Intel® Server System SR2612UR Technical Product Specification Intel order number E76293-003 Revision 1.
Revision History Intel® Server System SR2612UR TPS Revision History Date July 2009 Revision Number 1.0 Modifications July 2009 1.1 Updated Regulatory and Certification Information and Added PMBus Information. November 2009 1.2 Updated section 4.5 with correct SATA HDD support information. April 2010 1.3 Updated Section 5.2.1 Hard Drive Activity and Fault LEDs. Removed CCC certification in section 10. Initial Release.
Intel® Server System SR2612UR TPS Table of Contents Table of Contents 1. Introduction ........................................................................................................................1 1.1 Chapter Outline ......................................................................................................1 1.2 Server Board Use Disclaimer .................................................................................1 2. Product Overview .......................................
Table of Contents Intel® Server System SR2612UR TPS 3.8.2 Over-voltage Protection (OVP) .............................................................................23 3.8.3 Over-temperature Protection (OTP) .....................................................................23 3.9 DC Output Specification .......................................................................................24 3.9.1 Output Power/Currents .............................................................................
Intel® Server System SR2612UR TPS 8.2 Table of Contents PCI Riser Card Mechanical Drawings ..................................................................46 9. Environmental Specifications .........................................................................................49 9.1 System Level Environmental Limits ......................................................................49 9.2 Serviceability and Availability...........................................................................
List of Figures Intel® Server System SR2612UR TPS List of Figures Figure 1. Top Down View ............................................................................................................6 Figure 2. System Width ..............................................................................................................7 Figure 3. System Length .............................................................................................................7 Figure 4.
Intel® Server System SR2612UR TPS List of Figures Figure 33. 2U Butterfly PCI Express* Active Riser – Secondary Side ....................................... 48 Figure 34. Diagnostic LED Placement Diagram ........................................................................62 vii Revision 1.
List of Tables Intel® Server System SR2612UR TPS List of Tables Table 1. System Feature Set ......................................................................................................2 Table 2. Mixed Processor Configurations....................................................................................4 Table 3. System Dimensions ......................................................................................................6 Table 4. Drive Overview ..................................
Intel® Server System SR2612UR TPS List of Tables Table 32. Time Estimate for System Maintenance Procedures ................................................. 49 Table 33. POST Progress Code LED Example .........................................................................62 Table 34. Diagnostic LED POST Code Decoder .......................................................................63 Table 35. POST Error Messages and Handling ........................................................................
Intel® Server System SR2612UR TPS 1. Introduction Introduction This Technical Product Specification (TPS) provides system-specific information detailing the features, functionality, and high-level architecture of the Intel® Server System SR2612UR. You can also reference the Intel® Server Board S5520UR Technical Product Specification to obtain greater detail of functionality and architecture specific to the integrated server board and learn about what is supported on this server system.
Product Overview 2. Intel® Server System SR2612UR TPS Product Overview The Intel® Server System SR2612UR is a rack mount 2U server system integrated with an Intel® Server Board S5520UR with features designed to support the high-density high performance computing server market. This chapter provides a high-level overview of the system features. The following chapters provide greater detail for each major system component or feature. Table 1.
Intel® Server System SR2612UR TPS Feature LEDs and displays Product Overview Description Power LED Standby Power LED ( +3.
Product Overview Intel® Server System SR2612UR TPS When using a single processor configuration, you must install the processor into the processor socket labeled CPU1. A terminator is not required in the second processor socket when using a single processor configuration. When two processors are installed, the following population rules apply: Both processors must be of the same processor family. Both processors must have the same front-side bus (FSB) speed.
Intel® Server System SR2612UR TPS Product Overview Error Processor frequency (speed) not identical Severity Major System Action The BIOS detects the error condition and responds as follows: Adjusts all processor frequencies to lowest common denominator. Continues to boot the system successfully. If the frequencies for all processors cannot be adjusted to be the same, then the BIOS: Logs the error into the SEL. Displays “0197: Processor speeds mismatched” message in the error manager.
