Intel® Server System SR1600UR Technical Product Specification Intel order number E45725-010 Revision 1.
Revision History Intel® Server System SR1600UR TPS Revision History Date Revision Number Modifications March 2009 1.0 Initial release. October 2009 1.1 Updated section 7.3 - Control Panel Connectors. January 2010 1.2 Update section 2.5 - NIC Connectors. April 2010 1.3 Updated section 2.5 - System Board Overview. Removed CCC Certification. July 2010 1.4 Updated section 2 - Product Overview, Added section 2.1.1 - Processor Support. October 2010 1.5 Updated section 2.1.
Intel® Server System SR1600UR TPS Table of Contents Table of Contents 1. Introduction ........................................................................................................................1 1.1 Chapter Outline ......................................................................................................1 1.2 Server Board Use Disclaimer .................................................................................2 2. Product Overview .......................................
Table of Contents Intel® Server System SR1600UR TPS 4.2 Power Supply Fans ..............................................................................................26 4.3 CPU Air Duct and Air Baffle .................................................................................26 4.4 Drive Bay Population ............................................................................................27 5. Peripheral Support ...........................................................................
Intel® Server System SR1600UR TPS 11.1 Table of Contents Product Regulatory Compliance ...........................................................................58 11.1.1 Product Safety Compliance ..................................................................................58 11.1.2 Product EMC Compliance – Class A Compliance ................................................ 59 11.1.3 Product Ecology Compliance ...............................................................................
List of Figures Intel® Server System SR1600UR TPS List of Figures Figure 1. Top Down View – Hot-Swap Drive SKU Shown ...........................................................7 Figure 2. Major Chassis Components .........................................................................................8 Figure 3. Drive Bay Overview......................................................................................................9 Figure 4. Intel® Server Board S5520UR ....................................
Intel® Server System SR1600UR TPS Table of Contents Figure 32. Diagnostic LED Placement Diagram ........................................................................69 Revision 1.
List of Tables Intel® Server System SR1600UR TPS List of Tables Table 1. System Feature Set ......................................................................................................3 Table 2. Mixed Processor Configurations....................................................................................6 Table 3. Processor Support Matrix ..............................................................................................7 Table 4. Drive Overview ...................................
Intel® Server System SR1600UR TPS List of Tables Table 32. System Fan Connector Pin-outs................................................................................44 Table 33. IPMB Connector Pin-out (J1C1) ................................................................................44 Table 34. Add-in Card Connector Pin-out (J4B3 – Passive Only) ............................................. 45 Table 35. Control Button and Intrusion Switch Functions .................................................
List of Tables Intel® Server System SR1600UR TPS < This page is intentionally left blank. > x Intel order number E45725-010 Revision 1.
Intel® Server System SR1600UR TPS 1. 0BIntroduction Introduction This Technical Product Specification (TPS) provides system-specific information detailing the features, functionality, and high-level architecture of the Intel® Server System SR1600UR. The Intel® Server Board S5520UR Technical Product Specification should also be referenced to obtain greater detail of functionality and architecture specific to the integrated server board, but which are also supported on this server system.
0BIntroduction 1.2 Intel® Server System SR1600UR TPS Server Board Use Disclaimer Intel Corporation server boards support add-in peripherals and contain a number of highdensity VLSI and power delivery components that need adequate airflow to cool. Intel® ensures through its own chassis development and testing that when Intel® server building blocks are used together, the fully integrated system will meet the intended thermal requirements of these components.
Intel® Server System SR1600UR TPS 2. 1BProduct Overview Product Overview The Intel® Server System SR1600UR is a rack mount 1U server system with features that are designed to support the high-density high-performance computing server market.
1BProduct Overview Intel® Server System SR1600UR TPS Feature Expansion Capabilities Hard Drive Options Description One x16 PCI Express* Gen 2 PCI riser slot capable of supporting a full-length fullheight PCI Express* add-in card. Fixed mount hard drive system: Three SATA drives Hot-swap hard drive system: Three 3.
Intel® Server System SR1600UR TPS 2.1.1 1BProduct Overview Processor Support ® The Intel Server Boards S5520UR supports the following processors: One or two Intel® Xeon® Processor 5500 Series with a 4.8 GT/s, 5.86 GT/s, or 6.4 GT/s Intel® QPI link interface and Thermal Design Power (TDP) up to 95 W. One or two Intel® Xeon® Processor 5600 Series with a 6.4 GT/s Intel® QPI link interface and Thermal Design Power (TDP) up to 130 W.
