Intel® Server System SR2612UR Service Guide A Guide for Technically Qualified Assemblers of Intel® Identified Subassemblies/ Products Intel Order Number E76206-004 Intel® Server System SR2612UR Service Guide i
Disclaimer Information in this document is provided in connection with Intel® products. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document.
Preface About this Manual Thank you for purchasing and using the Intel® Server System SR2612UR. This guide assumes you are familiar with Serial ATA (SATA) technology, SAS (Serial Attached SCSI), computer hardware, data storage, and network administration terminology and tasks. This manual is written for system technicians who are responsible for troubleshooting, upgrading, and repairing this server system.
Chapter 2 describes the features of your Intel® Server System SR2612UR and shows you how you can upgrade your system as your storage requirements change. It also lists the contents of the storage application array package, and describes additional hardware requirements. Chapter 3 provides instructions for adding and replacing components. It provides step-bystep instructions and diagrams for installing or replacing components such as the fans, power supply, drives, and other components.
Safety Information Before you begin the assembly process, you will need to make sure you follow certain basic safety precautions. Important Safety Instructions Read all caution and safety statements in this document before performing any of the instructions. See also Intel Server Boards and Server Chassis Safety Information on the Intel® Server Deployment Toolkit 3.0 CD and/or at http://www.intel.com/support/motherboards/server/sb/cs-010770.
Warnings Heed safety instructions: Before working with your server product, whether you are using this guide or any other resource as a reference, pay close attention to the safety instructions. You must adhere to the assembly instructions in this guide to ensure and maintain compliance with existing product certifications and approvals. Use only the described, regulated components specified in this guide.
Contents Preface ........................................................................................................................ iii About this Manual ................................................................................................................. iii Terminology Used in this Guide ............................................................................................ iii Manual Organization ......................................................................................
Tools and Supplies Needed ........................................................................................ 29 System References ..................................................................................................... 29 Preparing for Installation ............................................................................................. 29 Installing Your Intel® Server System SR2612UR into a Rack (Optional) ............................ 30 Installing the Disk Drives ...................
Introduction ..........................................................................................................................75 Installing a Disk Drive in a Universal Drive Carrier ......................................................75 Installing a Blank Insert in a Universal Drive Carrier ...................................................77 Appendix B: Intel® Server Issue Report Form ....................................................... 79 Appendix C: LED Decoder ...........................
Equipment Handling Practices .................................................................................. 124 Power and Electrical Warnings ................................................................................. 125 Access Warnings ...................................................................................................... 125 Electrostatic Discharge (ESD) ................................................................................... 126 Other Hazards .........................
List of Figures Figure 1. Intel® Server System SR2612UR Front View ............................................................ 2 Figure 2. Intel® Server System SR2612UR Rear View............................................................. 3 Figure 3. Intel® Server System SR2612UR Drive Carrier Assembly ........................................ 4 Figure 4. Intel® Server System SR2612UR Drive Slots ............................................................ 4 Figure 5.
Figure 43. Routing the Cables Through the Fan Assembly .................................................... Figure 44. Mounting an External Battery ................................................................................ Figure 45. Removing the Power Supply ................................................................................. Figure 46. Removing the Main Power Connector from the Backplane ................................... Figure 47.
List of Tables Server System References ....................................................................................................... 7 Intel® Server System SR2612UR Feature Summary ..............................................................10 Setup Menu Key Use ..............................................................................................................69 LED Decoder ...............................................................................................................
xiv Intel® Server System SR2612UR Service Guide
1 Server System Contents and References Server System Contents The Intel® Server System SR2612UR ships with the Intel® Server Board S5520UR. For information about the server board, see the Intel® Server Board SR2612UR Technical Product Specification. The contents of the Intel® Server System SR2612UR are listed in the following section.
• Minimum length: 0.5 m • Maximum length: 10 m For updated disk drive information or to purchase qualified disk drives or SAS cables, contact your Intel sales representative. Appliance Components and Features The main features of the appliance are shown in the following figures. System Front View Figure 1.
System Rear View Figure 2. Intel® Server System SR2612UR Rear View Note: The SAS expansion port is either part of the PCI RAID adapter card or is a separate multi-port PCI SAS card. Currently, the qualified and supported PCI RAID card are Intel® RAID Controller SRCSASJV, Intel® RAID Controller SRCSASLS4I and Intel® RAID Controller SASWT4I. Please refer to the Intel Customer Support web site under the link for these RAID controllers at:http://www.intel.
Figure 3. Intel® Server System SR2612UR Drive Carrier Assembly Each drive carrier has three LEDs, which indicate status as described in “Monitoring the Disk Drives”. To maintain proper airflow and cooling inside the appliance, all drive slots must have either a disk drive carrier assembly populated with an actual disk or a special plastic drive blank installed.
Combining SATA and SAS Disk Drives If you are combining SAS and SATA disk drives in the same enclosure, use the following figures to plan where you will place the disk drives. These figures represent enclosures fully-loaded with disk drives. However, the same guidelines apply even if you are filling some of the drive slots with blank drive carriers. Recommended Disk Drive Configurations Figure 5.
Unsupported Disk Drive Combinations Figure 6.
Additional Information and Software If you need more information about these products or information about the accessories that can be used with these server systems, use the following resources. Table 1.
Table 1. Server System References For this information or software Latest drivers, firmware updates (BIOS, BMC, and FRUSDR), and utilities Use this Document or Software Available for download at: http://www.intel.com/support/motherboards/server/sr2612ur/ Click the “Software and Drivers” link on the left side of the web page. To make sure your system falls within the allowed power budget Power Budget Analysis Tool Available at: http://www.intel.
2 Server System Features This chapter briefly describes the main features of the Intel® Server System SR2612UR. This includes illustrations of the products, a list of the server system features, and diagrams showing the location of important components and connections on the server systems. Figure 7.
Server System Feature Overview Table 2 summarizes the features of the server systems. Table 2. Intel® Server System SR2612UR Feature Summary Feature Dimensions Description • • • • • 3.43 inches (87 mm) high 17.57 inches (446 mm) wide Rack Mounting Surface to Rear I/O Tray Module Handle – 30.79 inches (781.5 mm) deep Front Surface of Disk Drive to Rear I/O Tray Module – 32.01 inches (812.4 mm) deep 67 pounds (30.
