Quick Start Guide Page 2

Side 2
16
Install Standard Control Panel or Intel® Local Control Panel (optional)
Slide the control panel fully into the
server system until it clicks into place.
C
Feed the control panel cables
into the chassis opening.
B
Connect the USB and data cables to the
replacement control panel as shown.
A
Connect the two cables to the USB
and control panel connectors on the
back side of the backplane as shown.
D
Install the mini control panel
filler panel.
E
Remove the filler on the right as shown.
B
Press the latch at the back of the mini control
panel and push the control panel forward to
release it from the chassis.
A
Slide the mini control panel out through the
front of the server system.
C
Remove the Mini Control Panel Install the Standard or Intel® Local Control Panel
Latch
Mini Control
Panel
Local
Control Panel
A
C
B
Filler Panel
Local
Control Panel
Filler Panel
B
A
Backplane
C
D
E
17
Install Processor
Air Duct
Use care
to avoid
pinching
system
cables.
Processor
Air Duct
18
Install Add-in Card
(optional)
A
Remove filler panel from the add-in card slot.
B
Insert add-in card until it seats in riser connector.
C
Secure the add-in card with screw as shown.
D
Remove the screw as shown.
CAUTION:
Observe normal ESD precautions
when installing the add-in card.
Riser Connector
REMOVE Filler Panel
D
B
A
C
19
Install Add-in Card
Riser Assembly
Riser Card
Edge Connector
Press down uniformly until the
two hooks on the rear of the
PCI riser assembly
engage the chassis
back panel slots.
The riser card will
seat into the
matching riser
socket on the
server board.
B
PCI Riser
Socket
Chassis
Slots (2)
Hooks (2)
Processor
Air Duct
Air Duct
Slot
Position riser card edge connector over
the server board riser socket and align
the two hooks in the riser with the
slots at the back of the chassis.
A
Note that the riser assembly card edge installs in
the slot in the processor air duct.
12
Install Passive System (Product Code: SR1625UR) Components
...for an Active System, go to Step 11
Connect SATA cables from passive midplane
board to server board as shown.
Route cables under the retention
tab and alongside the power
supply as shown to allow
clearance for a full-
height PCI add-in
card.
A
B
Passive
Midplane
Power Distribution
Board Cover
A
B
0
3
2
1
4
5
Power Supply
Cable
Retention
Tab
CAUTION: It is critical that
you connect the SATA data
cables correctly from the
SATA midplane to your
server board or RAID
Controller card. Failure to
do so may result in data loss.
4
5
6
7
1
2
3
Passive Midplane
SATA Connectors
A
0
Server
Board
14
Install Optical Device
Insert the optical drive into
chassis opening and push all
the way until it stops.
B
Install the plastic guide
onto the back of the drive
and attach with two
screws as shown.
A
A
IMPORTANT NOTE: If you do not install a device at this location,
install the optical device bay filler panel shown below.
This is required to maintain proper system cooling.
B
20
Install
Rack
Handles
21
Install Top Cover
Note:
Security screw
re-installation is optional.
A
Place cover as shown, slide forward
to engage recessed edge at
front of cover. Make sure
latch is locked.
A
Recessed
Edge
11
Install Active System (Product Code: SR1625URSAS) Components ... for a Passive System, go to Step 12
Remove Power Distribution
Board Cover (optional)
This step is only necessary if you are
installing the optional RAID Battery
Backup Unit (BBU).
Power
Distribution
Board Cover
Check RAID BBU Battery Connection Install RAID Battery Backup Unit (optional) Install RAID DIMM and RAID Activation Key (optional) Install Power Distribution Board (PDB) Cover
The RAID BBU has an internal battery power
cable. Open the BBU case lid as shown.
A
If the battery power
cable is not
connected, connect
the cable now.
Close and latch
the BBU
case lid.
B
A
B
The RAID BBU has two hooks
on the underside. Align
these hooks with the
matching chassis
tabs, then slide
toward the power
supply to lock into place.
A
Connect the power cable
between the BBU and
the midplane
board as
shown.
B
Midplane RAID
BBU Connector
Chassis
Tab(2)
Power
Supply
Battery
Backup
Unit
A
B
Chassis
Standoff
PDB
Power
Distribution
Board
Power
Distribution
Board Cover
A
B
Insert the Intel
®
RAID Activation Key into the midplane board
socket as shown. Make sure the key snaps into the socket.