1BProduct Overview Intel® Server System SR1600UR TPS Table 2. Mixed Processor Configurations Error Processor family not identical Severity Fatal System Action The BIOS detects the error condition and responds as follows: Logs the error into the system event log (SEL). Alerts the Integrated BMC of the configuration error with an IPMI command. Does not disable the processor. Displays “0194: Processor family mismatch detected” message in the error manager. Halts the system.
Intel® Server System SR1600UR TPS 2.2 1BProduct Overview System Overview Figure 1. Top Down View – Hot-Swap Drive SKU Shown 2.3 System Dimensions Table 3. Processor Support Matrix Revision 1.8 Height 43.3 mm 1.70 in Width without rails 430 mm 16.9 in Width with rails 451.6 mm 17.78 in Depth without CMA 690.6 mm 27.19 in Depth with CMA 844.5 mm 33.25 in Maximum Weight 15.
1BProduct Overview 2.
Intel® Server System SR1600UR TPS 2.5 1BProduct Overview Hard Drive and Peripheral Bays Table 4.
1BProduct Overview 2.6 Intel® Server System SR1600UR TPS System Board Overview ® Figure 4. Intel Server Board S5520UR The following figure shows the board layout of the server board. Each connector and major component is identified by a number or letter, and a description is provided below the figure. 10 Intel order number E45725-010 Revision 1.
Intel® Server System SR1600UR TPS 1BProduct Overview ® Figure 5. Intel Server Board S5520UR Components Revision 1.
1BProduct Overview Intel® Server System SR1600UR TPS Table 5.
Intel® Server System SR1600UR TPS 1BProduct Overview A POST Code Diagnostic LEDs F CPU 1 DIMM Fault LEDs B System Identification LED G CPU 2 Fan Fault LED C Status LED H Memory 2 Fan Fault LED D Memory 1 Fan Fault LED I CPU 2 DIMM Fault LEDs E CPU 1 Fan Fault LED J 5V Standby LED ® Figure 7. Intel Light-Guided Diagnostic LEDs - Server Board Revision 1.
1BProduct Overview 2.7 Intel® Server System SR1600UR TPS Front Bezel Support The optional front bezel is made of molded plastic and uses a snap-on design. When installed, its design allows for maximum airflow to maintain system cooling requirements. Separate front bezels are available to support systems that use either a standard control panel (Product Order Code – ADWBEZBLACK) or an Intel® Local Control Panel (Product Order Code – ADWLCDBEZEL). Figure 8.
Intel® Server System SR1600UR TPS 1BProduct Overview Light pipes in the front bezel support the standard control panel and allow the system status LEDs to be monitored when the bezel is installed. When the local control panel is used, the control panel module can be adjusted to extend further out from the chassis face to allow the LCD panel to protrude from the front bezel.
Power Subsystem 3. Intel® Server System SR1600UR TPS Power Subsystem The power subsystem consists of a single non-redundant 600-W power supply with eight outputs: 3.3 V, 5 V, 12 V1, 12 V2, 12 V3, 12 V4, -12 V, and 5 VSB. The input is auto-ranging and power factor corrected. The form factor is SSI EPS1U compliant with a 300-mm depth and wire harness output. The power supply provides two non-redundant 40-mm fans for self cooling. These power supply fans also provide additional airflow for the system.
Intel® Server System SR1600UR TPS 3.2 Power Subsystem Output Connectors The power supply has a cable harness with four power connectors that are used to power various platform subsystems. The following table defines each power connector. Table 6.
Power Subsystem 3.2.2 Intel® Server System SR1600UR TPS P2 – Processor Power Connector Connector housing: 8-pin Molex* 39-01-2085 or equivalent Contact: Molex 45750-0112 (12A) or equivalent Table 8. P2 – Processor Power Connector Pin-out Pin Signal 18 AWG Color Pin Signal 18 AWG Color 1 COM Black 5 +12 V1 2 COM Black 6 +12 V1 Yellow 3 COM Black 7 12 V4 Blue/White Stripe 4 COM Black 8 12 V4 Blue/White Stripe 3.2.