Table 2. Intel® Server System SR2612UR Feature Summary Feature Peripheral Interfaces Description External connections: • • • • • • • • • • • • • • • • Video Four USB 2.0 connectors (back) RJ-45 serial Port A connector Two RJ-45 10/100/1000 Mb Network connections DB-15 video connector (front and back) Internal connections: One USB 2x5 pin header, which supports two USB 2.
Table 2. Intel® Server System SR2612UR Feature Summary Feature LEDs and displays Description • • • • • • • Power LED Standby Power LED ( +3.
Figure 8.
Intel® Server System SR2612UR Components A - POWER SUPPLY B - POWER DIST BOARD C - PCI RISER ASSY D - SERVER BOARD E - BACKPLANE PCB F - HARD DRIVE ASSY K E B J A C I D G H G - SYSTEM AIR DUCT H - FAN MODULE I - 2.5” SYSTEM DRIVES F OPTIONAL HARDWARE J - RAID CARD BATTERY K - CD/DVD DRIVE A. Power Supply G. System Air Duct B. Power Distribution Board H. Fan Module C. PCI Riser Assembly I. 2.5-inch System Drives D. Server Board J. RAID Card Battery (Optional) E. Backplane PCB K.
Intel® Light-Guided Diagnostics The server system contains the following diagnostic LEDs, each providing the following functions: • The System Power LED on the front and back panels (see Figure 11 and Figure 12) shows the system power supplies status (off, green). • The Enclosure Services Subsystem fault LED on the front and back panels (See Figure 11 and Figure 12) shows health of the enclosure service subsystem (off, amber).
. A B C D E J F G J I H AF002833 A. POST Code Diagnostic LEDs B. System Identification LED C. Status LED D. Memory 1 Fan Fault LED E. CPU 1 Fan Fault LED F. CPU 1 DIMM Fault LEDs G. CPU 2 Fan Fault LED H. Memory 2 Fan Fault LED I. CPU 2 DIMM Fault LEDs J. 5V Standby LED Figure 10.
Figure 11.
Item A. B. C. D. E. Function Color Standby Power OK LED (+3.3V) Green System Status LED Green System Status LED Amber System Identification LED Blue Power Switch N/A State Description Off AC Power Off On AC power on or DC power on Solid On System booted and ready Blink Degraded Blink Non-critical Solid On Critical, non-recoverable On Identify active through command Off No Identification N/A N/A Figure 12.
A B C D E FG H I EE DD CC J BB K AA Z Y X W V U T L S R QPO N M AF002696 Intel® Server System SR2612UR Service Guide 19
A. 280-pin Intel® Adaptive Slot B. POST Code Diagnostic LEDs C. Intel® RMM3 Header D. Processor 1 Socket E. Back Panel I/O Ports F. System Identification LED G. System Status LED H. Memory 1 Fan Header I. CPU 1 Fan Header J. Processor 1 DIMM slots K. Processor 2 DIMM slots L. Processor 2 Socket M. CPU 2 Fan Header N. Memory 2 Fan Header O. Bridge Board Connector (Intel® Server Chassis) P. Front Panel Connector Q. Fan Board Connector R. 2x4 Power Connector S.
Configuration Jumpers DCD to DTR Serial Port Configuration 3 J9A1 A BIOS Recover J1D4 2 4 DSR to DTR (factory default) E Normal 2 Recover 3 Password Clear J1E8 D Protect 2 Clear 3 BIOS Default J1E7 C Normal 2 3 Set Default BMC Force Update J1H2 B Disable 2 Enable 3 AF002832 Jumper Name Jumper Purpose A. Serial Port Configuration (J9A1) If pins 1-2 are jumpered, the DCD to DTR mode is enabled. These pins should be jumpered on 3-4 to operate in the DSR to DTR (default) mode. B.
Jumper Name E. BIOS Recover (J1D4) Jumper Purpose If pins 2-3 are jumpered, the system can only boot from EFIbootable recovery media with the recovery BIOS image. The main system BIOS will not boot. These pins should be jumpered on 1-2 for normal system operation. Figure 14. Configuration Jumpers Front of Intel® Server System SR2612UR Peripheral Devices The Intel® Server System SR2612UR provides locations and hardware for installing hard drives, CD-ROM drive, or DVD-ROM drive.
. A. Hot-Swap 3.5-inch Hard Drive Bays (12) B. Internal fixed 2.5-inch SATA Hard Drive Bays (2) C. Slimline SATA Optical Drive Bay (1) Figure 15. Optional Peripherals Hard Disk Drive Carriers The server system ships with 12 drive carriers for installing 12 SAS or Serial ATA (SATA) hot-swap drives.
Note: Drives can consume up to 17 watts of power each. Drives must be specified to run at a maximum ambient temperature of 45°C. Note: The Intel® Server System SR2612UR does not support all SAS or Serial ATA (SATA) hard drives. For a web link to a list of supported hard drives, see “Additional Information and Software” on page -7. Slimline Optical Drive Carrier The slimline optical drive carrier can be used with a single slimline optical drive.
Item A. B. C. D. E. Function Color Standby Power OK LED (+3.
SAS/SATA Midplanes The midplane serves as the primary interface between the server board, hot-swap backplane, and control panel. Only one midplane is offered for this system: • Active SAS midplane Note: SATA connectors 6 and 7 are not used in the Intel® Server System SR2612UR. Active Midplane The following diagram show the location for each connector found on the active midplane. A. SAS Connector B. Backplane Connector Figure 17.
Hot-Swap SAS/SATA Backplane The backplane serves as an interface between the midplane board and the system drives. The hot-swap backplane provides support for both SAS and SATA hard drives. There are no hard drive cables that connect to the backplane. All hard drive control signals are routed from the midplane board, which plugs directly into the backplane. A. SAS/SATA Hard Disk Drive Connectors Figure 18. 3.5-inch Hot-Swap SAS/SATA Backplane Components (Front View) A. Backplane Power Connector B.
RAID Support For RAID support on the active midplane, you should install an additional RAID controller. For information on configuring RAID, see the Intel® RAID Software User’s Guide that is included on the Intel® Server Deployment Toolkit 3.0 CD. Advanced Management Options Intel® Remote Management Module 3 The Intel® Remote Management Module 3 plugs into a dedicated connector on the server board and provides additional server management functionality to the server board.
