Quick Start Guide Page 2
Side 2
15
Install Second Power
Supply Module (optional)
Use the 'finger hole'
to remove the filler
panel.
To remove a power supply
module, push the green latch
in the direction shown while
pulling out of the system by
the handle.
Insert the power
supply module into
the power supply
cage and push all the
way until it clicks
into place.
A
B
Handle
PS Latch
Finger
Hole
14
Tape Drive
2.5 Inch
Fixed Drive
Install
Additional
Drives
(optional)
See the Service Guide for
instructions on installing an
optional tape drive, or two
additional 2.5 inch fixed drives.
18
Install Add-in Card(s)
A
B
Open rear retention clip by pushing blue
slide upward and rotating clip fully open.
Open front retention clip by pushing the
blue latch in the direction shown and
rotating clip 90 degrees outward.
C
Remove filler panel from the selected
add-in card slot.
D
Insert add-in card until it seats in the
riser connector.
E
Close both retention clips. Note: Make
sure that all empty add-in card slots
have filler panels installed.
• Full-height Side of PCI Riser Shown
Note: Add-in card install
sequence for low-profile add-in
cards on opposite side of PCI
riser is the same.
REMOVE Filler Panel
B
A
C
D
CAUTION:
Observe normal
ESD precautions
when installing add-in cards.
A complete list of accessories and spares can be found at: http://support.intel.com/support/motherboards/server/s5520ur/
Front Panel Controls and Indicators
Intel® Local Control Panel Standard Control Panel
O M L K J HIN G
C
D
E
F
BA
J IK
BA F G HEDC
A NIC2 Activity LED
B. NIC1 Activity LED
C. Power/Sleep Button
D. Power/Sleep LED
E. Hard Drive
Activity LED
F. Status LED
G. System ID LED
H. System ID
Button
I. Reset
Button
J. USB 1.1
Port
K. NMI
(recessed)
Button
L. Video
A USB 1.1 Port
B. LCD Display
C. Menu Control Button - Up
D. Menu Control Button - Down
E. Menu Control Button - Left
F. Menu Control Button - Enter
G. ID LED
H. Power/Sleep LED
I. Power/Sleep Button
J. System Status
LED
K. NIC 2 Activity
LED
L. NIC 1 Activity LED
M. HDD Activity LED
N. Reset Button
O. USB 1.1 Port
11
Check RAID BBU
Battery Connection
Install RAID Battery Backup Unit
(BBU) (optional)
Install Intel® RAID Activation Key
and RAID Mini DIMM (optional)
Insert the Intel
®
RAID Activation Key into the midplane board
socket as shown. Make sure the key snaps into the socket.
A
Open RAID mini DIMM socket levers and insert connector
edge of mini DIMM into socket until levers close and snap
into place.
B
The RAID BBU has two hooks on
the underside. Align these hooks
with the matching chassis tabs,
then slide toward the power supply
to lock into place.
A
Connect the power cable between
the BBU and the midplane
board as shown.
Note: Backplane not
shown for clarity.
B
A
B
Midplane RAID
BBU Connector
Chassis
Tab(2)
Power
Supply
Battery
Backup
Unit
The RAID BBU has an internal
battery power cable. Open the
BBU case lid as shown.
A
If the battery power cable is not
connected,
connect the cable now.
Close and latch the BBU case lid.
B
A
B
Backplane Board not shown for clarity
Intel
®
RAID
Activation
Key Socket
RAID Mini DIMM
Socket
RAID Mini DIMM
RAID
Key
Open Levers
B
A
Midplane
Board
19
Install PCI Add-in Card Riser Assembly
Position the riser card edge
connector over the
server board riser
socket and align
the three hooks
in the riser with
the slots at
the back
of the
chassis.
To install the riser assembly:
A
Press down uniformly until the three
hooks on the rear of the PCI riser assembly
engage the chassis back panel slots.
The riser card will seat into the matching
socket on the server board.
B
Note: The PCI riser assembly
includes an intrusion switch that
engages the system cover.
Do not use the intrusion header
located on the server board.