Intel® Server System SR1600UR TPS 3.2.5 Power Subsystem P5 – Slimline SATA Optical Disk Drive (SSATA ODD) Power Connector Connector housing: 6-pin Slimline SATA Power Contact: 15u” plating minimum Table 11. P5 – Slimline SATA Optical Disk Drive Power Connector Pin 3.2.6 Signal 22 AWG Color 1 Reserved N.C. 2 +5 VDC Red 3 +5 VDC Red 4 Reserved N.C.
Power Subsystem 3.3 Intel® Server System SR1600UR TPS Efficiency The following table provides the required minimum efficiency level at various loading conditions. These are provided at three different load levels: 100%, 50% and 20%. Efficiency is tested over an AC input voltage range of 115 VAC to 220 VAC. Table 13. Efficiency Loading 100% of maximum 50% of maximum 20% of maximum Minimum Efficiency >80% >80% >80% 3.
Intel® Server System SR1600UR TPS 3.5.1 Power Subsystem Over-current Protection (OCP) The power supply has current limits to prevent the +3.3 V, +5 V, and +12 V outputs from exceeding the values shown in the following table. If the current limits are exceeded, the power supply shuts down and latches off. The latch is cleared by toggling the PSON# signal or by an AC power interruption. The power supply is not damaged from repeated power cycling in this condition.
Power Subsystem 3.5.3 Intel® Server System SR1600UR TPS Over-temperature Protection (OTP) The power supply is protected against over-temperature conditions caused by loss of fan cooling or excessive ambient temperature. In an OTP condition, the PSU shuts down. When the power supply temperature drops to within specified limits, the power supply restores power automatically, while the 5 VSB remains constantly on.
Intel® Server System SR1600UR TPS Power Subsystem Figure 11. AC Power Cord Revision 1.
Cooling Subsystem 4. Intel® Server System SR1600UR TPS Cooling Subsystem The cooling subsystem is composed of five 40x40x56-mm dual-rotor fans, two 40x40x28-mm power supply fans, a CPU air duct, and a power supply/electronics bay isolation air baffle. These components are used to provide the necessary cooling and airflow to the system. A fan on the processor heatsink is not necessary in this chassis.
Intel® Server System SR1600UR TPS Cooling Subsystem Table 19.
Cooling Subsystem Intel® Server System SR1600UR TPS Note: There is no fan redundancy. Should a fan fail, the system should be powered down as soon as possible to have the fan replaced. The system fans are not hot-swappable. 4.2 Power Supply Fans The power supply supports two non-redundant 40-mm fans. They are responsible for the cooling of the power supply, first hard drive bay, and slimline drive bay. 4.
Intel® Server System SR1600UR TPS 4.4 Cooling Subsystem Drive Bay Population The hard drive bays must be populated in order to maintain system thermal requirements. Hard drive trays used for both hot-swap drives and cabled drives must either have a hard drive or drive blank installed in them. Inserting a drive tray into the system with no hard drive or drive blank installed may prevent the system from meeting its thermal requirements. AF002196 Figure 14.
Peripheral Support 5. Intel® Server System SR1600UR TPS Peripheral Support The system provides a slimline drive bay that can be populated with a SATA optical drive (CDROM, DVD, DVD/CDR) or a USB floppy drive. Drives are mounted on a tool-less tray which allows for easy installation and removal from the system. The slimline devices are not hot-swappable. AF002198 Figure 15. View of Slimline Drive Bay 5.
Intel® Server System SR1600UR TPS 5.2 Peripheral Support Optical Drive Support The system has support for a slimline SATA optical drive. The drive is mounted onto a tool-less drive tray. The drive assembly is then inserted into the slimline drive bay. A 7-pin SATA cable is used to connect the drive assembly to a matching SATA connector on the server board. Table 22.
Hard Disk Drive Support 6. Intel® Server System SR1600UR TPS Hard Disk Drive Support The Intel® Server System SR1600UR is available in two hard drive configurations: fixed drive SATA and hot-swap SATA/SAS. The hard drive bays are designed to support tray mounted 3.5 inch x 1 inch hard drives. Depending on the configuration, the system can either support up to three fixed mount SATA drives, or up to three hot-swap SATA or SAS drives.