Product Overview 2.2 Intel® Server System SR2612UR TPS System Overview Figure 1. Top Down View 2.3 System Dimensions Table 3. System Dimensions Height 87 mm 3.43 in Width 446 mm 17.57 in 781.5 mm 30.79 in 812.4 mm 32.01 in 30.3 kg 67 lbs Depth Rack Mounting Surface to Rear IO/Tray Module Handle Depth Front Surface of Disk Drive to Rear IO/Tray Module Handle Maximum Weight 6 Revision 1.
Intel® Server System SR2612UR TPS Product Overview Figure 2. System Width Figure 3. System Length 7 Revision 1.
Product Overview 2.4 Intel® Server System SR2612UR TPS System Components A. Rack Mount Ears and Handles E. RAID Controller Card BBU (Optional) B. Active SAS Midplane F. CPU / Memory Air Duct C. System Fans Assembly G. PCI Riser Card Assembly D. Power Distribution Board Figure 4. Major System Components (1 of 2) 8 Revision 1.
Intel® Server System SR2612UR TPS H. Hot-swap SAS/SATA Hard Drive Backplane Product Overview I. Cable Retention Assembly Figure 5. Major System Components (2 of 2) 9 Revision 1.
Product Overview 2.5 Intel® Server System SR2612UR TPS Hard Drive and Peripheral Bays The system is designed to support several different hard drive and peripheral configurations. The system includes a hot-swap twelve-bay backplane capable of supporting either SAS or SATA drives. You can optionally configure the internal 2.5-inch SATA hard drive bay to support two fixed 2.5-inch hard drives. A. Hot-swap 3.5-inch Hard Drive Bays (12) B. Front LEDs Board C. Internal fixed 2.
Intel® Server System SR2612UR TPS Product Overview Table 4. Drive Overview Slimline SATA Optical Drive Slimline USB Floppy Drive SATA Drives SAS Drives Product Code – SR2612UR Supported Not Supported Up to 12 hot-swap 3.5-inch drives plus two fixed 2.5-inch drives inside chassis Up to 12 hot-swap 3.5-inch drives 11 Revision 1.
Product Overview 2.6 Intel® Server System SR2612UR TPS System Board Overview ® Figure 7. Intel Server Board S5520UR The following figure shows the board layout of the server board. Each connector and major component is identified by a number or letter, and a description is given below the figure. 12 Revision 1.
Intel® Server System SR2612UR TPS Product Overview ® Figure 8. Intel Server Board S5520UR Components 13 Revision 1.
Product Overview Intel® Server System SR2612UR TPS Table 5.
Intel® Server System SR2612UR TPS Product Overview A POST Code Diagnostic LEDs F CPU 1 DIMM Fault LEDs B System Identification LED G CPU 2 Fan Fault LED C Status LED H Memory 2 Fan Fault LED D Memory 1 Fan Fault LED I CPU 2 DIMM Fault LEDs E CPU 1 Fan Fault LED J 5V Standby LED ® Figure 10. Intel Light-Guided Diagnostic LEDs - Server Board 2.7 Rack and Cabinet Mounting Options The system is designed to support 19 inches wide by up to 34 inches deep server cabinets.
Cooling Subsystem 3. Intel® Server System SR2612UR TPS Power Subsystem The power subsystem of the system consists of an integrated Power Distribution Module (PDM), power module enclosure, and support for up to two 760-Watt power supply modules. You can configure the power subsystem to support dual modules in a 1+1 redundant power configuration. In a 1+1 configuration, you can hot-swap a single failed power module with the system running.
Intel® Server System SR2612UR TPS 3.1 Cooling Subsystem Mechanical Overview The following figures display the Power Distribution Module and the Power Supply Module dimensions. Figure 13. Mechanical Drawing for Power Supply Module Figure 14. Mechanical Drawing for Power Distribution Module 17 Revision 1.
Cooling Subsystem 3.2 Intel® Server System SR2612UR TPS Handle and Retention Mechanism Each power supply module includes a handle for module insertion to or removal from the module enclosure. Each module has a simple retention mechanism to hold the power module in place once it is inserted. This mechanism withstands the specified platform mechanical shock and vibration requirements. The tab on the retention mechanism is colored green to indicate it is a hot-swap touch point.
Intel® Server System SR2612UR TPS 3.6 Cooling Subsystem Output Connectors The power distribution board provides a cable harness providing connectors to the various system boards. The harness size, connectors, and pin outs are shown in the following tables. Listed or recognized component appliance wiring material (AVLV2), CN, rated 105°C minimum, 300 VDC minimum is used for all output wiring. Table 7.