3 Hardware Installations and Upgrades Before You Begin Before working with your server product, pay close attention to the “Safety Information” on page v at the beginning of this manual. Note: Whenever you service the system, you must first power down the server and unplug all peripheral devices and the AC power cord.
Installing Your Intel® Server System SR2612UR into a Rack (Optional) If you are not installing your appliance into a rack, skip the remainder of this section and go to “Installing the Disk Drives” on page 33. To install your appliance into a rack: 1. Ensure you have these rail kit components: — One right rail assembly — One left rail assembly — Ten 10-32 cage nuts (square hole cabinets) — Ten 10-32 speed nuts (round hole cabinets) — Ten 10-32 x 0.50 Phillips pan head screws 2.
Figure 21. Securing the Front and Rear Portions of the Rail Kit 4. Tighten the four screws on each rail's slider mechanism. Figure 22. Tightening the Screws on the Rail’s Slider Mechanism Caution: A fully loaded appliance is heavy. To avoid personal injury, have someone help you lift the appliance.
5. Slide the appliance onto the rails, then push it all the way back until the rackmount ears are flush against the vertical supports and the appliance rests completely on the rails. Figure 23. Sliding the Appliance onto the Rails 6. Secure both rackmount ears to the vertical supports using two of the 10-32 x .50inch screws and carefully snap the plastic rack ear covers in place as shown. The rack installation is complete.
Installing the Disk Drives Caution: Before installing new disk drives, acclimate them to room temperature. Store drives at room temperature for two hours prior to use. Note: To install a disk drive or plastic blank into a carrier, refer to “Drive Installation in the Drive Carrier” on page 75 in this manual. 1. Select an open drive slot. 2. Hold the disk drive so the LEDs are on the left and the lever is fully open. 3. Slide the disk drive into the drive slot until the lever starts to close. Figure 24.
Figure 25. Pushing the Lever Until It Meets the Latch on Left Side of the Drive Slot 5. Repeat for all remaining disk drives. Drive installation is easier when installing drives from right to left in the enclosure. Note: To maintain proper airflow and cooling, you must install a disk drive carrier populated with an actual disk drive or plastic drive blank assembly in every slot of the enclosure.
Removing a Disk Drive Carrier Assembly (or Drive Blank) Note: For disk drive installation instructions, see “Installing the Disk Drives” on page 33. Important Safety Precautions Before you remove a populated disk drive carrier, read these important notes: • To avoid data loss, stop all I/O activity on the disk drive before removing it. (Removing a disk drive during I/O activity could also hang the host system.) • Do not attempt to remove more than one disk drive or blank drive carrier at a time.
Figure 26. Pushing the Button on the Assembly 2. Gently pull open the lever. The drive carrier or drive blank unlocks. Figure 27. Drive Carrier Unlocked 3. If the enclosure is powered on, allow the disk drive to fully spin down (wait approximately 15-20 seconds). Warning: Removing a populated disk drive carrier before it has fully spun down may result in disk drive damage and possible personal injury. 4. Gently pull the disk drive carrier or drive blank out of the enclosure. 5.
Installing the Operating System The Intel® Server System SR2612UR is now ready to have the operating system installed. Please contact your IT representative to perform this installation or if you are installing it yourself, please follow the general guidelines below. 1. Connect the power cords to the rear of the unit. 2. Connect a monitor, keyboard, and mouse to the rear connections on the enclosure. 3. Turn on power to the enclosure by pressing the power button on the rear of the enclosure. 4.
Connecting Your Intel® Server System SR2612UR to a Host Server Connecting to the 1GE iSCSI LAN Data Ports Consult your operating system/software user guide for details on assigning LAN IP addresses to the integrated system 1GE iSCSI data ports. For iSCSI applications running on the Intel® Server System SR2612UR, Ethernet connectivity is required. The following figure illustrates a direct iSCSI connection between the host system and one of the two Ethernet ports on the Intel® Server System SR2612UR.
Note: The dual 2.5-m power cords included with the Intel® Server System SR2612UR have domestic North American NEMA 5-15 plugs. If required, you can obtain International power cords locally (for example, via the Internet at http://www.interpowers.com). Figure 29. Powering-On 2. Press the Master Power Switch to power on the unit. Note: Note: On power up the internal server board on the Intel® Server System SR2612UR may take a couple of minutes to complete initialization and operating system boot activities.
5. Remove the drive sled by loosening the captive thumbscrew. Figure 30. Removing the drive sled 6. Position the drive(s) as shown and secure using the 4 screws provided with the drive. If installing only one drive, locate the drive on the bottom shelf of the sled. Figure 31. Installing the boot drives 7. Reinstall the drive sled and tighten down the captive thumbscrew. 8. The power cables for the 2.5-inch drives are located near the drive sled. Attach the cable(s) to the drive(s). 9.
10. Using the SATA cable supplied with the drive, route the cable from each disk drive to the CPU server board SATA connectors. Figure 32. Connections Diagram 11. Carefully reinstall the CPU server board air duct. 12. Reinstall the top cover and tighten the captive screw. 13. Reinstall the power cord(s). DVD Installation The Intel® Server System SR2612UR supports an optional DVD. Complete the following steps to install a DVD drive in the Intel® Server System SR2612UR. 1.
Figure 33. Removing the four screws and cover plate 6. Looking into the top of the enclosure, locate the DVD tray screw and remove. This screw will be re-used. Figure 34. Removing the four screws and cover plate 7. Slide the DVD tray out of the enclosure. 8. Position the DVD unit as shown in the following figure and carefully snap the unit in place by aligning the pointed tabs with the screw holes on the DVD unit.
Figure 35. Position the DVD Unit 9. Slide the DVD / tray assembly back into the enclosure and anchor it using the screw that was removed in Step 7. 10. Using the slimline cable shipped with the system, connect the power end of slimline cable to the power cable located in the enclosure and the SATA end of slimline cable to the CPU server board. If 2.5-inch drives are installed, connect the SATA cable to the SATA2 connector. Figure 36. Routing the Cable From the DVD Unit to the Server Board 11.
1. Ensure the AC power cord(s) are disconnected from the enclosure. 2. Remove the top cover from the enclosure by loosening the captive screw with a phillips screwdriver on the right-rear of the enclosure. 3. Slide the top cover back and lift it from the enclosure. 4. If the defective fan is located on the server board side of the enclosure, carefully remove the system air duct to allow access to the fan (reference item G on the System component diagram). 5.
