Intel® Server System SR1625UR Technical Product Specification Intel order number E47487-012 Revision 2.
Revision History Intel® Server System SR1625UR TPS Revision History Date March 2009 October 2009 January 2010 April 2010 Revision Number 1.0 1.1 1.2 1.3 June 2010 1.4 August 2010 1.5 October 2010 1.6 December 2010 1.7 December 2010 April 2011 July 2011 1.8 1.9 2.0 Modifications Initial release. Updated section 9.3 - External Standard Control Panel Connectors. ® Updated section 7.2.2 - Intel IT/IR RAID. Updated section 2.5 - System Board Overview. Updated section 4.2.3 - CPU/Memory.
Intel® Server System SR1625UR Table of Contents Table of Contents 1. Introduction ........................................................................................................................1 1.1 Chapter Outline ......................................................................................................1 1.2 Server Board Use Disclaimer .................................................................................2 2. Product Overview ...........................................
Table of Contents Intel® Server System SR1625UR TPS 3.6.7 AC Line 5 VSB Holdup .........................................................................................23 3.6.8 AC Line Leakage Current .....................................................................................23 3.6.9 Power Factor Correction ......................................................................................23 3.7 DC Output Specification ...................................................................
Intel® Server System SR1625UR Table of Contents 8. Mini Control Panel Functionality .....................................................................................55 8.1 Mini Control Panel Buttons ...................................................................................55 8.2 Mini Control Panel LED Indicators ........................................................................56 8.2.1 Power/Sleep LED .................................................................................
Table of Contents Intel® Server System SR1625UR TPS 13.2 Product Regulatory Compliance Markings ...........................................................76 13.3 Rack Mount Installation Guidelines ......................................................................78 13.4 Power Cord Usage Guidelines .............................................................................79 13.5 Electromagnetic Compatibility Notices .................................................................80 13.5.
Intel® Server System SR1625UR List of Figures List of Figures Figure 1. Top Down View – Passive System Shown ...................................................................7 Figure 2. Major System Components ..........................................................................................8 Figure 3. Drive Bay Overview......................................................................................................9 Figure 4. Intel® Server Board S5520UR ....................................
List of Figures Intel® Server System SR1625UR TPS Figure 33. Hot-Swap SAS/SATA Backplane (Back Side View) ................................................. 52 Figure 34. SAS/SATA Backplane Functional Block Diagram ....................................................53 Figure 35. Mini Control Panel Assembly Module .......................................................................55 Figure 36. Mini Control Panel Buttons ...................................................................................
Intel® Server System SR1625UR List of Tables List of Tables Table 1. System Feature Set ......................................................................................................3 Table 2. Mixed Processor Configurations....................................................................................6 Table 3. System Dimensions ......................................................................................................7 Table 4. Drive Overview ......................................
List of Tables Intel® Server System SR1625UR TPS Table 33. PCI Express* x4 Slot Connector from Midplane ........................................................40 Table 34. PCI Express* x4 Slot Connector from Midplane ........................................................41 Table 35. Intel® Local Control Panel (LCP) Connector ..............................................................42 Table 36. Control Panel Signal Connector ..........................................................................
Intel® Server System SR1625UR List of Tables Table 67. POST Error Beep Codes ...........................................................................................92 Table 68. Integrated BMC Beep Codes ....................................................................................94 Revision 2.
List of Tables Intel® Server System SR1625UR TPS < This page is intentionally left blank.> xii Intel order number E47487-012 Revision 2.
Intel® Server System SR1625UR TPS 1. 0BIntroduction Introduction This Technical Product Specification (TPS) provides system-specific information detailing the features, functionality, and high-level architecture of the Intel® Server System SR1625UR. The Intel® Server Board S5520UR Technical Product Specification should also be referenced to obtain greater detail of functionality and architecture specific to the integrated server board, which is also supported on this server system.
Introduction 1.2 Intel® Server System SR1625UR TPS Server Board Use Disclaimer Intel Corporation server boards support add-in peripherals and contain a number of highdensity VLSI and power delivery components that need adequate airflow to cool. Intel ensures through its own system development and testing that when Intel server building blocks are used together, the fully integrated system will meet the intended thermal requirements of these components.
Intel® Server System SR1625UR TPS 2. 1BProduct Overview Product Overview The Intel® Server System SR1625UR is a rack mount 1U server system with features that are designed to support the high-density high-performance computing server market.
1BProduct Overview Intel® Server System SR1625UR TPS Feature Description Peripherals Slimline bay for slimline SATA optical drive. One PCI Express* X16 add-in card slot (Gen 2).
Intel® Server System SR1625UR TPS 2.1.1 1BProduct Overview Processor Population Rules Note: Although the server board does support dual-processor configurations consisting of different processors that meet the defined criteria below, Intel does not perform validation testing of this configuration. For optimal system performance in dual-processor configurations, Intel recommends that identical processors be installed.
1BProduct Overview Intel® Server System SR1625UR TPS Table 2. Mixed Processor Configurations Error Processor family not identical Severity Fatal System Action The BIOS detects the error condition and responds as follows: Logs the error into the system event log (SEL). Alerts the Integrated BMC of the configuration error with an IPMI command. Does not disable the processor. Displays “0194: Processor family mismatch detected” message in the error manager. Halts the system.