Intel® Server System SR1600UR TPS Hard Disk Drive Support Hot-swap drive trays make insertion and extraction of the drive from the system very simple. Each drive tray has its own dual purpose latching mechanism, which is used to insert and extract drives from the chassis and lock the tray in place. Each drive tray supports a light pipe to direct light from the drive status LED, located on the backplane, to the tray’s face plate. This makes it visible from the front of the system.
Hard Disk Drive Support 6.3.1 32 Intel® Server System SR1600UR TPS Backplane Feature Set Vitesse VSC410 enclosure management controller o Integrated v3000 32 bit RISC microprocessor core o External non-volatile Flash ROM 2 o Four I C interfaces o 44 GPIO pins Three drive control connectors supporting either SATA ports from the server board or SAS/SATA ports from an add-in card (passive backplane only) LSISAS1064E SAS/SATA controller (active backplane only) o Four-port, 3.
Intel® Server System SR1600UR TPS Hard Disk Drive Support The following figures show the layout of major components and connectors for each backplane. A B C D E F G H Backplane Power USB Floppy Connector SATA 0 SATA 1 Fan 5 Power Bridge Board Connector Fan 4 Power Fan 3 Power I J K L M N O Fan 2 Power Front Panel Connector Fan 1 Power Screw Front Panel USB SATA 2 Hot-swap SAS/SATA Connectors Figure 19. Hot-swap Passive SAS/SATA Backplane Layout Revision 1.
Hard Disk Drive Support A B C D E F G Intel® Server System SR1600UR TPS Backplane Power USB Floppy Connector SW RAID Activation Key Fan 5 Power Bridge Board Connector Fan 4 Power Fan 3 Power H I J K L M Fan 2 Power Front Panel Connector Fan 1 Power Screw Front Panel USB Hot-swap SAS/SATA Connectors Figure 20. Active SAS Backplane Layout 34 Intel order number E45725-010 Revision 1.
Intel® Server System SR1600UR TPS Hard Disk Drive Support The following figures show the functional blocks for each backplane.
Hard Disk Drive Support 6.3.1.1 Intel® Server System SR1600UR TPS Vitesse VSC410 Enclosure Management Controller Both the active and passive backplanes support enclosure management using a Vitesse VSC410 management controller. The VSC410 drives the hard drive activity/fault LED, hard drive present signal, and controls hard drive power-up during system power-on.
Intel® Server System SR1600UR TPS Hard Disk Drive Support Each of the four SAS PHYs on the LSISAS1064E is capable of SAS/SATA link rates of 3.0 Gb/s and 1.5 Gb/s. The user can configure ports as wide or narrow. Narrow ports have one PHY per port. Wide ports have two, three, or four PHYs per port. Each port supports the SSP, SMP, STP, and SATA protocols.
Hard Disk Drive Support 6.3.2 Intel® Server System SR1600UR TPS LED Support The backplanes support an activity/fault LED for each of the hard drive connectors. The LED illuminates green for activity or amber for a drive fault. The green activity LED is driven by the SAS/SATA hard disk drive directly. The amber fault LED is driven by the VSC410 management controller whenever a fault condition is detected.
Intel® Server System SR1600UR TPS Hard Disk Drive Support Table 25. Backplane Power Connector Pin-out (J1B1) 6.3.3.2 Pin Name Pin Name 1 Ground 5 +12 V 2 Ground 6 +12 V 3 +5 V 7 5 VSB 4 +5 V 8 +3.3 V Bridge Board Interface (Backplane to Server Board) The backplanes provide a pathway for the control panel, PCI Express*, USB, and other miscellaneous signals from the server board to connector interfaces on the backplane.
Hard Disk Drive Support Intel® Server System SR1600UR TPS The following table provides the pin-out for the 120-pin connector: Table 26.
Intel® Server System SR1600UR TPS Pin Hard Disk Drive Support Signal Name Pin Signal Name 41 SMB_PBI_5VSB_DAT 101 SMB_IPMB_5VSB_DAT 42 SMB_PBI_5VSB_CLK 102 SMB_IPMB_5VSB_CLK 43 GND 103 GND 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 V_IO_HSYNC2_BUF_FP V_IO_VSYNC2_BUF_FP GND V_IO_BLUE_CONN_FP V_IO_GREEN_CONN_FP V_IO_RED_CONN_FP GND LED_FAN6_FAULT LED_FAN5_FAULT LED_FAN4_FAULT FAN_PWM3 GND PCI_FAN_TACH10 FAN_TACH8 FAN_TACH6 FAN_TACH4_H7 FAN_TACH2_H7 104 105 106 107 108 109 110 111 1
Hard Disk Drive Support Pin # 37 39 41 43 45 47 49 6.3.3.