Cooling Subsystem Intel® Server System SR2612UR TPS Contact: Molex Mini-Fit, HCS, Female, Crimp 44476 or equivalent Table 9. P2 Main Power Connector Pin 1 2 3 4 5 Signals +3.3 VDC +3.3 VDC COM (GND) 5 VDC COM 18 AWG Color Orange Orange Black Red Black Pin 13 14 15 16 17 +3.3 VDC -12 VDC COM PS_ON# COM 18 AWG Colors Orange Blue Black Green Black 6 +5 VDC Red 18 COM Black 7 8 9 10 11 12 COM PWR OK 5 VSB +12 V3 +12 V3 +3.
Intel® Server System SR2612UR TPS 10 11 12 3.6.5 +12V +12V +3.3V Cooling Subsystem Yellow Yellow Orange 22 23 24 +5V +5V GND Red Red Black P5 and P6– Auxiliary Baseboard Power Connector Connector housing: 4-Pin Molex* 39-01-2040 or equivalent Contact: Molex* 44476-1111 or equivalent Table 12. P5 and P6 Auxiliary Baseboard Power Connector Pin 1 2 3.6.
Cooling Subsystem Intel® Server System SR2612UR TPS Table 15. AC Input Rating Parameter Line Voltage (110) Line Voltage (220) Frequency Minimu m Rated Maximu m 90 Vrms 100 - 127 Vrms 140 Vrms 180 Vrms 200 - 240 Vrms 264 Vrms 47 Hz 50/60 Hz 63 Hz Notes: 1. The maximum input line current shall be less than 9.0 Amps RMS at 100VAC when measured under the standard test condition 3.7.
Intel® Server System SR2612UR TPS Cooling Subsystem The DC/DC converters are not damaged from repeated power cycling in this condition. The +12 V output from the power supply is divided on the PDB into four channels and each is limited to 240 VA of power. If the limit is exceeded, current sensors and limit circuits shut down the entire PS and PDB. The following table lists the limits. Table 16. Over-current Protection Limits / 240 VA Protection Output Voltage +3.
Cooling Subsystem 3.9 3.9.1 Intel® Server System SR2612UR TPS DC Output Specification Output Power/Currents The following table defines power and current ratings for this 750-W continuous (860 W pk) power supply in 1+0 or 1+1 redundant configuration. The combined output power of both outputs does not exceed the rated output power. The power supply must meet both static and dynamic voltage regulation requirements for the minimum loading conditions.
Intel® Server System SR2612UR TPS 3.10.2 Cooling Subsystem Data Format The data format for current, voltage, power, temperature, and fan speed are using the PMBus Literal format. Literal data format: X = Y · 2N X = the sensor value in volts, amps, watts, degrees C, or RPM Y = mantissa. The mantissa is the variable components that changes as the sensor value changes. Y is a 16-bit unsigned value for the READ_VOUT command. For all other READ commands, Y is an 11-bit signed 2’s compliment value.
Cooling Subsystem 3.10.5 Intel® Server System SR2612UR TPS Capability and inventory reporting The follow commands are supported for discovery of the power supplies capabilities. Command Meaning CAPABILITY Defines the power supplies PEC support, bus speed, and support of SMBAlert. QUERY Defines the power supplies PEC support, bus speed, and support of SMBAlert. PAGE The PAGE command is used to QUERY a specific output of a multi-output power supply. 3.10.5.
Intel® Server System SR2612UR TPS 4. Cooling Subsystem Cooling Subsystem Several components and configuration requirements make up the cooling subsystem of the system. These include the system fan module, power supply fans, CPU air duct, and drive bay population. All are necessary to provide and regulate the airflow and air pressure needed to maintain the system’s thermals when operating at or below the maximum specified thermal limits.
Cooling Subsystem Intel® Server System SR2612UR TPS Figure 15. Airflow Paths 4.2 System Fan Module 28 Revision 1.
Intel® Server System SR2612UR TPS Cooling Subsystem A: Foam Insertion for Cable Retention Figure 16. Non-redundant Fan Module The system fan module, which includes four non-redundant 80-mm fans, is designed for ease of use and supports several management features that the Integrated Baseboard Management Controller can use. The system fans plug into headers on the server board. Each fan within the module is capable of supporting multiple speeds.
