Technical Product Specification

Intel® Server System SR2612UR TPS Control Panel
Revision 1.3
Intel order number E76293-003
43
Color
State
Criticality
Description
Correctable errors over a threshold of ten and migrating to a
spare DIMM (memory sparing). This indicates that the user no
longer has spare DIMMs specifying a redundancy lost
condition. The corresponding DIMM LED should light up.
In a mirrored configuration, when memory mirroring takes
place and system loses memory redundancy. This is not
covered by the previous bullet.
Redundancy loss such as power supply or fan. This does not
apply to non-redundant subsystems.
PCI Express* link errors
CPU failure / disabled if there are two processors and one of
them fails.
Fan alarm Fan failure. Number of operational fans should be
more than the minimum number needed to cool the system.
Non-critical threshold crossed – temperature and voltage.
Color
State
Criticality
Description
Amber
Blink
Non-critical
Non-fatal alarm system is likely to fail
Including, but not limited to:
Critical voltage threshold crossed
VRD hot asserted
Minimum number of fans to cool the system are not present or
have failed.
In non-sparing and non-mirroring mode if the threshold of ten
correctable errors is crossed within the window.
Amber
Solid on
Critical, non-
recoverable
Fatal alarm system has failed or shut down
Including, but not limited to:
DIMM failure when there is one DIMM present and no good
memory is present.
Run-time memory uncorrectable error in non-redundant mode.
IERR signal asserted
Processor 1 missing
Temperature (for example, CPU ThermTrip, memory TempHi,
critical threshold crossed)
No power good power fault.
Processor configuration error (for example, processor stepping
mismatch)
7.4 System Identification LED
The blue system identification LED helps to identify a system for servicing. This is especially
useful when the system is installed in a high-density rack or cabinet populated with several
similar systems.
The blue system ID LED lights-up by issuing the appropriate hex IPMI system identify value, the
ID LED either blinks blue for 15 seconds and turns off or blinks indefinitely until the appropriate
hex IPMI system identify value is issued to turn it off.