Intel® Server System SR1600UR TPS Hard Disk Drive Support Pin# Signal Description P4 P5 P6 P7 P8 P9 P10 P11 P12 P13 P14 P15 PTH0 PTY1 6.3.3.6 Ground Ground P3V3 P5V P5V P5V Ground LED_SAS#_ACT_L (# = 0…2) Ground P12V P12V P12V Ground Ground SATA/SAS Drive Control Connectors (Passive Backplane Only) The passive backplane includes three drive control connectors.
Hard Disk Drive Support 6.3.3.8 Intel® Server System SR1600UR TPS System Fan Connectors The backplanes provides a pathway for signals from the server board to monitor and control five system fans. A 1x10 mini connector is provided for each of the fans. The following table provides the pin-out for each connector. Table 32.
Intel® Server System SR1600UR TPS Hard Disk Drive Support Table 34. Add-in Card Connector Pin-out (J4B3 – Passive Only) Pin # 1 2 3 6.4 Description SMB_3V3_SAS_SDA GND SMB_3V3_SAS_SCL Enclosure Management Cabling for Passive Backplane When using a rack-optimized system with a passive backplane and an add-in RAID card, you must install an additional 3-pin cable between the RAID card and the backplane to enable fault LED control. The cable is included with your integrated system or the backplane kit.
Standard Control Panel 7. Intel® Server System SR1600UR TPS Standard Control Panel The standard control panel supports several push buttons and status LEDs, along with USB and video ports to centralize system control, monitoring, and accessibility within a common compact design. The control panel assembly comes pre-assembled and is modular in design. The control panel assembly module slides into a predefined slot on the front of the chassis.
Intel® Server System SR1600UR TPS Standard Control Panel Table 35. Control Button and Intrusion Switch Functions Reference A B C Function Power/Sleep Button ID Button Toggles the system power on/off. This button also functions as a Sleep button if enabled by an ACPI-compliant operating system. Toggles the front panel ID LED and the server board ID LED on/off.
Standard Control Panel Intel® Server System SR1600UR TPS LED Color On Amber Disk Activity System Identification State Description Critical or non-recoverable condition. Blink 1,2 Off Off Green Random blink Non-critical condition. POST/system stop. 3 Provides an indicator for disk activity. Off Off Blue On No hard disk activity Identify active via command or button. Off Off No Identification. Notes: 1. Blink rate is ~1 Hz at 50% duty cycle. 2.
Intel® Server System SR1600UR TPS Color State Standard Control Panel Criticality Description up. In a mirrored configuration, when memory mirroring takes place and system loses memory redundancy. This is not covered by the second bullet above. Redundancy loss such as power supply or fan. This does not apply to non-redundant subsystems. PCI Express* link errors. CPU failure/disabled – if there are two processors and one of them fails. Fan alarm – Fan failure.
Standard Control Panel 7.3 Intel® Server System SR1600UR TPS By issuing the appropriate hex IPMI “Chassis Identify” value, the ID LED either blinks blue for 15 seconds and turns off or blinks indefinitely until the appropriate hex IPMI chassis identify value is issued to turn it off. Control Panel Connectors The control panel has two external I/O connectors: One USB port One VGA video port The following tables provide the pin-outs for each connector. Table 39.
Intel® Server System SR1600UR TPS 8. Intel® Local Control Panel Intel® Local Control Panel The Intel® Local Control Panel (Product Order Code – ADWLCDBEZEL) utilizes a combination of control buttons, LEDs, and LCD display to provide system accessibility, monitoring, and control functions. The control panel assembly is pre-assembled and is modular in design. The module slides into a slot on the front of the chassis and is designed so that it can be adjusted for use with or without an outer front bezel.