Intel® Server System SR1625UR TPS 2.2 1BProduct Overview System Overview Figure 1. Top Down View – Passive System Shown 2.3 System Dimensions Table 3. System Dimensions Revision 2.0 Height 43.2 mm 1.70 in Width without rails 430.0 mm 16.93 in Width with rails 470.0 mm 18.50 in Depth without CMA 665.5 mm 26.2 in Depth with CMA 812.8 mm 32.00 in Maximum Weight 17.2 kg 38.
1BProduct Overview 2.
Intel® Server System SR1625UR TPS 2.5 1BProduct Overview Hard Drive and Peripheral Bays The system is designed to support 2.5 inch hot-swap SAS or SATA hard disk drives. When configured with the Mini Control Panel option, the system can support up to eight 2.5 inch drives. When configured with the Standard Control Panel or Intel® Local Control Panel, the system can support up to six 2.5 inch drives.
1BProduct Overview 2.6 Intel® Server System SR1625UR TPS System Board Overview ® Figure 4. Intel Server Board S5520UR The following figure shows the board layout of the server board. Each connector and major component is identified by a number or letter, and a description is given below the figure. 10 Intel order number E47487-012 Revision 2.
Intel® Server System SR1625UR TPS 1BProduct Overview ® Figure 5. Intel Server Board S5520UR Components Revision 2.
1BProduct Overview Intel® Server System SR1625UR TPS Table 5.
Intel® Server System SR1625UR TPS 1BProduct Overview AF002833 A POST Code Diagnostic LEDs F CPU 1 DIMM Fault LEDs B System Identification LED G CPU 2 Fan Fault LED C Status LED H Memory 2 Fan Fault LED D Memory 1 Fan Fault LED I CPU 2 DIMM Fault LEDs E CPU 1 Fan Fault LED J 5V Standby LED ® Figure 7. Intel Light-Guided Diagnostic LEDs - Server Board Revision 2.
1BProduct Overview 2.7 Intel® Server System SR1625UR TPS Front Bezel Support The optional front bezel is made of molded plastic and uses a snap-on design with a key lock. When installed, its design allows for maximum airflow. Figure 8. Optional Front Bezel Separate front bezels are available to support systems that use either a Mini Control Panel, Standard Control Panel or Intel® Local Control Panel with LCD support.
Intel® Server System SR1625UR TPS 1BProduct Overview When the Intel® Local Control Panel is used, the control panel module can be adjusted to extend further out from the chassis face to allow the LCD panel to protrude from the front bezel. ® Figure 11. Front Bezel Supporting Intel Local Control Panel 2.8 Rack and Cabinet Mounting Options The system was designed to support 19 inches wide by up to 30 inches deep server cabinets.
2BPower Subsystem 3. Intel® Server System SR1625UR TPS Power Subsystem The power subsystem of the system consists of an integrated Power Distribution Module (PDM), a Power Module Enclosure, and support for up to two 650-W power supply modules. The power subsystem can be configured to support a single module in a 1+0 non-redundant configuration, or dual modules in a 1+1 redundant power configuration. In a 1+1 configuration, a single failed power module can be hot-swapped with the system running.
Intel® Server System SR1625UR TPS +12VRS- +12VRS+ PDB_Fault 12LS SMB ALERT SDA SCL PS_ON PS_Kill PW_OK Present +12 A1 +12 V Vsense- Bottom 5VSdBy 5VSdBy DC Output Connection (Card Edge) 5VSdBy V Top A0 5VSdBy Ground Ground PDB_Alert 3.1.1 2BPower Subsystem Figure 13. DC Output Connection (Card Edge) 3.2 Single Power Supply Module Population In single power module configurations, the server management firmware requires that power supply module #1 be populated.
2BPower Subsystem Intel® Server System SR1625UR TPS Configuring a single power supply module in the #2 module slot causes the server management firmware and BIOS to generate a system error during POST and the error is reported to the System Event Log. It also causes the system status LED on the control panel to blink green, denoting a degraded system configuration. 3.3 Handle and Retention Mechanism The power supply includes a handle to grip the power supply for removal and insertion.
Intel® Server System SR1625UR TPS 3.5.1 2BPower Subsystem P1 – Server Board Power Connector Connector housing: 24-pin Molex* Mini-Fit Jr. 39-01-2245 or Intel approved equivalent Contact: Molex Mini-Fit, HCS, Female, Crimp 44476-1111 or Intel approved equivalent Table 7. P1 Main Power Connector Pin 1 Signal +3.3 VDC 18 AWG Color Orange Pin 13 Signal +3.3 VDC 18 AWG Color Orange 2 +3.
2BPower Subsystem 3.5.3 Intel® Server System SR1625UR TPS P3 – Power Signal Connector Connector housing: 5-pin Molex* 50-57-9705 or Intel approved equivalent Contact: Molex 16-02-0087 or Intel approved equivalent Table 9. P3 Power Signal Connector 3.5.4 Pin Signal 1 I C Clock 24 AWG Color 2 White/Green Stripe 2 2 I C Data White/Yellow Stripe 3 SMBAlert# White 4 ReturnS Black 5 3.