Intrusion
Switch
Chassis Back Panel
Hook (3)
Riser
Socket
PCI
Riser
Assembly
B
Slot (3)
Riser Card
Connector
Server Board
Riser Socket
Hooks (3)
A
13
Install Optical Device
Insert the optical drive
into chassis opening and push
all the way until it stops.
B
Install the plastic guide
onto the back of the
drive and attach with
two screws as shown.
A
A
IMPORTANT NOTE: If you do not install a device at this location,
install the optical device bay filler panel shown below. This is
required to maintain proper system cooling.
B
Optical
Drive
22
Install Bezel
(optional)
Select the bezel that matches your control
panel and install as shown.
Standard Control
Panel Bezel
Intel® Local Control
Panel Bezel
Hard
Disk
Drive
Install Active System Components...for a Passive System, skip this step
23
Install Top Cover
Place top cover onto the chassis and
slide forward to engage recessed edge
at front of cover.
A
Install security screw. Note that
security screw re-installation is optional.
B
A
B
21
Install
Rack
Handles
Note: Rack handles are
required to install the bezel.
For detailed instructions,
see the Service Guide.
F
Document Type
Available Documents
Technical Product Specification
Spares, Parts List, and Configuration Guide
Software and Drivers
Content
In-depth technical information
Supported accessories and spares list
Tested peripherals and operating systems list
Tested memory list
Supported processors list
Up-to-date firmware, driver, and utility information
Server Configurator Tool
These documents can be found at:
http://support.intel.com/support/motherboards/server/s5520ur/
17
Replacing the Riser Card (optional)
A
B
Push back on the blue riser lever.
While holding the lever back, slide the
card firmly in the direction shown to
disengage the riser pins and remove
the riser card.
Remove the riser card
C
D
Push back and hold the blue lever
in that position.
Place the riser card onto
the retention pins.
E
Slide the riser card in the
direction shown to lock
it into place.
Release the blue riser
lever.
Install the replacement riser card
Riser Card
A
Blue Riser Lever
Riser Retention Pin
C
D
E
B
16
Install
Processor
Air Duct
Use care to avoid pinching system cables.
Processor
Air Duct
Install processor
air duct as
shown making
sure the front
edge of the duct
contacts the
fan module.
12
Install Hard Drives/Carriers
Remove the drive
carrier by pressing the
green latch to unlock.
Repeat these steps for each installed hard drive
Note: Carrier lever must be held in the FULLY
OPEN position to install into the chassis. Slide
carrier into chassis until it clicks, then close the
lever.
A
Pull out on the black
lever and slide the
carrier out.
B
Remove the plastic air baffle and
save for future use.
C
Install the hard disk drive
as shown.
D
Install hard disk drive assembly
into the chassis opening.
E
CAUTION: If you install less than eight
drives or devices, empty drive bays must
be occupied by carriers with baffles or with
a filler panel provided for drive locations 6
and 7 to maintain proper system cooling.
Drive 0 Primary
Hard Drive Numbering Diagram
Attach with
four screws.
D
Remove only when
installing hard drive device.
Keep for future use
C
B
31
2
4
0
5
6
7
E
A
20
Install Intel® Local Control Panel (optional)
Press the blue locking lever and
push forward to release the control
panel from the chassis.
B
Disconnect the two cables from
the back side of the backplane.
A
Slide control panel fully into chassis until the
locking lever engages.
F
Feed local control panel cables into chassis opening.
E
Connect the USB and data cables to the local control panel as shown.
D
Connect the two cables to the USB and
control panel connectors on the back
side of the backplane
as shown.
G
Remove Standard Control Panel Install Local Control Panel
D
B
Locking
Lever
Local
Control Panel
E
Slide the standard control panel
and cables out of the chassis.
C
Backplane
G
F
Locking
Lever
C
USB
Cable
Data
Cable
24
Finishing Up
Before installing your operating system, you must finish your system
installation, make I/O connections, and plug in AC power.
AC Power
CAUTION: This unit must
be operated with the TOP
COVER installed to ensure
proper cooling.