Intel® Local Control Panel 8.1 Intel® Server System SR1600UR TPS LED Functionality The following table identifies each LED and describes its functionality. Table 41. Control Panel LED Functions LED NIC1/NIC2 Activity Color On NIC Link Green Blink NIC Activity Green On Legacy power-on/ACPI S0 state Blink Off Off Green On System Identification Sleep/ACPI S1 state Running/normal operation Blink Amber 1,4 Power-off/ACPI S4 or S5 state 1,2 On Degraded Critical or non-recoverable condition.
Intel® Server System SR1600UR TPS 8.1.2 Intel® Local Control Panel System Status LED Table 43. Control Panel LED Operation Color State Criticality Description Off N/A Not ready AC power off Green Solid on Ok System booted and ready Green Blink Degraded System degraded Unable to use all of the installed memory (more than one DIMM installed). Correctable errors over a threshold of ten and migrating to a spare DIMM (memory sparing).
Intel® Local Control Panel 8.1.4 Intel® Server System SR1600UR TPS System Identification LED The blue system identification LED is used to help identify a system for servicing. This is especially useful when the system is installed in a high-density rack or cabinet that is populated with several similar systems. The blue “System ID” LED can be illuminated using one of the following mechanisms.
Intel® Server System SR1600UR TPS 9. PCI Riser Cards and Assembly PCI Riser Cards and Assembly The Intel® Server System SR1600UR provides one x16 PCI Express* Gen 2 PCI riser slot capable of supporting one full-length full-height PCI Express* add-in card. When re-inserting the riser assembly into the chassis, tabs on the back of the assembly should be aligned with slots on the back edge of the chassis. The tabs fit into the slots securing the riser assembly to the chassis when the top cover is in place.
Environmental Specifications Intel® Server System SR1600UR TPS 10. Environmental Specifications 10.1 System Level Environmental Limits The following table defines the system level operating and non-operating environmental limits. Table 44.
Intel® Server System SR1600UR TPS Environmental Specifications 10.3 Replacing the Backup Battery The lithium battery on the server board powers the real time clock (RTC) for up to 10 years in the absence of power. When the battery starts to weaken, it loses voltage, and the server settings stored in CMOS RAM in the RTC (e.g., the date and time) may be wrong. Contact your customer service representative or dealer for a list of approved devices.
3BRegulatory and Certification Information Intel® Server System SR1600UR TPS 11. Regulatory and Certification Information WARNING To ensure regulatory compliance, you must adhere to the assembly instructions in this document to ensure and maintain compliance with existing product certifications and approvals. Use only the described, regulated components specified in this document.
Intel® Server System SR1600UR TPS 11.1.
Regulatory and Certification Information Intel® Server System SR1600UR TPS MED Declaration of Conformity (New Zealand) BSMI Certification (Taiwan) GOST R Certification/Certification (Russia) Belarus Certification/Certification (Belarus) KCC Certification (Korea) IRAM Certification (Argentina) Ecology Declaration (International) China RoHS Environmental Friendly Use Period Packaging & Product Recycling Marks 11.
Intel® Server System SR1600UR TPS Regulatory Compliance Regulatory and Certification Information Country GOST R Marking Russia KCC Mark (Korean Communications Comission) Korea Belarus Safety Compliance Mark Belarus Waste of Electronic and Electrical Equipment Recycling Mark Europe China Restriction of Hazardous Substance Environmental Friendly Use Period Mark China China Recycling Mark China Recycling Marks International Battery Perchlorate Warning Information California Safety Multiple
Regulatory and Certification Information Regulatory Compliance Intel® Server System SR1600UR TPS Country Marking 本设备包括多条电源系统电缆。为避免遭受电击,在进行维 修之前应断开两(2)条电源系统电缆。 Traditional Chinese: 注意: 本設備包括多條電源系統電纜。為避免遭受電擊,在進行維 修之前應斷開兩( 2) 條電源系統電纜。 German: Dieses Geräte hat mehr als ein Stromkabel. Um eine Gefahr des elektrischen Schlages zu verringern trennen sie beide (2) Stromkabeln bevor Instandhaltung.
Intel® Server System SR1600UR TPS Regulatory and Certification Information Over-current protection: The server is designed for an AC line voltage source with up to 20 amperes of over-current protection per cord feed. If the power system for the equipment rack is installed on a branch circuit with more than 20 amperes of protection, you must provide supplemental protection for the server.