Cooling Subsystem Intel® Server System SR2612UR TPS Table 20. Non-redundant Fan Connector Pin Assingment Pin 1 2 3 4 4.3 Signal Name Return 12V FOO PWM Description Return path to ground Power for fan Fan Tachometer signal Fan speed control signal Airflow Support Table 21.
Intel® Server System SR2612UR TPS Cooling Subsystem Figure 18. 3.5-inch Drive Carrier with a Blank 4.5 Sata HDD Support The maximum supported temperatures when using SATA drives are affected as follows: • At 1500 m (5000 ft), the maximum ambient temperature is 25°C. • At 300 m (1000 ft), the maximum ambient temperature is 35°C. 31 Revision 1.
System Board Interconnects 5. Intel® Server System SR2612UR TPS System Board Interconnects System boards within the system include the midplane, bridge board, hot-swap backplane, and control panel. This chapter describes the interconnect features of each and defines the pin-outs for each connector. Later chapters describe functional details of each system board. 5.1 Active SAS Midplane The midplane is designed around a PMC8388 24-port SAS expander.
Intel® Server System SR2612UR TPS System Board Interconnects Table 22. SAS Connector Pin-out (J2) 5.
System Board Interconnects Intel® Server System SR2612UR TPS A. SAS/SATA Hard Disk Drive Connectors Figure 20. 3.5-inch Hot-swap SAS/SATA Backplane (Front Side View) A. Backplane Power Connector B. Motherboard/Midplane GPIO Connector C. Midplane Board Connector Figure 21. 3.5-inch Hot-swap SAS/SATA Backplane (Back Side View) The following tables define the connector pin-outs for backplane board. Table 23.
Intel® Server System SR2612UR TPS System Board Interconnects Table 24. Backplane Power Supply Pin-out (J23) Pin Signal Pin Signal 1 +3.3V 13 +3.3V 2 +3.3V 14 +12V 3 GND 15 GND 4 +5V 16 GND 5 GND 17 GND 6 +5V 18 GND 7 GND 19 GND 8 +12V 20 +12V 9 Fan Power (+12V) 21 +5V 10 Fan Power (+12V) 22 +5V 11 +12V 23 +5V 12 +3.3V 24 GND Table 25. SAS/SATA Hard Drive Connector Pin-outs (J1, J2, …, J12) Pin Signal Pin Signal 1 GND 17 +3.
System Board Interconnects Intel® Server System SR2612UR TPS Table 26. Hard Drive LED Function Definitions LED Function 1. Not Used 2. 3.
Intel® Server System SR2612UR TPS 5.3 System Board Interconnects Remote RAID Controller Battery Backup Unit Mount Figure 22. Remote RAID BBU Mount The space is provided to mount a remote Battery Backup Unit (BBU) for a hardware RAID controller car. This mount point ensures the BBU is attached correctly to chassis ground and is located in an area of enclosure that ensures correct BBU cooling. 37 Revision 1.
Peripheral and Hard Drive Subsystem 6. Intel® Server System SR2612UR TPS Peripheral and Hard Drive Subsystem You can configure the system to support several different hard drive and peripheral configurations. The peripheral/hard drive subsystem consists of a drive bay supporting a slimline optical drive, hard drives, and a flex bay; a midplane; and a hot-swap backplane. This chapter describes the details for each subsystem component. A. Hot-Swap 3.5-inch Hard Drive Bays (12) B. Internal fixed 2.
Intel® Server System SR2612UR TPS Peripheral and Hard Drive Subsystem Figure 23. Drive Bay Overview 6.1 Slimline Optical Drive Bay The system provides a slimline drive bay designed to support a single slimline SATA optical drive. For a list of supported drives, refer to the Server Configurator Tool available at: http://serverconfigurator.intel.com/default.aspx The optical drive is mounted to a tool-less assembly latch that allows for easy installation and attachment to the system.
Peripheral and Hard Drive Subsystem Intel® Server System SR2612UR TPS A. Hard Drive B. Hard Drive Connector C. Mounting Screw D. Side Rail E. Drive Carrier Figure 25. 3.5-inch Hard Drive Tray Assembly 40 Revision 1.