Intel® Server System SR1625UR TPS 3.6 2BPower Subsystem AC Input Requirements The power supply module incorporates universal power input with active power factor correction, which reduces line harmonics in accordance with the EN61000-3-2 and JEIDA MITI standards. 3.6.1 AC Inlet Connector The AC input connector is an IEC 320 C-14 power inlet. This inlet is rated for 15 A/250 VAC. 3.6.
2BPower Subsystem 3.6.4 Intel® Server System SR1625UR TPS AC Input Voltage Specification The power supply must operate within all specified limits over the input voltage range shown in the following table: Table 14. AC Input Rating Parameter Minimum Rated Maximum Startup VAC Power-off VAC Maximum Input AC Current Line Voltage (110) 90 Vrms 100-127 Vrms 140 Vrms 85 VAC ±4 VAC 75 VAC ± 5 VAC 8.5 Arms Line Voltage (220) 180 Vrms 200-240 Vrms 264 Vrms - - 4.
Intel® Server System SR1625UR TPS 2BPower Subsystem The power supply must meet the AC inrush current requirements for any rated AC voltage, during turn-on at any phase of AC voltage, during a single cycle AC dropout condition as well as upon recovery after AC dropout of any duration, and over the specified temperature range Top, (includes hot and cold inrush). It is acceptable that AC line inrush current may reach up to 60 A peak for up to 1 msec. 3.6.
2BPower Subsystem 3.7.2 Intel® Server System SR1625UR TPS Voltage Regulation The power supply output voltages must stay within the voltage limits defined in the following table when operating at steady state and dynamic loading conditions. These limits include the peak-peak ripple/noise. All outputs are measured with reference to the return remote sense signal (ReturnS). The +12 V and +5 VSB voltages are measured at the PDB output harness connector. Table 16.
Intel® Server System SR1625UR TPS 3.8.2 2BPower Subsystem Over-voltage Protection (OVP) Each DC/DC converter output on the PDB has individual OVP protection circuits built in and they are locally sensed. The PS and PDB shut down and latch off after an over-voltage condition occurs. This latch is cleared by toggling the PSON# signal or by an AC power interruption. The over-voltage limits are measured at the PDB harness connectors and are listed in the following table.
3BCooling Subsystem 4. Intel® Server System SR1625UR TPS Cooling Subsystem Several components and configuration requirements make up the cooling subsystem. These include the system fan module, the power supply fans, power supply air duct, CPU air duct, DIMM blanks, and drive bay population. All are necessary to provide and regulate the airflow and air pressure needed to maintain the system’s thermals when operating at or below maximum specified thermal limits.
Intel® Server System SR1625UR TPS 3BCooling Subsystem The individual system fans are not hot-swappable and require the system to be turned off before being replaced. The chassis is classified as a “Service Access Only” device and caution should be exercised when replacing a system fan, as they do not have finger guards. However, provisions are built into the fan bracket to prevent accidental contact with the fan rotors. Each fan within the module is capable of supporting multiple speeds.
3BCooling Subsystem Intel® Server System SR1625UR TPS Figure 17. Fan Header Assignments on Midplane Table 21. Fan Header Assignment Fan ID Fan #1 – CPU2/System memory cooling Fan #2 – CPU2/System memory cooling Fan #3 – CPU1/System Memory cooling Fan #4 – CPU1/System Memory cooling Fan #5 - Full-height Riser Zone cooling 4.
Intel® Server System SR1625UR TPS 3BCooling Subsystem Figure 18. Power Supply Air Duct 4.2.2 PCI Riser Zone The PCI riser zone is the area between the power supply assembly and the PCI riser card of the riser assembly. The airflow through this area is generated by Fan 5 of the fan module. Air is drawn from the drive bay area through the fan and pushed out of the system through ventilation holes at the back of the chassis. 4.2.
3BCooling Subsystem Intel® Server System SR1625UR TPS Figure 19. Air Duct 4.3 Drive Bay Population To maintain the proper air pressure within the system, all hard drive bays must be populated with either a hard drive, or drive blank. Figure 20. 2.5 inch Drive Blank 4.4 Sata HDD Support Due to the rotational velocity and vibration impacts that fans have on hard drives, fan redundancy is only supported when using SAS hard drives.
Intel® Server System SR1625UR TPS 5. 4BSystem Board Interconnects System Board Interconnects System boards within the system include two types of midplanes, a bridge board, a hard drive backplane, a PCI riser board, and three types of control panels. This chapter describes the interconnect features of each and defines the pin-outs for each of their connectors. Functional details of each system board are described in later chapters. 5.
4BSystem Board Interconnects Intel® Server System SR1625UR TPS The system also supports an active SAS/SAS RAID midplane. This system board incorporates an LSI LSISAS1078 SAS controller onto the board. For information about SAS/SAS RAID support, see Chapter 6. The following figure shows the location for each connector found on this board.
Intel® Server System SR1625UR TPS Pin 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 Revision 2.
4BSystem Board Interconnects Pin 53 54 55 56 57 58 59 60 Intel® Server System SR1625UR TPS Signal Name LED_FAN4_FAULT FAN_PWM3 GND PCI_FAN_TACH10 FAN_TACH8 FAN_TACH6 FAN_TACH4_H7 FAN_TACH2_H7 Pin Signal Name 113 FAN_PWM_CPU1 114 GND 115 FAN_PWM_CPU2 116 PCI_FAN_TACH9 117 FAN_TACH7 118 FAN_TACH5 119 FAN_TACH3_H7 120 FAN_TACH1_H7 Table 23.