A
Open RAID mini DIMM socket levers and insert connector
edge of mini DIMM into socket until
levers close and snap into place.
B
Backplane Board not shown for clarity
Intel
®
RAID
Activation
Key Socket
RAID Mini DIMM
Socket
RAID Mini DIMM
RAID
Key
Open Levers
B
A
Midplane
Board
A
B
Install power distribution board cover by aligning with the power distribution board
and the matching thumbscrew hole.
Note that the thumbscrew attaches to a chassis
standoff underneath the PDB. If the PDB is not
installed correctly, the thumbscrew will not align
with the standoff.
Power
Distribution
Board Cover
Note: Standard and Intel
®
Local
Control Panel install the same.
22
Install Bezel (optional)
Mini Control Panel Bezel
Select the bezel
that matches your
control panel and
install as shown.
Intel® Local Control Panel Bezel
Standard Control Panel Bezel
Front Panel Controls and Indicators
Intel® Local Control Panel Standard Control Panel
A NIC2 Activity LED
B. NIC1 Activity LED
C. Power/Sleep Button
D. Power/Sleep LED
E. Hard Drive
Activity LED
F. Status LED
G. System ID LED
H. System ID Button
I. Reset Button
J. USB 1.1 Port
K. NMI (recessed)
Button
L. Video
A USB 1.1 Port
B. LCD Display
C. Menu Control Button - Up
D. Menu Control Button - Down
E. Menu Control Button - Left
F. Menu Control Button - Enter
G. ID LED
H. Power/Sleep LED
I. Power/Sleep Button
J. System Status LED
K. NIC 2 Activity LED
L. NIC 1 Activity LED
M. HDD Activity LED
N. Reset Button
O. USB 1.1 Port
BA DC
G EF
Mini Control Panel
A USB 1.1 Port
B. System ID LED
C. System Status LED
D. Power/Sleep LED
E. Power/Sleep Button
F. NMI Button
G. System ID Button
O M L K J HIN G
C
D
E
F
BA
J IL K
BA F G HEDC
24
Software
BIOS, Drivers, and Operating
System Installation
C. Install your Operating System:
Use the instructions provided with the RAID
controller and with the operating system.
D. Install Operating System Drivers:
With the operating system running, insert
the Intel
®
Server Deployment Toolkit CD. If using a Microsoft Windows*
operating system, the Express Installer will autorun and allow you to select the
appropriate drivers to install. On other operating systems, browse the CD folders
to locate and install the driver files.
E. Install Intel
®
System Management Software (optional):
Download the latest version of the Intel
®
System Management Software from
http://www.intel.com/go/servermanagement and use the instructions provided at
that link to install the software.
A. Update the System Software:
1. Boot from the Intel
®
Server Deployment Toolkit CD.
2. Use the Wizard to access the latest versions on the Internet and update the
BIOS, firmware, FRUSDRs, and Intel
®
RMM3.
Note: You can also use downloaded files on a USB key.
B. Configure your RAID Controller:
If using a RAID card, use the instructions
provided with the RAID controller. If using on-board RAID, you must activate RAID
in the BIOS setup. See the Intel
®
Server Board S5520UR Technical Product
Specification for more information.
Note: Rack handles are required to install the bezel.
For detailed instructions, see the Service Guide.
Install processor
air duct as shown
making sure the front
edge of the duct aligns
correctly with the
notches on the
fan module.
USB
Cable
Data
Cable
Note: To install hard drives in
drive locations 6 and 7, you
must remove the filler
panel.
13
Install Hard Drives/Carriers
Remove the drive
carrier by pressing in
on the green latch,
pulling out on the
black lever and sliding
the drive carrier out.
Repeat these steps for each installed hard drive
Note: Carrier lever must be held in the
FULLY OPEN position to install into
the chassis. Slide carrier into chassis
until it clicks, then close the lever.
A
Remove the plastic air baffle and
save for future use.
B
Install the hard disk drive
as shown.
C
Install hard disk drive assembly
into chassis
opening.
D
CAUTION: If you install less than eight
drives or devices, empty drive bays must
be occupied by carriers with baffles or
with a filler panel provided for drive
locations 6 and 7 to maintain proper
system cooling.