Midplane Board Replacement Complete the following steps to remove and install an midplane in the Intel® Server System SR2612UR. 1. Ensure the AC power cord(s) are disconnected from the enclosure. 2. Remove the top cover from the enclosure by loosening the captive screw with a Phillips screwdriver on the right-rear of the enclosure. 3. Slide the top cover back and lift it from the enclosure. 4. Locate the midplane (located between the backplane and fans). Figure 38. Midplane 5.
7. Carefully disconnect the midplane from the backplane as shown in the following figure. Figure 39. Disconnecting the Midplane from the Backplane 8. Carefully connect the new midplane to the backplane. 9. Reinstall the two screws to hold the midplane in place. Be careful not to overtighten the screws. 10. Reconnect the I/O SAS cable by gently inserting into the metal socket. Ensure the cable was reinstalled correctly. 11. Reinstall the top cover and tighten the captive screw. 12.
To replace or add memory to the Intel® Server System SR2612UR, complete the following steps. 1. Ensure that the AC power cord(s) are disconnected from the enclosure. 2. Remove the top cover from the enclosure by loosening the captive screw with a Phillips screwdriver on the right-rear of the enclosure. 3. Slide the top cover back and lift it from the enclosure. 4. Carefully remove the system air duct over the CPU server board. 5.
Note: The DIMMs are “keyed” so they can only be inserted one way in the socket. Figure 41. Installing a DIMM 7. Once the DIMMs are installed, carefully replace the system air duct over the server board. 8. Reinstall the top cover and tighten the captive screw. 9. Reinstall the power cord(s). PCI Card and Battery Installation The Intel® Server System SR2612UR supports to five PCI-E option cards. A typical configuration uses a PCI-E-based RAID card to communicate with the 12 drive slots.
Figure 42. Lifting the PCI Cage Assembly Out of the Enclosure 6. Remove the metal blank filler for the appropriate slot you will be plugging the card into (the top slot is used for the first installed card). 7. Carefully install the PCI card starting at the top slot of the PCI cage. PCI cards are keyed so they cannot be installed backwards. 8. To reinstall the PCI cage assembly, line up the tabs at the bulkhead cutouts on the rear of the enclosure. 9.
Figure 43. Routing the Cables Through the Fan Assembly 12. If there is an external battery associated with the PCI card, it must be mounted with the supplied mounting screws in the location indicated in the following figure A - POWER SUPPLY B - POWER DIST BOARD C - PCI RISER ASSY D - SERVER BOARD E - BACKPLANE PCB F - HARD DRIVE ASSY K E B J A C I D G H G - SYSTEM AIR DUCT H - FAN MODULE I - 2.5” SYSTEM DRIVES F OPTIONAL HARDWARE J - RAID CARD BATTERY K - CD/DVD DRIVE Figure 44.
14. Reinstall the power cord(s). Power Supply Replacement Complete the following steps to remove and install a power supply in the Intel® Server System SR2612UR. 1. Ensure the AC power cord(s) are disconnected from the enclosure. 2. Remove the top cover from the enclosure by loosening the captive screw on the right-rear of the enclosure with a Phillips screwdriver. 3. Slide the top cover back and lift it from the enclosure. 4.
Removing the Backplane Board Observe ESD precautions when servicing this unit. At a minimum, use an ESD grounded wrist strap when handling electrical components. Where possible utilize a grounded ESD mat to place drives and components on. For more information, refer to “Safety Information” on page 123. 1. Power down the enclosure and remove the power cord(s). 2. Remove all disk drives. Note their slot location in the enclosure. 3.
Figure 48. Removing the Midplane from the Enclosure 8. Using an extended Phillips head screwdriver reach in from the front of the enclosure and remove the seven (7) screws attaching the backplane Figure 49. Removing the Screws that Attach the Backplane 9. Carefully pull back on the top of the backplane and lift it out of the enclosure Figure 50.
Installing and Removing the RAID Battery Backup Unit Installing the RAID Battery Backup Unit (BBU) Warning: Observe ESD precautions when servicing this unit. At a minimum utilize an ESD grounded wrist strap when handling electrical components. Where possible utilize a grounded ESD mat to place drives and components on. To install the RAID battery backup unit, follow these steps: 1. Power down the enclosure and remove the power cord(s). 2. Remove all disk drives. Note their slot location in the enclosure. 3.
6. Remove the standoff from the battery plate as shown below. Figure 52. Remove the standoff 7. Align the battery pack as shown (with cable installed), and put into place by inserting the plastic tabs into the slots and sliding the pack in the direction of the arrow on the battery plate until the unit snaps into place. Figure 53.
Figure 54. Aligning the battery pack 8. Replace and tighten the standoff that was removed in step 6 Figure 55. Replace and tighten standoff 9. Route the cable from the battery pack as shown below. Figure 56.
10. Connect the cable to the installed PCI RAID board as shown below Figure 57. Connect the cable to PCI RAID Card 11. Reinstall the top cover and tighten the captive screw. 12. Reinstall the power cords. Installing and Removing the Server Board Removing the Server Board To remove the server board, follow these steps: 1. Power down the enclosure and remove the power cord(s). 2.
Figure 58. Disconnect the power cables 8. Disconnect fan cables, FAN 1, FAN 2, FAN 3 and FAN 4 from Motherboard as shown below Figure 59. Disconnect the fan cables 9. Remove memory. 10. Remove the processor heatsink(s) and processor(s). 11. Remove the nine screws from the server board and lift the server board from the server system as shown below.
Figure 60. Remove the screws 12. Install the replacement server board.
Installing the Server Board To install the server board, follow these steps: 1. Install Motherboard into chassis by tilting the board and inserting the connectors into the proper openings on the rear bulkhead as shown below. When the connectors are placed into the proper openings, slowly place the board into the chassis without causing any damage to the bottom side components. Figure 61. Installing the server board 2. Attach the server board with nine screws. Figure 62.
3. Install power cables, P1, P2, P3 and Front Panel logic cable, into Motherboard as shown below. Figure 63. Installing power cables 4. Install fan cables, FAN 1, FAN 2, FAN 3 and FAN 4 into Motherboard as shown below. Figure 64. Install the fan cables 5. Install memory. 6. Install the processor(s). 7. Install processor heatsink(s). 8. If necessary, install the Intel® RMM3. 9. Install the PCI riser assembly. 10. Install the processor air duct. 11. Install the top cover and tighten the captive screw. 12.