Intel® Server System SR1625UR TPS 4BSystem Board Interconnects Pin 5 6 7 8 9 10 Signal Description GND P12V P12V P12V P12V P5V_STBY Table 25.
4BSystem Board Interconnects Intel® Server System SR1625UR TPS Pin Signal Name A1 SGPIO_DATAOUT0 A2 SGPIO_DATAOUT1 A3 GND A4 GND A5 SATA_ADDIN2_RX_N A6 SATA_ADDIN2_RX_P A7 GND A8 GND A9 SATA_ADDIN2_TX_P A10 SATA_ADDIN2_TX_N A11 GND A12 SMB_PBI_3VSB_DAT A13 SMB_PBI_3VSB_CLK A14 USB0_ESB_OC_N A15 GND A16 GND A17 USB0_ESB_DP A18 USB0_ESB_DN A19 GND A20 LED_NIC1_ACT_N A21 LED_NIC1_LINK_N A22 FM_SIO_TEMP_SENSOR A23 LED_NIC2_LINK_N A24 LED_NIC2_ACT_N A25 GND A26 V_BLUE_CONN_FP A27 V_GREEN_CONN_FP A28 V_RED_CONN
Intel® Server System SR1625UR TPS 4BSystem Board Interconnects Pin 13 14 15 16 17 18 19 20 Signal Description SMB_CLK_P3V3 GND SMB_DAT_P3V3 BBU_PFAIL_N BBU_DDR_SEL BBU_BBE BBU_BBSTROBE BBU_BBSTATUS Table 28. Passive Midplane SATA/SAS Connector Pin-outs Pin 1 2 3 4 5 6 7 J5A2 - SAS_7 Signal Name GND SATA_ADDIN1_TX_P SATA_ADDIN1_TX_N GND SATA_ADDIN1_RX_N SATA_ADDIN1_RX_P GND Pin 1 2 3 4 5 6 7 J5A1- SAS_8 Signal Name GND SATA_ADDIN2_TX_P SATA_ADDIN2_TX_N GND SATA_ADDIN2_RX_N SATA_ADDIN2_RX_P GND 5.
4BSystem Board Interconnects Intel® Server System SR1625UR TPS Figure 23. Bridge Board 5.3 Hot-Swap SATA/SAS Backplane The hot-swap backplane provides support for both SAS and SATA hard drives. There are no hard drive cables that connect to the backplane. All hard drive control signals are routed from the midplane board, which plugs directly into the backplane. A Slimline Optical Device Connector B Mini Control Panel Connector C SAS/SATA hot-swap Connectors Figure 24.
Intel® Server System SR1625UR TPS 4BSystem Board Interconnects A USB Connector C Card Edge Connectors to Midplane B Power Connector D 10-pin Control Panel Connector Figure 25. Hot-Swap SAS/SATA Backplane (Back Side View) Table 29. 2x4 SAS/SATA Backplane Power Connector Pin-out Pin # 1 2 3 4 5 6 7 8 Signal Name Ground Ground P5V P5V P12V P12V P5V_STBY P3V3 Table 30.
4BSystem Board Interconnects Intel® Server System SR1625UR TPS Pin # Signal Name P1 P2 P3 P4 P5 P6 N/C P5V P5V N/C GND GND 2 Table 32. I C Connector Pin # 1 2 3 4 Signal Description SMB_VSC_12C_DAT0 GROUND SMB_VSC_12C_CLK0 Not Used Table 33.
Intel® Server System SR1625UR TPS 4BSystem Board Interconnects Table 34. PCI Express* x4 Slot Connector from Midplane Pin # A1 A2 A3 A4 A5 A6 A7 A8 A9 A10 A11 A12 A13 A14 A15 A16 A17 A18 A19 A20 A21 A22 A23 A24 A25 A26 A27 A28 A29 A30 A31 A32 Revision 2.
4BSystem Board Interconnects Intel® Server System SR1625UR TPS ® Table 35. Intel Local Control Panel (LCP) Connector Pin # 1 2 3 4 Signal Description SMB_IPMB_5VSB_DAT Ground SMB_IPMB_5VSB_CLK P5V_STBY_R Table 36.
Intel® Server System SR1625UR TPS 4BSystem Board Interconnects Table 38. SAS/SATA Hard Drive Connector Pin-outs Pin# SI S2 S3 S4 S5 S6 S7 S8 S9 S10 S11 S12 S13 S14 P1 P2 P3 P4 P5 P6 P7 P8 P9 P10 P11 P12 P13 P14 P15 PTH0 PTY1 Revision 2.
5BPeripheral Drive Support 6. Intel® Server System SR1625UR TPS Peripheral Drive Support The system provides a slimline drive bay that can be populated with an SATA optical drive (CDROM, DVD, DVD/CDR). Drives are mounted on a tool-less tray which allows for easy installation into and removal from the system. The slim-line devices are not hot- swappable. 6.1 Optical Drive Support The system provides a slimline drive bay that is designed to support a single slimline SATA optical drive.
Intel® Server System SR1625UR TPS 5BPeripheral Drive Support Pin # Signal Name KEY P1 P2 P3 P4 P5 P6 Revision 2.