Intel® Server System SR2612UR TPS 7. Control Panel Control Panel The Intel® Server System SR2612UR provides one front LED panel and one rear control panel. Both front LED panel and rear control panel provide LEDs for monitoring system status, and the rear control panel supports power button. Control panels from previous server generations or other server platforms are not compatible with the Intel® Server System SR2612UR. 7.1 Front LED Panel The front LED panel houses several status LEDs.
Control Panel Intel® Server System SR2612UR TPS LED System Identify LED 7.2 Color Blue Function The initial state of this LED is off. This blue ID LED can be illuminated by server system management software. Rear Control Panel The rear control panel houses the power switch and four status LEDs to display the system’s operating state. The following table defines the rear control panel’s LED functionalities. Figure 27. Rear Control Panel Table 28.
Intel® Server System SR2612UR TPS Color State Control Panel Criticality Description Color State Criticality Correctable errors over a threshold of ten and migrating to a spare DIMM (memory sparing). This indicates that the user no longer has spare DIMMs specifying a redundancy lost condition. The corresponding DIMM LED should light up. In a mirrored configuration, when memory mirroring takes place and system loses memory redundancy. This is not covered by the previous bullet.
PCI Riser Cards and Assembly 8. Intel® Server System SR2612UR TPS PCI Riser Cards and Assembly The system supports different riser card options depending on the add-in card configuration desired. The riser assembly for the system is tool-less. Standoffs on the bracket allow the riser cards to slide onto the assembly where a latching mechanism secures each riser in place. Holding down the latch releases the risers for easy removal. Figure 28.
Intel® Server System SR2612UR TPS PCI Riser Cards and Assembly Figure 29. 2U PCI Express* Passive Riser 8.1 Riser Card Options The Intel® Server Board S5520UR has one riser slot capable of supporting riser cards for both 1U and 2U system configurations. The riser slot (J4E1) implements Intel® Adaptive Slot Technology. This 280-pin connector is capable of supporting riser cards that meet either the PCI-X or PCI Express* technology specifications.
PCI Riser Cards and Assembly 8.2 Intel® Server System SR2612UR TPS PCI Riser Card Mechanical Drawings Figure 30. 2U PCI Express* Passive Riser – Primary Side 46 Revision 1.
Intel® Server System SR2612UR TPS PCI Riser Cards and Assembly Figure 31. 2U PCI Express* Passive Riser – Secondary Side 47 Revision 1.
PCI Riser Cards and Assembly Intel® Server System SR2612UR TPS Figure 32. 2U Butterfly PCI Express* Active Riser – Primary Side Figure 33. 2U Butterfly PCI Express* Active Riser – Secondary Side 48 Revision 1.
Intel® Server System SR2612UR TPS Environmental Specifications 9. Environmental Specifications 9.1 System Level Environmental Limits The following table defines the system level operating and non-operating environmental limits. Table 31. System Environmental Limits Summary Parameter Operating Temperature Non-Operating Temperature Non-Operating Humidity Acoustic noise Shock, operating Shock, unpackaged Shock, packaged Vibration, unpackaged ESD System Cooling Requirement in BTU/Hr 9.
Environmental Specifications Intel® Server System SR2612UR TPS WARNING Danger of explosion if batter y is incor r ectly r eplaced. Replace only with the same or equivalent type r ecommended by the equipment manufactur er . Discar d used batter ies accor ding to manufactur er ’s instr uctions. ADVARSEL! Lithiumbatter i - Eksplosionsfar e ved fejlagtig håndter ing. Udskiftning må kun ske med batter i af samme fabr ikat og type. Levér det br ugte batter i tilbage til lever andør en.
Intel® Server System SR2612UR TPS Regulatory and Certification Information 10. Regulatory and Certification Information WARNING To ensure regulatory compliance, you must adhere to the assembly instructions in this document to ensure and maintain compliance with existing product certifications and approvals. Use only the described, regulated components specified in this document.
Regulatory and Certification Information 10.1.2 10.1.
Intel® Server System SR2612UR TPS WEEE Directive (2002/96/EC) EU Packaging Directive (94/62/EC) All plastic parts that weigh >25gm shall be marked with the ISO11469 requirements for recycling. Example >PC/ABS< 10.1.