Replacing the Backup Battery The lithium battery on the server board powers the RTC for up to 10 years in the absence of power. When the battery starts to weaken, it loses voltage, and the server settings stored in CMOS RAM in the RTC (for example, the date and time) may be wrong. Contact your customer service representative or dealer for a list of approved devices. Warning: Danger of explosion if battery is incorrectly replaced.
Removing and Installing the Power Distribution Module Removing the Power Distribution Module To remove the server board, follow these steps: 1. Power down the enclosure and remove the power cord(s). 2. Remove the top cover from the enclosure by loosening the captive screw with a Phillips screwdriver on the right-rear of the enclosure. 3. Slide the top cover back and lift it from the enclosure. 4. Remove the processor air duct. 5. Remove the PCI riser assembly. 6.
7. Remove 2 screws from nylon clamps and disconnect power cable “P4” from backplane as shown below. Figure 66. Remove the screws 8. Remove cable chase insert foam from cable chase fan blank and then remove power cable p4 from cable chase fan blank as shown below. Figure 67.
9. Remove the four screws from the power distribution module and lift the power distribution module from the server system as shown below. Figure 68. Remove the four screws from the PDB 10. Install the replacement power distribution module. Installing Power Distribution Module 1. Install power distribution module onto spacers and Install all four screws as shown below. Figure 69. Installing the Power Distribution Module 2. Route cable marked “P4” through the cable chase fan blank as shown below.
Figure 70. Route cable P4 3. Install 2 nylon clamps onto cable “P4”, flat side up as shown below. Figure 71. Install the nylon clamps 4. Connect power cable “P4” into backplane and Install 2 screws into nylon clamps and secure to chassis as shown below.
Figure 72. Connecting cable P4 to backplane 5. Insert cable chase insert foam into cable chase fan blank. See picture below for foam orientation. Figure 73.
6. Install power cables, P1, P2, P3 and Front Panel logic cable, into Motherboard as shown below. Figure 74. Install the power cables 7. Install the PCI riser assembly. 8. Install the processor air duct. 9. Install the top cover and tighten the captive screw. 10. Install the power cords.
4 Server Utilities Using the BIOS Setup Utility This section describes the BIOS Setup utility options, which is used to change server configuration defaults. You can run the BIOS Setup with or without an operating system being present. For information about specific BIOS setup screens, see the Intel® Server Board S5520UR Technical Product Specification. For a web link to this document, see “Additional Information and Software” on page 7.
Table 3. Setup Menu Key Use Key to Press Description Left and right arrows Select Menu - The left and right arrow keys are used to move between the major menu pages. The keys have no affect if a submenu or pick list is displayed. Up arrow Select Item up - The up arrow is used to select the previous value in a menu item's option list, or a value field’s pick list. Pressing the key activates the selected item.
Table 3. Setup Menu Key Use Key to Press Description Save and Exit - Pressing causes the following message to appear: Setup Confirmation Save Configuration changes and exit now? [Yes] [No] If "Yes" is selected and the key is pressed, all changes are saved and Setup is exited. If "No" is selected and the key is pressed, or the key is pressed, you are returned to the screen that you were in before was pressed without affecting any existing values.
Note: Do not skip step 2. You will need these settings to configure your server at the end of the procedure. Obtaining the Upgrade Download the BIOS image file to a temporary folder on your hard drive. See “Additional Information and Software” on page 7 for a web link to the update software. Note: Review the instructions and release notes that are provided in the readme file distributed with the BIOS image file before attempting a BIOS upgrade.
The password is now cleared and can be reset by going into the BIOS setup.
Restoring the BIOS Defaults If you need to restore the BIOS default settings, the BIOS Default jumper will need to be used. 1. Power down the system; do not disconnect the AC power. 2. Open the server system. For instructions on removing the system cover, see “Removing the System Cover” on page 48. 3. Locate the BIOS Default jumper block at board position J1E7. 4. Move the jumper from the normal operation position (covering pins 1 and 2) to the Set Default position (covering pins 2 and 3). 5.
Appendix A: Drive Installation in the Drive Carrier Introduction The Intel® Server System SR2612UR universal drive carrier is either used for mounting drives into an enclosure or is used with a blank insert (no drive installed) to maintain proper cooling. This appendix covers the installation of a disk drive in the universal drive carrier. Caution: Acclimate new disk drives to room temperature for at least two hours prior to use. Caution: Be sure to take antistatic precautions when handling disk drives.
Figure 75. Installing a Disk Drive in a Universal Carrier 2. Do not discard the screws as you will use them to install the disk drive. 3. You can discard or retain the plastic spacer depending on whether you will use blanks at a later time in the enclosure. 4. Position the disk drive with the connector towards the rear of the carrier and the disk drive label on top per the illustration below. There are two sets of mounting holes on the carrier.
Figure 76. Installing the Four Screws into the Drive Carrier 5. Insert and hand tighten the four (4) 6 x 32 x .25-inch screws. Do not overtighten the screws as this may strip the threads on either the screw or the disk drive. 6. You can now install the drive into the enclosure.
Figure 77. Orienting the Plastic Insert with the Drive Carrier 2. Carefully install the four (4) 6 x 32 x .25-inch screws supplied with the carrier. Do not overtighten.
Appendix B: Intel® Server Issue Report Form Issue Report Form (Rev 3.6) Note: Filling out this form completely is required for any escalation. =============================================================== Customer Contact Information: Customer Support Case #: =============================================================== Intel® Server Board or System: (Example: S5000PSL or SR6850HW4) =============================================================== Server Chassis: (Example SC5400.
Has the latest BMC/mBMC been tried? (Yes/No): Has the latest IMM BMC been tried? (Yes/No): Has the latest RMM Firmware been tried? (Yes/No): Has the latest FRU/SDR been tried? (Yes/No): Has the latest HSC been tried? (Yes/No): =============================================================== Processor information: Type Speed sSpec Thermal Solution Processor 1 Processor 2 Processor 3 Processor 4 Thermal solution (Heatsink) examples: (1U, Passive w/air ducting, Active w/fan, etc.