6BHard Disk Drive Support 7. Intel® Server System SR1625UR TPS Hard Disk Drive Support The system can be configured to support several different hard drive and peripheral configurations. The peripheral/hard drive subsystem consists of a drive bay supporting a slimline optical drive, and hard drives; a midplane; and a hot-swap backplane. This chapter describes the details for each subsystem component. A Slimline SATA Optical Drive Bay B Mini Control Panel C 2.
Intel® Server System SR1625UR TPS A B C D 6BHard Disk Drive Support 2.5 inch hard drive Four screws to mount the hard drive Hard drive carrier Green touch point to extract the carrier Figure 28. Hard Drive Tray Assembly 7.2 Midplane Options The midplane is designed and used, along with that of the bridge board and hot-swap backplane, to improve cable routing within the system. The midplane is the key system board of the system.
6BHard Disk Drive Support A. Intel® Server System SR1625UR TPS Power Connector F. Fan 4 Connector B. Fan 6 Connector G. Fan 3 Connector C. Fan 5 Connector H. Fan 1 Connector D. SAS/SATA Connectors I. Fan 2 Connector E. Bridge Board Connector J. Backplane Connector Figure 29. Passive Midplane Board 7.2.2 Active Midplane with Intel® SAS /SAS RAID Support The active midplane is used to provide SAS/SAS RAID support. It has an integrated LSI LSLSAS1078 3 Gb/s RAID On-a-Chip (ROC) device.
Intel® Server System SR1625UR TPS 6BHard Disk Drive Support B. C. D. RAID Battery Backup Unit Connector Power Connector Mini-DIMM Connector Fan 6 Connector E. Fan 5 Connector K. F. Bridge Board Connector L. A. G. Fan 4 Connector H. I. J. Fan 3 Connector Fan 1 Connector Fan 2 Connector RAID Activation Key Connector Backplane Connector Figure 30. Active Midplane with SAS/SAS RAID Support Revision 2.
6BHard Disk Drive Support 7.2.2.1 Intel® Server System SR1625UR TPS Active Midplane Architectural Overview Figure 31. Active Midplane Architecture Diagram 7.2.2.2 x4 PCI Express* Card Edge Interfaces Two x4 PCI Express* card edges are used to connect the active midplane to the hot-swap backplane. The use of card edge connectors to the backplane eliminates all hard drive cabling. 7.2.2.3 LSI LSISAS1078 SAS Controller The LSI LSISAS1078 ROC supports transfer rates of up to 3 GB/s on each SAS port.
Intel® Server System SR1625UR TPS 7.2.2.4.2 6BHard Disk Drive Support Intel RAID Cache support To further enable support for hardware RAID, the active midplane provides a 244-pin miniDIMM connector (J8C1), supporting a single registered ECC non-parity DDR2-667 MHz MiniDIMM to provide Intel RAID cache. Supported mini-DIMM capacities range from 128 MB to 1 GB. Note: For a list of Intel validated mini-DIMMs, use the Server Configurator Tool available at http://serverconfigurator.intel.com/default.aspx. 7.
6BHard Disk Drive Support Intel® Server System SR1625UR TPS A Slimline Optical Device Connector B Mini Control Panel Connector C SAS/SATA hot-swap Connectors Figure 32. Hot-Swap SAS/SATA Backplane (Front Side View) A USB Connector C Card Edge Connectors to Midplane B Power Connector D 10-pin Control Panel Connector Figure 33.
Intel® Server System SR1625UR TPS 7.3.2 6BHard Disk Drive Support SAS/SATA Backplane Functional Architecture The following figure shows the functional blocks of the SAS/SATA backplane. Figure 34. SAS/SATA Backplane Functional Block Diagram 7.3.2.1 Enclosure Management Controller The backplane utilizes the features of the Vitesse* VSC410 to implement several enclosure management functions. The chip provides in-band SAF-TE and SES management and utilizes the following four I2C interfaces: 1. 2. 3. 4.
6BHard Disk Drive Support Intel® Server System SR1625UR TPS The activity LED functionality is controlled directly by the hard drives. This causes the LED to function differently between SAS and SATA drives. The expected operation is outlined in the following table. Table 41.
Intel® Server System SR1625UR TPS 8. 7BMini Control Panel Functionality Mini Control Panel Functionality For system configurations that require eight 2.5 inch hard drives, a mini control panel is used in place of the standard control panel. The mini control panel is modular in design and supports several push buttons and status LEDs, along with one USB port within a very compact design.
7BMini Control Panel Functionality Intel® Server System SR1625UR TPS Table 42. Mini Contol Panel Button Functions Reference A Feature ID Button B NMI Button C Power/Sleep Button 8.2 Function Toggles the front panel ID LED and the server board ID LED on/off. The server board ID LED is visible through the rear of the system and allows for server identification and location when working behind a rack of servers.
Intel® Server System SR1625UR TPS 8.2.1 7BMini Control Panel Functionality Power/Sleep LED Table 44. SSI Power LED Operation State Power-off Power-on S5 Power Mode Non-ACPI Non-ACPI ACPI Off On Off LED S4 ACPI Off S3-S1 ACPI Slow blink S0 ACPI Steady on Description System power is off, and the BIOS has not initialized the chipset. System power is on, but the BIOS has not yet initialized the chipset. Mechanical is off, and the operating system has not saved any context to the hard disk.