Regulatory and Certification Information Intel® Server System SR1600UR TPS 11.4 Power Cord Usage Guidelines WARNING Do not attempt to modify or use an AC power cord set that is not the exact type required. You must use a power cord set that meets the following criteria: Rating: In the U.S. and Canada, cords must be UL (Underwriters Laboratories, Inc.) Listed/CSA (Canadian Standards Organization) Certified type SJT, 18-3 AWG (American Wire Gauge). Outside of the U.S.
Intel® Server System SR1600UR TPS Regulatory and Certification Information Any changes or modifications not expressly approved by the grantee of this device could void the user’s authority to operate the equipment. The customer is responsible for ensuring compliance of the modified product. Only peripherals (computer input/output devices, terminals, printers, etc.) that comply with FCC Class A or B limits may be attached to this computer product.
Regulatory and Certification Information 11.5.5 Intel® Server System SR1600UR TPS BSMI (Taiwan) The BSMI Certification Marking and EMC warning is located on the outside rear area of the product. 11.5.6 KCC (Korea) Following is the KCC certification information for Korea. English translation of the notice above: 1. 2. 3. 4. 5. Type of Equipment (Model Name): On Certification and Product ® Certification No.: On KCC certificate.
Intel® Server System SR1600UR TPS Regulatory and Certification Information appropriate telecommunications, safety, and EMC approvals for the region in which it is sold. Peripheral Storage Devices — must be UL recognized or UL listed accessory and TUV or VDE licensed. Maximum power rating of any one device or combination of devices cannot exceed manufacturer’s specifications. Total server configuration is not to exceed the maximum loading conditions of the power supply. Revision 1.
Appendix A: Integration and Usage Tips Intel® Server System SR1600UR TPS Appendix A: Integration and Usage Tips This section provides a list of useful information that is unique to the Intel® Server System SR1600UR and should be kept in mind while integrating and configuring your Intel® Server Board S5520UR. 68 Only low-profile (1.2 in or 30.48 mm) DIMMs can be used in the server chassis. Processor fans are not supported and are not needed in the server chassis.
Intel® Server System SR1600UR TPS Appendix B: POST Code Diagnostic LED Decoder Appendix B: POST Code Diagnostic LED Decoder During the system boot process, the BIOS executes a number of platform configuration processes, each of which is assigned a specific hex POST code number. As each configuration routine is started, the BIOS displays the POST code to the POST Code Diagnostic LEDs on the back edge of the server board.
Appendix B: POST Code Diagnostic LED Decoder Intel® Server System SR1600UR TPS Table 47.
Intel® Server System SR1600UR TPS Diagnostic LED Decoder O = On, X=Off Upper Nibble Lower Nibble Checkpoint MSB 8h #7 X X X 4h LED #6 0x55h O 0x56h O 0x57h O USB 0x58h X O 0x59h X O ATA/ATAPI/SATA 0x5Ah X O 0x5Bh X O SMBUS 0x5Ch X O 0x5Dh X O Local Console 0x70h X O 0x71h X O 0x72h X O Remote Console 0x78h X O 0x79h X O 0x7Ah X O Keyboard (only USB) 0x90h O X 0x91h O X 0x92h O X 0x93h O X 0x94h O X 0x95h O X Mouse (only USB) 0x98h O X 0x99h O X 0x9Ah O X 0x9Bh O X Fixed Media 0xB0h O X 0xB1h O X 0xB2h A
Appendix B: POST Code Diagnostic LED Decoder Diagnostic LED Decoder O = On, X=Off Upper Nibble Lower Nibble Checkpoint MSB 8h #7 4h #6 2h #5 1h #4 O O X O 0xD6 0xD7 0xD8 O O O O X X O O O O X 0xD9 O O 0xDA O O LED 0xD5 Intel® Server System SR1600UR TPS Description O 8h #3 X X X O 4h #2 O O O X 2h #1 X O O X LSB 1h #0 O X O X X O O X X O Trying to boot device selection 9 X O O X O X Trying to boot device selection A X O O Trying to boot device selection B Try
Intel® Server System SR1600UR TPS Appendix C: POST Code Errors Whenever possible, the BIOS displays the current boot progress codes on the video screen. Progress codes are 32-bit quantities plus optional data. The 32-bit numbers include class, subclass, and operation information. The class and subclass fields point to the type of hardware that is being initialized. The operation field represents the specific initialization activity.