Add-in adapters (Example: NICs, Management Adapters, Serial Expansion Cards, PCI-Express* Adapters, RAID Controllers, SCSI Controllers, etc.): Type Slot Manufacturer Model Firmware Third party hardware Example KVM, Chassis, and so forth): Description/Use Manufacturer Model Firmware Storage Devices (Example: SCSI, SATA, SAS, USB, Tape, etc.
Intel® RAID Controller: (Example SRCU42E) RAID controller part number (PBA number): RAID controller firmware version: Has the latest RAID firmware been tried? (Yes/No): RAID driver version: Has the latest RAID driver been tried? (Yes/No): RAID volumes configuration (disks & RAID level): RAID volume use (Boot device/Data Volume): Is BBU (Battery Backup Unit) installed? (Yes/No): BBU part number: =============================================================== Detailed description of issue: Troubleshooting t
Steps to replicate the issue: =============================================================== Issue impact statements: Do you have any potential Intel system, or component purchases that this issue is holding up? If yes, please provide a brief description below. Do you have systems already purchased that are not being delivered to your customers because of this issue? If yes, please provide a brief description below.
84 Intel® Server System SR2612UR Service Guide
Appendix C: LED Decoder Appliance Status On the right front side of the Intel® Server System SR2612UR are four LEDs which indicate the status of the appliance. Figure 78. LED Statuses The following table describes what each LED indicates: When a failure occurs within the system, the System Fault LED illuminates. Table 4.
Figure 79. LED Board The following table describes the LED Board LEDs. Table 5. LED Board LEDs Descriptions LED Color Standby Power OK Green System Status LED Green Green System Status LED Amber Amber System Identify Blue Description Indicates the power is okay Enclosure ID Monitoring the Disk Drives Each populated disk drive carrier has three LEDs that indicate the status of the disk drive, as described in the following table. Figure 80. Disk Drive LEDs Table 6.
Table 6. LED Status for the Disk Drive LED Condition Color 2 Disk Status Green/Amber 3 Disk Activity Green Table 7.
88 Intel® Server System SR2612UR Service Guide
Appendix D: Getting Help If you encounter an issue with your server system, follow these steps to obtain support: 1. Visit the following Intel support web page: http://www.intel.com/support/motherboards/server/ This web page provides 24x7 support when you need it to get the latest and most complete technical support information on all Intel Enterprise Server and Storage Platforms.
90 Intel® Server System SR2612UR Service Guide
Appendix E: Regulatory and Certification Information Warning: To ensure regulatory compliance, you must adhere to the assembly instructions in this guide to ensure and maintain compliance with existing product certifications and approvals. Use only the described, regulated components specified in this guide.
• IEC60950-1 (International) • CB Certificate & Report, IEC60950 (report to include all country national deviations) • • • • • • GS Certification (Germany – EN60950-1) GOST R 50377-92 - Certification (Russia) Ukraine Certification (Ukraine) CE Declaration to EU Low Voltage Directive 2006/95/EC (Europe – EN60950-1) IRAM Certification (Argentina) BSMI RPC Certification (Taiwan) Product EMC Compliance - Class A Compliance • • • • • • • • • • • • • • • 92 FCC – Part 15 Emissions (USA) Verification ICES-003
Product Ecology Compliance Intel has a system in place to restrict the use of banned substances in accordance with world wide regulatory requirements. A Material Declaration Data Sheet is available for Intel products. For more reference on material restrictions and compliance you can view Intel's Environmental Product Content Specification at http://supplier.intel.com/ehs/environmental.htm.
• KCC Certification (Korea) • IRAM Certification (Argentina) • Ecology Declaration (International) • China RoHS Environmental Friendly Use Period • Packaging & Product Recycling Marks 94 Intel® Server System SR2612UR Service Guide
Product Regulatory Compliance Markings This Intel Server Chassis product if provided with the following regulatory and safety markings. In the event there is no room for a marking(s) on the chassis, the information is provided here in this guide . Table 8.
Table 8.
Table 8. Product Regulatory Compliance Markings Regulatory Compliance Country Waste of Electronic and Electrical Equipment Recycling Mark Europe China Restriction of Hazardous Substance Environmental Friendly Use Period Mark China China Recycling Mark China Recycling Marks International Battery Perchlorate Warning Information California Marking Perchlorate Material - Special handling may apply. See www.dtsc.ca.
Table 8. Product Regulatory Compliance Markings Regulatory Compliance Safety Country Marking Multiple Power Cord Marking This unit has more than one power supply cord. To reduce the risk of electrical shock, disconnect (2) two power supply cords before servicing. Simplified Chinese: Traditional Chinese: German: Dieses Geräte hat mehr als ein Stromkabel. Um eine Gefahr des elektrischen Schlages zu verringern trennen sie beide (2) Stromkabeln bevor Instandhaltung.
Rack Mount Installation Guidelines Anchor the equipment rack: The equipment rack must be anchored to an unmovable support to prevent it from falling over when one or more servers are extended in front of the rack on slides. You must also consider the weight of any other device installed in the rack. A crush hazard exists should the rack tilt forward which could cause serious injury.
Main DC power disconnect: You are responsible for installing a properly rated DC power disconnect for the server system. This mains disconnect must be readily accessible, and it must be labeled as controlling power to the server. The circuit breaker of a centralized DC power system may be used as a disconnect device when easily accessible and should be rated no more than 10 amps.
Electromagnetic Compatibility Notices FCC Verification Statement (USA) This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. For questions related to the EMC performance of this product, contact: Intel Corporation 5200 N.E.
ICES-003 (Canada) Cet appareil numérique respecte les limites bruits radioélectriques applicables aux appareils numériques de Classe A prescrites dans la norme sur le matériel brouilleur: "Apparelis Numériques", NMB-003 édictee par le Ministre Canadian des Communications.
BSMI (Taiwan) The BSMI Certification Marking and EMC warning is located on the outside rear area of the product. KCC (Korea) Following is the KCC certification information for Korea. English translation of the notice above: 1. Type of Equipment (Model Name): On License and Product 2. Certification No.: On RRL certificate. Obtain certificate from local Intel representative 3. Name of Certification Recipient: Intel Corporation 4. Date of Manufacturer: Refer to date code on product 5.