7BMini Control Panel Functionality Color State Intel® Server System SR1625UR TPS Criticality 8.2.3 Description Processor 1 missing. Temperature (e.g. CPU ThermTrip, memory TempHi, critical threshold crossed). No power good – power fault. Processor configuration error (e.g. processor stepping mismatch). System Identification LED The blue system identification LED is used to help identify a system for servicing.
Intel® Server System SR1625UR TPS 7BMini Control Panel Functionality Figure 38. Mini Control Panel PCB Table 47. 20-pin Mini Control Panel Interconnect Pin # 1 3 5 7 9 11 13 15 17 19 Revision 2.
8BStandard Control Panel Functionality 9. Intel® Server System SR1625UR TPS Standard Control Panel Functionality The standard control panel supports several push buttons and status LEDs, along with USB and video ports to centralize system control, monitoring, and accessibility within a compact design. Using the standard control panel allows up to six 2.5 inch hard drives to be installed in the system. The standard control panel assembly comes pre-assembled and is modular in design.
Intel® Server System SR1625UR TPS 8BStandard Control Panel Functionality Table 48. Standard Contol Button and Intrusion Switch Functions Reference A B C Reset Button NMI Button D 9.2 Feature Power/Sleep Button ID Button Function Toggles the system power on/off. This button also functions as a Sleep button if enabled by an ACPI-compliant operating system. Toggles the front panel ID LED and the server board ID LED on/off.
8BStandard Control Panel Functionality Intel® Server System SR1625UR TPS Table 49. Standard Control Panel LED Functions Reference LED Color Green Green Green A NIC1/NIC2 Activity B Power/Sleep (on standby power) C Disk Activity D System Status (on standby power) E System Identification Off Green Off Green Amber Off Blue Off State On Blink On 1,4 Blink Off Random blink 3 Off On Description NIC Link. NIC Activity. Legacy power on/ACPI S0 state. Sleep/ACPI S1 state.
Intel® Server System SR1625UR TPS 9.2.2 8BStandard Control Panel Functionality System Status LED Table 51. Control Panel LED Operation Color Off Green Green State N/A Solid on Blink Criticality Not ready Ok Degraded Description AC power off. System booted and ready. System degraded Unable to use all of the installed memory (more than one DIMM installed). Correctable errors over a threshold of ten and migrating to a spare DIMM (memory sparing).
8BStandard Control Panel Functionality 9.2.4 Intel® Server System SR1625UR TPS System Identification LED The blue system identification LED is used to help identify a system for servicing. This is especially useful when the system is installed in a high density rack or cabinet that is populated with several similar systems. The system ID LED blinks when the System ID button on the control panel is pressed or it can be illuminated remotely through the server management software. 9.
Intel® Server System SR1625UR TPS 8BStandard Control Panel Functionality Figure 42. Standard Control Panel PCB Table 54.
9BIntel® Local Control Panel Functionality Intel® Server System SR1625UR TPS 10. Intel® Local Control Panel Functionality The Intel® Local Control Panel (LCP) utilizes a combination of control buttons, LEDs, and LCD display to provide system accessibility, monitoring, and control functions. The pre-assembled module slides into a slot on the front of the chassis where it is cabled to the backplane. The LCP module is designed so that it can be adjusted for use with or without an outer front bezel.
Intel® Server System SR1625UR TPS 9BIntel® Local Control Panel Functionality 10.1 LED Functionality The following table identifies each LED and describes their functionality: Table 56.
9BIntel® Local Control Panel Functionality 10.1.2 Intel® Server System SR1625UR TPS System Status LED Table 58. Control Panel LED Operation Color State Off Green Green N/A Solid on Blink Not ready Ok Degraded AC power off System booted and ready System degraded Unable to use all of the installed memory (more than one DIMM installed). Correctable errors over a threshold of ten and migrating to a spare DIMM (memory sparing).
Intel® Server System SR1625UR TPS 9BIntel® Local Control Panel Functionality By pressing the System ID button on the system control panel, the ID LED displays a solid blue color until the button is pressed again. By issuing the appropriate hex IPMI “Chassis Identify” value, the ID LED either blinks blue for 15 seconds and turns off or blinks indefinitely until the appropriate hex IPMI Chassis Identify value is issued to turn it off. 10.
9BIntel® Local Control Panel Functionality Intel® Server System SR1625UR TPS Table 60. 10-pin Control Panel USB Connector Pin # 1 2 3 4 5 6 7 8 9 10 Signal Description P5V_USB_P1 USB_P1N USB_P1P GND GND P5V_USB_P2 USB_P2N USB_P2P GND GND Table 61. Internal NMI/Temp Sensor Header 70 Pin # Description 1 2 3 4 DGND FP_NMI_BTN_L +3_3VSB 1_WIRE_BUS Intel order number E47487-012 Revision 2.
Intel® Server System SR1625UR TPS 10BPCI Riser Cards and Assembly 11. PCI Riser Cards and Assembly The Intel® Server System SR1625UR provides one x16 PCI Express* Gen 2 PCI riser slot capable of supporting a full-length full-height PCI Express* add-in card. When re-inserting the riser assembly into the system, tabs on the back of the assembly should be aligned with slots on the back edge of the system. The tabs fit into the slots securing the riser assembly to the system when the top cover is in place.