Regulatory and Certification Information Regulatory Compliance IRAM Mark Country Argentina Ctick Mark Australia / NZ Intel® Server System SR2612UR TPS Marking N232 Country of Origin Mark Made in China FCC Marking (Class A) USA EMC Marking (Class A) Canada VCCI Marking (Class A) Japan BSMI Certification Number & Class A Warning Taiwan This device complies with Part 15 of the FCC Rules.
Intel® Server System SR2612UR TPS Regulatory and Certification Information Regulatory Compliance Waste of Electronic and Electrical Equipment Recycling Mark Country Europe Marking China Restriction of Hazardous Substance Environmental Friendly Use Period Mark China China Recycling Mark China Recycling Marks International Battery Perchlorate Warning Information California Perchlorate Material – Special handling may apply. See www.dtsc.ca.
Regulatory and Certification Information Regulatory Compliance Safety Intel® Server System SR2612UR TPS Country Standard icon for Power button Marking 10.3 Rack Mount Installation Guidelines Anchor the equipment rack: The equipment rack must be anchored to an unmovable support to prevent it from falling over when one or more servers are extended in front of the rack on slides. You must also consider the weight of any other device installed in the rack.
Intel® Server System SR2612UR TPS Regulatory and Certification Information be labeled as controlling power to the server. The circuit breaker of a centralized DC power system may be used as a disconnect device when easily accessible and should be rated no more than 10 amps. Grounding the server: To avoid the potential for an electrical shock hazard, you must reliably connect an earth grounding conductor to the server.
Regulatory and Certification Information Intel® Server System SR2612UR TPS Intel Corporation 5200 N.E. Elam Young Parkway Hillsboro, OR 97124-6497 1-800-628-8686 This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
Intel® Server System SR2612UR TPS 10.5.3 Regulatory and Certification Information Europe (CE Declaration of Conformity) This product has been tested in accordance too, and complies with the Low Voltage Directive (73/23/EEC) and EMC Directive (89/336/EEC). The product has been marked with the CE Mark to illustrate its compliance. 10.5.
Regulatory and Certification Information Intel® Server System SR2612UR TPS 5. Manufacturer/Nation: Intel Corporation/Refer to country of origin marked on product 10.6 Regulated Specified Components To maintain the UL listing and compliance to other regulatory certifications and/or declarations, the following regulated components must be used and conditions adhered to. Interchanging or use of other component will void the UL listing and other product certifications and approvals.
Intel® Server System SR2612UR TPS Appendix A: Integration and Usage Tips Appendix A: Integration and Usage Tips This section provides a list of useful information unique to the Intel® Server System SR2612UR and should be kept in mind while integrating and configuring your Intel® Server Board S5520UR. Only low-profile (1.2 in or 30.48 mm) DIMMs can be used in the server system. Processor fans are not supported and are not needed in the server system.
Appendix B: POST Code Diagnostic LED Decoder Intel® Server System SR2612UR TPS Appendix B: POST Code Diagnostic LED Decoder During the system boot process, the BIOS executes a number of platform configuration processes, each of which is assigned a specific hex POST code number. As each configuration routine is started, the BIOS displays the POST code to the POST Code Diagnostic LEDs on the back edge of the server board.
Intel® Server System SR2612UR TPS Appendix B: POST Code Diagnostic LED Decoder Table 34.