Video
1. Make sure the system top cover is installed.
I/O Module
Serial
Port A
Serial
Port B
Network
NIC1-2
USB 0-3
Video
Intel
®
RMM3
NIC Module
2. Install the server into the rack using the instructions provided
with the rack mounting kit.
3.
Connect your USB keyboard/mouse, video and other I/O
cables/devices as shown. Then connect the AC power cord(s).
25
Software
• BIOS, Drivers, and Operating System Installation
B. Configure your RAID Controller:
If using a RAID card, use the instructions provided
with the RAID controller. If using on-board RAID, you must activate RAID in the BIOS setup. See
the Intel
®
Server Board S5520UR Technical Product Specification for more information.
C. Install your Operating System:
Use the instructions provided with the RAID controller
and with the operating system.
D. Install Operating System Drivers:
With the operating system running, insert the
Intel
®
Server Deployment Toolkit CD. If using a Microsoft Windows* operating system, the
Express Installer will autorun and allow you to select the appropriate drivers to install. On other
operating systems, browse the CD folders to locate and install the driver files.
A. Update the System Software:
1. Boot from the Intel
®
Server Deployment Toolkit CD.
2. Use the Wizard to access the latest versions on the Internet and update the BIOS, firmware,
FRUSDRs, and Intel
®
RMM3. Note: You may also used downloaded files on a USB key.
E. Install Intel
®
System Management Software (optional):
Download the latest version of the Intel
®
System Management Software from
http://www.intel.com/go/servermanagement and use the instructions provided at that link to install
the software.
Intel® Server Board S5520UR
Component Layout
See your Intel
®
Server System
SR2600UR/
SR2625UR
Service Guide
for expanded
component and
connection
information.
Diag.
LEDs
USB
8, 9
USB
2, 5
Video
ID LED
Serial A
CPU 1
I/O Exp.
Module Conn. 1
I/O Exp.
Module Conn. 2
SGPIO
SATA Key
LCP/AUX IPMB
BMC Force
Update
Front USB
SSD
USB
Power
Supply
Signal
Conn.
Serial B
SATA 5
SATA 0
SATA 1
SATA 2
SATA 3
SATA 4
CPU 2
Fan
Mem 2
Fan
CPU
Power
Front
Panel
CPU 2
Bridge Board Conn.
Sys 1
Fan
Sys 2
Fan
NIC1
NIC2
DIMM A2
DIMM C1
DIMM A1
DIMM B2
DIMM B1
DIMM C2
Main Power
Fan Board
DIMM Status LEDs
Battery
DIMM F1
DIMM D2
DIMM F2
DIMM E1
DIMM E2
DIMM D1
PCIe* Riser
RMM3 Conn.
DIMM
Status
LEDs
CPU 1 Fan
Mem 1 Fan
Status
LED
BIOS
Recover
Password
Clear
BIOS
Default
Serial Port
Config.
AXXHERAIL2
Cable Management Arm
Tool-less Rail Kit
AXXBASRAIL13
Basic Slide Rail Kit
ADRBEZBLACK
Bezel for Standard Control Panel
Optional Accessories and Order Codes
AXXBRACKETS
AXXRACKARM2
Fixed Rack Brackets
ADRLCDBEZEL
Intel
®
Remote Management Module 3
Bezel for Intel
®
Local Control Panel
AXXRMM3
AXXSATADVDROM
Slimline DVD-ROM/CD-ROM Drive
ASR2600FIXDRV
Fixed 2.5 inch Drive Mounting Kit
ASR2500SATAPE
SAS/SATA Tape Drive Mounting Kit
AXXLCPRACK2
Intel
®
Local Control Panel Module
AXX750WPS
750-W Power Supply
Infiniband* I/O Expansion Module
AXXGBIOMOD
Dual Gigabit I/O Expansion Module
AXXSASIOMOD
AXX4GBIOMOD2
AXX10GBIOMOD
SAS I/O Expansion Module
Quad-Port Gigabit I/O Expansion Module
10 Gigabit I/O Expansion Module
AXXRAKSAS2
RAID Mini DIMM
RAID Activation Key
AXXMINIDIMM512
AXXIBIOMOD