Environmental Specifications Intel® Server System SR1625UR TPS 12. Environmental Specifications 12.1 System Level Environmental Limits The following table defines the system level operating and non-operating environmental limits. Table 62.
Intel® Server System SR1625UR TPS Environmental Specifications 12.3 Replacing the Backup Battery The lithium battery on the server board powers the real time clock (RTC) for up to 10 years in the absence of power. When the battery starts to weaken, it loses voltage, and the server settings stored in CMOS RAM in the RTC (e.g., the date and time) may be wrong. Contact your customer service representative or dealer for a list of approved devices.
12BRegulatory and Certification Information Intel® Server System SR1625UR TPS 13. Regulatory and Certification Information WARNING To ensure regulatory compliance, you must adhere to the assembly instructions in this document to ensure and maintain compliance with existing product certifications and approvals. Use only the described, regulated components specified in this document.
Intel® Server System SR1625UR TPS 13.1.
12BRegulatory and Certification Information Intel® Server System SR1625UR TPS BSMI Certification (Taiwan) GOST R Certification/Certification (Russia) Belarus Certification/Certification (Belarus) KCC Certification (Korea) IRAM Certification (Argentina) Ecology Declaration (International) China RoHS Environmental Friendly Use Period Packaging & Product Recycling Marks 13.
Intel® Server System SR1625UR TPS Regulatory Compliance 12BRegulatory and Certification Information Country GOST R Marking Russia KCC Mark (Korean Communications Comission) Korea Belarus Safety Compliance Mark Belarus Waste of Electronic and Electrical Equipment Recycling Mark Europe China Restriction of Hazardous Substance Environmental Friendly Use Period Mark China China Recycling Mark China Recycling Marks International Battery Perchlorate Warning Information California Safety Multipl
12BRegulatory and Certification Information Regulatory Compliance Country Intel® Server System SR1625UR TPS Marking 本设备包括多条电源系统电缆。为避免遭受电击,在进行维 修之前应断开两(2)条电源系统电缆。 Traditional Chinese: 注意: 本設備包括多條電源系統電纜。為避免遭受電擊,在進行維 修之前應斷開兩(2)條電源系統電纜。 German: Dieses Geräte hat mehr als ein Stromkabel. Um eine Gefahr des elektrischen Schlages zu verringern trennen sie beide (2) Stromkabeln bevor Instandhaltung.
Intel® Server System SR1625UR TPS 12BRegulatory and Certification Information Over-current protection: The server is designed for an AC line voltage source with up to 20 amperes of over-current protection per cord feed. If the power system for the equipment rack is installed on a branch circuit with more than 20 amperes of protection, you must provide supplemental protection for the server.
12BRegulatory and Certification Information Intel® Server System SR1625UR TPS certification by an agency acceptable in your region and for U.S. must be Listed and rated 125% of overall current rating of the server. Connector, server end: The connectors that plug into the AC receptacle on the server must be an approved IEC (International Electrotechnical Commission) 320, sheet C13, type female connector. Cord length and flexibility: Cords must be less than 4.5 meters (14.76 feet) long. 13.
Intel® Server System SR1625UR TPS 13.5.2 12BRegulatory and Certification Information ICES-003 (Canada) Cet appareil numérique respecte les limites bruits radioélectriques applicables aux appareils numériques de Classe Aprescrites dans la norme sur le matériel brouilleur: “Appareils Numériques”, NMB-003 édictée par le Ministre Canadian des Communications.
12BRegulatory and Certification Information 13.5.6 Intel® Server System SR1625UR TPS KCC (Korea) Following is the KCC certification information for Korea: English translation of the notice above: 1. 2. 3. 4. 5. Type of Equipment (Model Name): On Certification and Product Certification No.: On KCC certificate.
Intel® Server System SR1625UR TPS Appendix A: Integration and Usage Tips Appendix A: Integration and Usage Tips This section provides a list of useful information that is unique to the Intel® Server System SR1625UR and should be kept in mind while integrating and configuring your Intel® Server Board S5520UR. Only low-profile (1.2 in or 30.48 mm) DIMMs can be used in the server system. Processor fans are not supported and are not needed in the server system.
Appendix B: POST Code Diagnostic LED Decoder Intel® Server System SR1625UR TPS Appendix B: POST Code Diagnostic LED Decoder During the system boot process, the BIOS executes a number of platform configuration processes, each of which is assigned a specific hex POST code number. As each configuration routine is started, the BIOS displays the POST code to the POST Code Diagnostic LEDs on the back edge of the server board.
Intel® Server System SR1625UR TPS Appendix B: POST Code Diagnostic LED Decoder Table 65.
Appendix B: POST Code Diagnostic LED Decoder Intel® Server System SR1625UR TPS Diagnostic LED Decoder O = On, X=Off Upper Nibble Lower Nibble Checkpoint MSB 8h #7 X X X X X X 4h #6 O O O O O O 2h #5 X X X X X X 1h #4 O O O O O O 8h #3 X X X X X X 4h #2 X X O O O O 2h #1 O O X X O O LSB 1h #0 X O X O X O Description LED 0x52h 0x53h 0x54h 0x55h 0x56h 0x57h USB 0x58h X O X O O X X X Resetting USB bus 0x59h X O X O O X X O Reserved for USB devices ATA/ATAPI/SATA 0x5Ah X O X O
Intel® Server System SR1625UR TPS Diagnostic LED Decoder O = On, X=Off Upper Nibble Lower Nibble Checkpoint LED Appendix B: POST Code Diagnostic LED Decoder MSB 8h #7 4h #6 2h #5 1h #4 8h #3 4h #2 2h #1 Description LSB 1h #0 etc.