Appendix B: POST Code Diagnostic LED Decoder Intel® Server System SR2612UR TPS Diagnostic LED Decoder O = On, X=Off Checkpoint Upper Nibble Lower Nibble Description MSB LSB 8h 4h 2h 1h 8h 4h 2h 1h LED #7 #6 #5 #4 #3 #2 #1 #0 0x57h X O X O X O O O Reserved for PCI bus USB 0x58h X O X O O X X X Resetting USB bus 0x59h X O X O O X X O Reserved for USB devices ATA/ATAPI/SATA 0x5Ah X O X O O X O X Resetting SATA bus and all devices 0x5Bh X O X O O X O O Reserved for ATA SMBUS 0x5Ch X O X O O O X X Resetting SM
Intel® Server System SR2612UR TPS Appendix B: POST Code Diagnostic LED Decoder Diagnostic LED Decoder O = On, X=Off Checkpoint Upper Nibble Lower Nibble Description MSB LSB 8h 4h 2h 1h 8h 4h 2h 1h LED #7 #6 #5 #4 #3 #2 #1 #0 0xD9 O X X O Trying to boot device selection 9 O O X O 0xDA O O X O O X O X 0xDB O O X O O Trying to boot device selection A O X O O Trying to boot device selection B O O X X Trying to boot device selection C 0xDC O 0xDD O O X 0xF4h O O O O X O X
Appendix C: POST Code Errors Intel® Server System SR2612UR TPS Appendix C: POST Code Errors Whenever possible, the BIOS outputs the current boot progress codes on the video screen. Progress codes are 32-bit quantities plus optional data. The 32-bit numbers include class, subclass, and operation information. The class and subclass fields point to the type of hardware being initialized. The operation field represents the specific initialization activity.
Intel® Server System SR2612UR TPS Error Code 8140 8141 8160 8161 8170 8171 8180 8181 8190 8198 8300 84F2 84F3 84F4 84FF 8500 8520 8521 8522 8523 8524 8525 8526 8527 8528 8529 852A 852B 852C 852D 852E 852F 8540 8541 8542 8543 8544 8545 8546 8547 8548 8549 854A 854B 854C 854D 854E 854F 8560 8561 8562 8563 8564 8565 8566 8567 8568 8569 Appendix C: POST Code Errors Error Message Processor 01 Failed FRB-3 Timer. Processor 02 Failed FRB-3 Timer.
Appendix C: POST Code Errors Error Code 856A 856B 856C 856D 856E 856F 8580 8581 8582 8583 8584 8585 8586 8587 8588 8589 858A 858B 858C 858D 858E 858F 85A0 85A1 85A2 85A3 85A4 85A5 85A6 85A7 85A8 85A9 85AA 85AB 85AC 85AD 85AE 85AF 8601 8602 8603 8604 9000 9223 9226 9243 9246 9266 9268 9269 9286 9287 9288 92A3 92A9 92C6 92C7 92C8 Intel® Server System SR2612UR TPS Error Message DIMM_C3 Component encountered a Serial Presence Detection (SPD) fail error.
Intel® Server System SR2612UR TPS Error Code 94C6 94C9 9506 95A6 95A7 95A8 9609 9641 9667 9687 96A7 96AB 96E7 0xA022 0xA027 0xA028 0xA421 0xA500 0xA501 0xA5A0 0xA5A1 0xA5A4 0xA6A0 Appendix C: POST Code Errors Error Message LPC component encountered a controller error. LPC component encountered a resource conflict error. ATA/ATPI component encountered a controller error. PCI component encountered a controller error. PCI component encountered a read error. PCI component encountered a write error.
Appendix C: POST Code Errors Intel® Server System SR2612UR TPS Table 37. Integrated BMC Beep Codes Code 1-5-2-1 Reason for Beep No CPUs installed or first CPU socket is empty. Associated Sensors CPU Missing Sensor Supported Yes 1-5-4-2 Power fault: DC power unexpectedly lost (power good dropout). Power unit – power unit failure offset. Yes 1-5-4-4 Power control fault (power good assertion timeout). Power unit – soft power control failure offset. Yes 70 Revision 1.
Intel® Server System SR2612UR TPS Glossary Glossary Word / Acronym ACA Australian Communication Authority ACPI Advanced Configuration and Power Interface ANSI American National Standards Institute ATA Advanced Technology Attachment BMC Baseboard Management Controller BIOS Basic Input/Output System CMOS Complementary Metal-oxide-semiconductor D2D DC-to-DC EMC Electromagnetic Compatibility EMP Emergency Management Port ESD Electrostatic Discharge FP Front Panel FRB Fault Resilient B
Glossary Intel® Server System SR2612UR TPS Word / Acronym USB Universal Serial Bus Definition VCCI Voluntary Control Council for Interference VRD Voltage Regulator Down VSB Voltage Standby 72 Revision 1.
Intel® Server System SR2612UR TPS Reference Documents Reference Documents Refer to the following documents for additional information: Intel® Server Board S5520UR Technical Product Specification 73 Revision 1.