Appendix C: POST Code Errors Intel® Server System SR1600UR TPS Table 48. POST Error Messages and Handling Error Code 0012 0048 0108 0109 0113 0140 0141 0146 0192 0194 0195 0196 0197 0198 019F 5220 5221 5224 8110 8111 8120 8121 8130 8131 8140 8141 8160 8161 8170 8171 8180 8181 8190 8198 8300 84F2 74 Error Message Response CMOS date/time not set Password check failed Keyboard component encountered a locked error. Keyboard component encountered a stuck key error.
Intel® Server System SR1600UR TPS Error Code 84F3 84F4 84FF 8500 8520 8521 8522 8523 8524 8525 8526 8527 8528 8529 852A 852B 852C 852D 852E 852F 8540 8541 8542 8543 8544 8545 8546 8547 8548 8549 854A 854B 854C 854D 854E 854F 8560 8561 8562 8563 8564 Revision 1.8 Appendix C: POST Code Errors Error Message Integrated Baseboard Management Controller in update mode Sensor data record empty System event log full Memory component could not be configured in the selected RAS mode.
Appendix C: POST Code Errors Error Code 8565 8566 8567 8568 8569 856A 856B 856C 856D 856E 856F 8580 8581 8582 8583 8584 8585 8586 8587 8588 8589 858A 858B 858C 858D 858E 858F 85A0 85A1 85A2 85A3 85A4 85A5 85A6 85A7 85A8 85A9 85AA 85AB 85AC 85AD 76 Intel® Server System SR1600UR TPS Error Message Response DIMM_B2 Component encountered a Serial Presence Detection (SPD) fail error. DIMM_B3 Component encountered a Serial Presence Detection (SPD) fail error.
Intel® Server System SR1600UR TPS Error Code 85AE 85AF 8601 8602 8603 8604 9000 9223 9226 9243 9246 9266 9268 9269 9286 9287 9288 92A3 92A9 92C6 92C7 92C8 94C6 94C9 9506 95A6 95A7 95A8 9609 9641 9667 9687 96A7 96AB 96E7 0xA022 0xA027 0xA028 0xA421 0xA500 0xA501 Revision 1.8 Appendix C: POST Code Errors Error Message DIMM_D3 Uncorrectable ECC error encountered. DIMM_D4 Uncorrectable ECC error encountered.
Appendix C: POST Code Errors Error Code 0xA5A0 0xA5A1 0xA5A4 0xA6A0 78 Intel® Server System SR1600UR TPS Error Message Response PCI Express* component encountered a PERR error. PCI Express* component encountered a SERR error. PCI Express* IBIST error. DXE boot services driver Not enough memory available to shadow a legacy option ROM. Intel order number E45725-010 Revision 1.
Intel® Server System SR1600UR TPS Appendix C: POST Code Errors POST Error Beep Codes The following table lists the POST error beep codes. Prior to system video initialization, the BIOS uses these beep codes to inform users on error conditions. The beep code is followed by a user-visible code on the POST Progress LEDs. For complete details, refer to the Intel® S5500/S5520 Server Board Family BIOS External Product Specification. Table 49.
Glossary Intel® Server System SR1600UR TPS Glossary Word/Acronym ACA Definition Australian Communication Authority ANSI American National Standards Institute BMC Baseboard Management Controller BIOS Basic Input/Output System CMOS Complementary Metal-oxide-semiconductor D2D DC-to-DC EMP Emergency Management Port FP Front Panel FRB Fault Resilient Boot FRU Field Replaceable Unit 2 IC Inter-integrated Circuit bus LCD Liquid Crystal Display LPC Low-pin Count LSB Least Significant B
Intel® Server System SR1600UR TPS Reference Documents Reference Documents See the following documents for additional information: Intel® Server Board S5520UR Technical Product Specification ® Intel Server System SR1600UR AC Power Supply Module Specification Intel® Server Board S5520UR/Intel® Server System SR1600UR Spares/Parts List and Configuration Guide Intel® Server System SR1600UR Service Guide Intel® S5500/S5520 Server Board Family BIOS External Product Specification Intel® Server System