Appendix B: POST Code Diagnostic LED Decoder Diagnostic LED Decoder O = On, X=Off Upper Nibble Lower Nibble Checkpoint LED Intel® Server System SR1625UR TPS MSB 8h #7 4h #6 2h #5 1h #4 8h #3 4h #2 2h #1 Description LSB 1h #0 X O X OS has requested the system to reset (ResetSystem ( ) has been called) Pre-EFI Initialization Module (PEIM)/Recovery 0x30h X X O O X X X X Crisis recovery has been initiated because of a user request 0xFAh O O O O O 0x31h X X O O X X X O Crisis
Intel® Server System SR1625UR TPS Appendix C: POST Code Errors Appendix C: POST Code Errors Whenever possible, the BIOS outputs the current boot progress codes on the video screen. Progress codes are 32-bit quantities plus optional data. The 32-bit numbers include class, subclass, and operation information. The class and subclass fields point to the type of hardware that is being initialized. The operation field represents the specific initialization activity.
Appendix C: POST Code Errors Error Code 8140 8141 8160 8161 8170 8171 8180 8181 8190 8198 8300 84F2 84F3 84F4 84FF 8500 8520 8521 8522 8523 8524 8525 8526 8527 8528 8529 852A 852B 852C 852D 852E 852F 8540 8541 8542 8543 8544 8545 8546 8547 8548 8549 854A 854B 854C 854D 854E 854F 8560 8561 8562 8563 8564 90 Intel® Server System SR1625UR TPS Error Message Processor 01 Failed FRB-3 Timer. Processor 02 Failed FRB-3 Timer. Processor 01 unable to apply BIOS update. Processor 02 unable to apply BIOS update.
Intel® Server System SR1625UR TPS Error Code 8565 8566 8567 8568 8569 856A 856B 856C 856D 856E 856F 8580 8581 8582 8583 8584 8585 8586 8587 8588 8589 858A 858B 858C 858D 858E 858F 85A0 85A1 85A2 85A3 85A4 85A5 85A6 85A7 85A8 85A9 85AA 85AB 85AC 85AD 85AE 85AF 8601 8602 8603 Revision 2.0 Appendix C: POST Code Errors Error Message DIMM_B2 Component encountered a Serial Presence Detection (SPD) fail error. DIMM_B3 Component encountered a Serial Presence Detection (SPD) fail error.
Appendix C: POST Code Errors Error Code 8604 9000 9223 9226 9243 9246 9266 9268 9269 9286 9287 9288 92A3 92A9 92C6 92C7 92C8 94C6 94C9 9506 95A6 95A7 95A8 9609 9641 9667 9687 96A7 96AB 96E7 0xA022 0xA027 0xA028 0xA421 0xA500 0xA501 0xA5A0 0xA5A1 0xA5A4 0xA6A0 Intel® Server System SR1625UR TPS Error Message Chipset Reclaim of non critical variables complete. Unspecified processor component has encountered a non specific error. Keyboard component was not detected.
Intel® Server System SR1625UR TPS Beeps 3 Error Message Memory error Appendix C: POST Code Errors POST Progress Code 0xE8, 0xEB, 0xED, 0xEE Description System halted because a fatal error related to the memory was detected. The Integrated BMC may generate beep codes upon detection of failure conditions. Beep codes are sounded each time the problem is discovered, such as on each power-up attempt, but are not sounded continuously.
Appendix C: POST Code Errors Intel® Server System SR1625UR TPS Table 68. Integrated BMC Beep Codes 94 Code 1-5-2-1 Reason for Beep CPU: Empty slot/population error – Processor slot 1 is not populated. Associated Sensors CPU Population Error Supported? Yes 1-5-4-2 Power fault: DC power unexpectedly lost (power good dropout). Power Unit – power unit failure offset Yes 1-5-4-4 Power control fault. Power Unit – soft power control failure offset Yes Intel order number E47487-012 Revision 2.
Intel® Server System SR1625UR TPS Glossary Glossary Word/Acronym ACA Australian Communication Authority ANSI American National Standards Institute BMC Baseboard Management Controller BIOS Basic Input/Output System CMOS Complementary Metal-oxide-semiconductor D2D DC-to-DC EMP Emergency Management Port FP Front Panel FRB Fault Resilient Boot FRU Field Replaceable Unit 2 Definition IC Inter-integrated Circuit bus LCD Liquid Crystal Display LPC Low-pin Count LSB Least Significant
Reference Documents Intel® Server System SR1625UR TPS Reference Documents See the following documents for additional information: 96 Intel® Server Board S5520UR Technical Product Specification ® Intel Server System SR1625UR AC Power Supply Module Specification Intel® Server Board S5520UR/Intel® Server System SR1625UR Spares/Parts List and Configuration Guide Intel® Server System SR1625UR Service Guide Intel® S5500/S5520 Server Board Family BIOS External Product Specification Intel® Server Sy