. Remove the
Empty Tray
2. Install Device into the Tray
Align the two
holes on the
left edge of
the optical
device with
the two
metal tabs
in the tray.
A
3. Install Optical Device Tray
Assembly into the Chassis
Pull the power and
data cables through
the front of the
chassis opening.
A
A
Remove the empty
tray from the
accessory kit box.
Empty
Optical
Device Tray
B
Metal Tab
A
CAUTION:
To maintain
proper system cooling, a
filler blank must be
installed if you do not
install a device at this
location.
Optical
Device Tray
Assembly
Blue Release
Lever
C
D
Optical
Device Tray
Assembly
Optical
Drive
B
Data
Power
Connect the cables
as shown.
B
A
Lower opposite side of optical
device into the tray until it
clicks into place.
B
From the back side of the device
bay, pull the cables back into
the chassis opening as
you insert the device.
C
Verify that the blue
release lever on the
tray locks into place.
D
Note: The power end of the SATA optical device cable comes
attached to the midplane board power cable.
13b
A
Connect the SATA end of the cable to one of the server board
SATA connectors.
Server Board
SATA
Connectors
SATA Conn.
Detail
Power
Supply
A
SATA Cable
from Optical Device
4. Install Optical Device Data Cable
AXXHERAIL2
Cable Management Arm
Tool-less Rail Kit
ADWBEZBLACKBezel for Standard Control Panel
Optional Accessories and Order Codes
AXXRACKARM2
AXXBASRAIL13
Fixed Bracket Kit
Basic Slide Rail Kit
AXXBRACKETS
ADWLCDBEZEL
Bezel for Intel
®
Local Control Panel
Infiniband* I/O Expansion Module
AXXSATADVDROM
Slimline DVD-ROM/CD-ROM Drive
AXXLCPRACK2
Intel
®
Local Control Panel
AXXGBIOMOD
Dual Gigabit I/O Expansion Module
AXXSASIOMOD
SAS I/O Expansion Module
10 Gigabit I/O Expansion Module
AXXRMM3
AXXIBIOMOD
Intel
®
Remote Management Module 3
AXX10GBIOMOD
Quad-Port Gigabit I/O Expansion
Module
AXX4GBIOMOD2
20
Finishing Up
Before installing your operating system, you must finish
your system installation, make I/O connections, and plug in
AC power.
AC Power
CAUTION: This unit must
be operated with the TOP
COVER installed to ensure
proper cooling.
Video
1. Replace the system cover.
I/O Exp. Module
USB 0-3
Intel
®
RMM3 Module
Serial
Port A
Network
NIC1-2
2. Install the server into the rack using the instructions provided
with the rack mounting kit.
3.
Connect your USB keyboard/mouse, video and other I/O
cables/devices as shown. Then connect the AC power cord.
21
Software
BIOS, Drivers, and Operating System
Installation
C. Install your Operating System:
Use the instructions provided with the RAID
controller and with the operating system.
D. Install Operating System Drivers:
With the operating system running, insert the
Intel
®
Server Deployment Toolkit CD. If using a Microsoft Windows* operating
system, the Express Installer will autorun and allow you to select the appropriate drivers
to install. On other operating systems, browse the CD folders to locate and install the
driver files.
A. Update the System Software:
1. Boot from the Intel
®
Server Deployment Toolkit CD.
2. Use the Wizard to access the latest versions on the Internet and update the BIOS,
firmware, FRUSDRs, and Intel
®
RMM3.
Note: You can also use downloaded files on a USB key.
B. Configure your RAID Controller:
If using a RAID card, use the instructions
provided with the RAID controller. If using on-board RAID, you must activate RAID in
the BIOS setup. See the Intel
®
Server Board S5520UR Technical Product
Specification for more information.
E. Install Intel
®
System Management Software (optional):
Download the latest version of the Intel
®
System Management Software from
http://www.intel.com/go/servermanagement and use the instructions provided at that
link to install the software.
Intel® Server Board S5520UR
Component Layout
See your Intel
®
Server System SR1600UR Service Guide for expanded component
and connection information.
Diag.
LEDs
USB
8, 9
USB
2, 5
Video
ID LED
Serial A
CPU 1
I/O Exp.
Module Conn. 1
I/O Exp.
Module Conn. 2
SGPIO
SATA Key
LCP/AUX IPMB
BMC Force
Update
Front USB
SSD
USB
Power
Supply
Signal
Conn.
Serial B
SATA 5
SATA 0
SATA 1
SATA 2
SATA 3
SATA 4
DIMM
Status
LEDs
CPU 2
Fan
Mem 2
Fan
CPU
Power
Front
Panel
CPU 2
Bridge Board Conn.
Sys 1
Fan
Sys 2
Fan
NIC1
NIC2
DIMM A2
DIMM C1
DIMM A1
DIMM B2
DIMM B1
DIMM C2
Main Power
Fan Board
DIMM Status LEDs
Battery
DIMM F1
DIMM D2
DIMM F2
DIMM E1
DIMM E2
DIMM D1
PCIe* Riser
RMM3 Conn.
CPU 1 Fan
Mem 1 Fan
Status
LED
BIOS
Recover
Password
Clear
BIOS
Default
Serial Port
Config.
Document/Tool
Available Documents
Technical Product Specification
Spares, Parts List, and Configuration Guide
Server Configurator Tool
Software and Drivers
Content
In-depth technical information
Supported accessories and spares list
Tested peripherals and operating systems list
Tested memory list
Supported processors list
Up-to-date firmware, driver, and utility information
A link to the above documents, Server Configurator Tool, and the Software and Drivers web page
can be found at: http://www.intel.com/p/en_US/support/highlights/server/s5520ur.