If you do not have access to Intel's Web address, please contact your local Intel representative. • Server Chassis: (base chassis is provided with power supply and fans) - NRTL listed. • Server board: you must use an Intel server board - UL recognized. • Add-in boards: must have a printed wiring board flammability rating of minimum UL94V-1. Add-in boards containing external power connectors and/or lithium batteries must be UL recognized or UL listed.
Appendix F: Installation/Assembly Safety Instructions English The power supply in this product contains no user-serviceable parts. Refer servicing only to qualified personnel. Do not attempt to modify or use the supplied AC power cord if it is not the exact type required. A product with more than one power supply will have a separate AC power cord for each supply. The power button on the system does not turn off system AC power.
After you have completed the six SAFETY steps above, you can remove the system covers. To do this: 1. Unlock and remove the padlock from the back of the system if a padlock has been installed. 2. Remove and save all screws from the covers. 3. Remove the cover(s). For proper cooling and airflow, always reinstall the chassis covers before turning on the system. Operating the system without the covers in place can damage system parts. To install the covers: 1.
The system is designed to operate in a typical office environment. Choose a site that is: • Clean and free of airborne particles (other than normal room dust). • Well ventilated and away from sources of heat including direct sunlight. • Away from sources of vibration or physical shock. • Isolated from strong electromagnetic fields produced by electrical devices.
SICHERHEISMASSNAHMEN: Immer wenn Sie die Gehäuseabdeckung abnehmen um an das Systeminnere zu gelangen, sollten Sie folgende Schritte beachten: 1. Schalten Sie alle an Ihr System angeschlossenen Peripheriegeräte aus. 2. Schalten Sie das System mit dem Hauptschalter aus. 3. Ziehen Sie den Stromanschlußstecker Ihres Systems aus der Steckdose. 4. Auf der Rückseite des Systems beschriften und ziehen Sie alle Anschlußkabel von den I/O Anschlüssen oder Ports ab. 5.
Der Mikroprozessor und der Kühler sind möglicherweise erhitzt, wenn das System in Betrieb ist. Außerdem können einige Platinen und Gehäuseteile scharfe Spitzen und Kanten aufweisen. Arbeiten an Platinen und Gehäuse sollten vorsichtig ausgeführt werden. Sie sollten Schutzhandschuhe tragen. Bei falschem Einsetzen einer neuen Batterie besteht Explosionsgefahr. Die Batterie darf nur durch denselben oder einen entsprechenden, vom Hersteller empfohlenen Batterietyp ersetzt werden.
Ne pas essayer d'utiliser ni modifier le câble d'alimentation CA fourni, s'il ne correspond pas exactement au type requis. Le nombre de câbles d'alimentation CA fournis correspond au nombre de blocs d'alimentation du produit Notez que le commutateur CC de mise sous tension /hors tension du panneau avant n'éteint pas l'alimentation CA du système. Pour mettre le système hors tension, vous devez débrancher chaque câble d'alimentation de sa prise.
Afin de permettre le refroidissement et l'aération du système, réinstallez toujours les panneaux du boîtier avant de mettre le système sous tension. Le fonctionnement du système en l'absence des panneaux risque d'endommager ses pièces. Pour installer les panneaux, procédez comme suit: 1. Assurez-vous de ne pas avoir oublié d'outils ou de pièces démontées dans le système. 2. Assurez-vous que les câbles, les cartes d'extension et les autres composants sont bien installés. 3.
Español El usuario debe abstenerse de manipular los componentes de la fuente de alimentación de este producto, cuya reparación debe dejarse exclusivamente en manos de personal técnico especializado. Puede que este producto disponga de más de una fuente de alimentación No intente modificar ni usar el cable de alimentación de corriente alterna, si no corresponde exactamente con el tipo requerido.
Después de completar las seis instrucciones de SEGURIDAD mencionadas, ya puede extraer las tapas del sistema. Para ello: 1. Desbloquee y extraiga el bloqueo de seguridad de la parte posterior del sistema, si se ha instalado uno. 2. Extraiga y guarde todos los tornillos de las tapas.Extraiga las tapas. Para obtener un enfriamiento y un flujo de aire adecuados, reinstale siempre las tapas del chasis antes de poner en marcha el sistema.
El sistema está diseñado para funcionar en un entorno de trabajo normal. Escoja un lugar: • "Limpio y libre de partículas en suspensión (salvo el polvo normal). • "Bien ventilado y alejado de fuentes de calor, incluida la luz solar directa. • "Alejado de fuentes de vibración. • "Aislado de campos electromagnéticos fuertes producidos por dispositivos eléctricos.
Italiano Rivolgersi ad un tecnico specializzato per la riparazione dei componenti dell'alimentazione di questo prodotto. È possibile che il prodotto disponga di più fonti di alimentazione. Non modificare o utilizzare il cavo di alimentazione in c.a. fornito dal produttore, se non corrisponde esattamente al tipo richiesto. Ad ogni fonte di alimentazione corrisponde un cavo di alimentazione in c.a. separato L'interruttore attivato/disattivato nel pannello anteriore non interrompe l'alimentazione in c.a.
Per il giusto flusso dell'aria e raffreddamento del sistema, rimettere sempre le coperture del telaio prima di riaccendere il sistema. Operare il sistema senza le coperture al loro proprio posto potrebbe danneggiare i componenti del sistema. Per rimettere le coperture del telaio: 1. Controllare prima che non si siano lasciati degli attrezzi o dei componenti dentro il sistema. 2. Controllare che i cavi, dei supporti aggiuntivi ed altri componenti siano stati installati appropriatamente. 3.
System Specifications This appendix lists the system specifications for the Intel® Server System SR2612UR.
Redundant Hot-swappable Components • Two power supply modules • Two independent AC power inlets with domestic NEMA power cords • Up to 12 drives Maximum Cable Lengths (Customer Supplied) • 3 Gbps SAS: Up to 6m • 1 Gb Ethernet: up to 10m Raid Features • RAID 0,1,10,5,50,6,60 (PCI RAID adapter dependant) • OS software RAID capable • Auto-negotiate speeds • In-band and out-of-band management • SAS/SMP/SSP protocol support • Redundant cable support 2U Rackmount Enclosure • Dimensions: 3.5 inches H x 17.