Drive 0 Primary
Hard Drive Numbering Diagram
31
2
7
64
5
0
Attach with
four screws.
C
Remove only when
installing hard drive device.
Keep for future use
B
Press in on the green
latch to open lever.
A
D
Note: To install hard drives
in drive locations 6 and 7,
remove the filler panel.
AXXHERAIL2
Cable Management Arm
Tool-less Rail Kit
AXXBASRAIL13
Basic Slide Rail Kit
ASR1550BEZ
Bezel for Standard Control Panel
Optional Accessories and Order Codes
AXXBRACKETS
AXXRACKARM2
Fixed Rack Brackets
ASR1550LCDBEZ
Bezel for Intel
®
Mini Control Panel
Bezel for Intel
®
Local Control Panel
AXXRAKSAS2
RAID Activation Key
AXXMINIDIMM512
RAID Mini DIMM
ASR1550MINBEZ
AXXSATADVDROM
Slimline DVD-ROM/CD-ROM Drive
A complete list of accessories and spares can be found at: http://support.intel.com/support/motherboards/server/s5520ur/
Intel
®
Remote Management Module 3
AXXRMM3
ASR1625PS
650-W Power Supply
ASR1625LCP
Intel
®
Local Control Panel Module
ASR1625FP
Standard Control Panel Module
Inifiniband* I/O Expansion Module
SAS I/O Expansion Module
Dual Gigabit I/O Expansion Module
AXXGBIOMOD
AXXSASIOMOD
Quad-Port Gigabit I/O Expansion Module
10 Gigabit I/O Expansion Module
AXX10GBIOMOD
AXXIBIOMOD
AXX4GBIOMOD2
15
Install Second Power Supply
(optional)
Use the 'finger hole' to remove the
filler panel.
To remove a power supply
module, push the green latch
in the direction shown while
pulling it out of the system
by the handle.
Insert the power supply module into the
power supply cage and push hard until it
clicks into place.
A
B
Handle
PS Latch
23
Finishing Up
Before installing your operating system, you must finish
your system installation, make I/O connections, and
plug in AC power.
AC Power
CAUTION: This unit must
be operated with the TOP
COVER installed to ensure
proper cooling.
Video
2. Install the server into the rack using the instructions
provided with the rack mounting kit.
1. Replace the system cover.
I/O Exp. Module
USB
Intel
®
RMM3 Module
Serial
Port A
Network
NIC1-2
3.
Connect your USB keyboard/mouse, video and other I/O
cables/devices as shown. Then connect the AC power cord.
Intel® Server Board S5520UR
Component Layout
See your Intel
®
Server System SR1625UR Service Guide for expanded component
and connection information.
Diag.
LEDs
USB
8, 9
USB
2, 5
Video
ID LED
Serial A
CPU 1
I/O Exp.
Module Conn. 1
I/O Exp.
Module Conn. 2
SGPIO
SATA Key
LCP/AUX IPMB
BMC Force
Update
Front USB
SSD
USB
Power
Supply
Signal
Conn.
Serial B
SATA 5
SATA 0
SATA 1
SATA 2
SATA 3
SATA 4
CPU 1 Fan
Mem 1 Fan
Status
LED
CPU 2
Fan
Mem 2
Fan
CPU
Power
Front
Panel
CPU 2
Bridge Board Conn.
Sys 1
Fan
Sys 2
Fan
NIC1
NIC2
DIMM A2
DIMM C1
DIMM A1
DIMM B2
DIMM B1
DIMM C2
Main Power
Fan Board
DIMM Status LEDs
Battery
DIMM F1
DIMM D2
DIMM F2
DIMM E1
DIMM E2
DIMM D1
PCIe* Riser
RMM3 Conn.
DIMM
Status
LEDs
BIOS
Recover
Password
Clear
BIOS
Default
Serial Port
Config.
Document/Tool
Available Documents
Technical Product Specification
Spares, Parts List, and Configuration Guide
Server Configurator Tool
Software and Drivers
Content
In-depth technical information
Supported accessories and spares list
Tested peripherals and operating systems list
Tested memory list
Supported processors list
Up-to-date firmware, driver, and utility information
A link to the above documents, Server Configurator Tool, and the Software and Drivers
web page can be found at: http://support.intel.com/support/motherboards/server/s5520ur/

Summary of content (1 pages)