AC Power • Input voltage: Auto ranging, 90-264VAC • Input frequency: 47-63 Hz • Power factor correction: Per EN61000-3-2 • Input current: 8.8 Amps RMS max @ 100VAC • Output power: 760 W peak • Efficiency: 91% @ 230VAC, 50% load • Variable speed “smart fans” Supported Options • One DVD drive • Up to five PCI-E expansion cards • Up to two 2.
Optional DVD • Internally mounted slim DVD with SATA interposer card/cable (rear accessible) Electromagnetic Emissions and Immunity Standards • CE Mark, EN55022/EN61000 Class A • FCC Class A, Canadian IECS-003 • VCCI Class A Safety Standards • UL 60950, CSA 22.
Monitoring • Temperature, power supply modules, fan speed control, disk drives and I/O module(s), as well as error rates and quality of service Qualifications For Newisys qualifications relative to supported options for specific disk drives, software application environments, PCI adapters, and so on, go to www.newisys.com/support.
122 Intel® Server System SR2612UR Service Guide
G Safety Information English Server Safety Information This document applies to Intel® server boards, Intel® server chassis and installed peripherals. To reduce the risk of bodily injury, electrical shock, fire, and equipment damage, read this document and observe all warnings and precautions in this guide before installing or maintaining your Intel® server product.
Indicates hot components or surfaces. Indicates do not touch fan blades, may result in injury. Indicates to unplug all AC power cord(s) to disconnect AC power Please recycle battery Intended Application Uses This product was evaluated as Information Technology Equipment (ITE), which may be installed in offices, schools, computer rooms, and similar commercial type locations.
• Use mechanical assistance or other suitable assistance when moving and lifting equipment. • To reduce the weight for easier handling, remove any easily detachable components. Power and Electrical Warnings Caution: The power button, indicated by the stand-by power marking, DOES NOT completely turn off the compute module AC power, 5V standby power is active whenever the compute module is plugged in. To remove power from compute module, you must unplug the AC power cord from the wall outlet.
• When replacing a hot-plug power supply, unplug the power cord to the power supply being replaced before removing the power supply from the chassis. Caution: If the compute module has been running, any installed processor(s) and heat sink(s) may be hot. Unless you are adding or removing a hot-plug component, allow the compute module to cool before opening the covers.
Laser Peripherals or Devices Caution: To avoid risk of radiation exposure and/or personal injury: • Do not open the enclosure of any laser peripheral or device • Laser peripherals or devices have are not user serviceable • Return to manufacturer for servicing Deutsch Sicherheitshinweise für den Server Das vorliegende Dokument bezieht sich auf Intel® Serverplatinen, Intel® Servergehäuse (Standfuß und Rack) sowie installierte Peripheriegeräte.
Weist auf potentielle Gefahr bei Nichtbeachtung der angezeigten Informationen hin. Weist auf die Gefahr eines Stromschlags hin, der bei Nichtbeachtung der Sicherheitshinweise zu schweren oder tödlichen Verletzungen führen kann. Weist auf Verbrennungsgefahr an heißen Bauteilen bzw. Oberflächen hin. Weist darauf hin, daß das Anfassen des Gebläses zu Verletzungen führen kann. Bedeutet, alle Netzkabel abzuziehen und das Gerät von der Netzspannung zu trennen.
Handhabung von Geräten Beachten Sie zur Vermeidung von Verletzungen oder Beschädigungen an den Geräten die folgenden Hinweise: • Halten Sie beim Transportieren und Anheben von Geräten die örtlichen Gesundheitsund Sicherheitsvorschriften ein. • Verwenden Sie mechanische oder andere geeignete Hilfsmittel zum Transportieren oder Anheben von Geräten. • Entfernen Sie alle Komponenten, die sich leicht abnehmen lassen, um das Gewicht zu reduzieren und die Handhabung zu erleichtern.
Warnungen zu Netzspannung und Elektrizität Vorsicht: Durch Betätigen der mit dem Standby-Symbol gekennzeichneten Netztaste wird das System NICHT vollständig vom Netz getrennt. Es sind weiterhin 5 V aktiv, solange das System eingesteckt ist. Um das System vollständig vom Strom zu trennen, muß das Netzkabel aus der Steckdose abgezogen werden. Das System verfügt möglicherweise über mehrere Netzkabel. Vergewissern Sie sich in diesem Fall, daß alle Netzkabel abgezogen sind.
• Wenn Sie ein hot-plug-fähiges Netzteil austauschen, ziehen Sie dessen Netzkabel ab, bevor Sie es aus dem Server ausbauen. Vorsicht: War Ihr Server in Betrieb, können die installierten Prozessoren und Kühlkörper heiß sein. Sofern Sie keine Hot-Plug-Komponenten ein- oder ausbauen, warten Sie mit dem Abnehmen der Abdeckungen, bis das System abgekühlt ist. Gehen Sie beim Aus- oder Einbauen von Hot-Plug-Komponenten sorgfältig vor, um nicht mit heißen Komponenten in Berührung zu kommen.
Andere Gefahren Batterieaustausch Vorsicht: Wird die Batterie unsachgemäß ausgetauscht, besteht Explosionsgefahr. Verwenden Sie als Ersatz nur die vom Gerätehersteller empfohlene Batterie. Beachten Sie bei der Entsorgung von Batterien die gültigen Bestimmungen. Versuchen Sie nicht, eine Batterie aufzuladen. Versuchen Sie nicht, eine Batterie zu öffnen oder sonstwie zu beschädigen.
Français Consignes de sécurité sur le serveur Ce document s’applique aux cartes serveur Intel®, au châssis de serveur Intel® (sur pieds et sur rack) et aux périphériques installés. Pour réduire les risques de dommages corporels, d’électrocution, d’incendie et de dommages matériels, lisez ce document et respectez tous les avertissements et précautions mentionnés dans ce guide avant d’installer ou de mettre à jour votre produit serveur Intel®.
Indique de débrancher tous les cordons d’alimentation secteur pour déconnecter l’alimentation. Veuillez réutiliser la batterie Domaines d’utilisation prévus Ce produit a été testé comme équipement informatique (ITE) et peut être installé dans des bureaux, des écoles, des salles informatiques et des endroits commerciaux similaires.
Alimentation et avertissements en matière d’électricité Attention: Le bouton d’alimentation, indiqué par le symbole de mise en veille, NE COUPE PAS complètement l’alimentation secteur du système car le courant de veille 5 V reste actif lorsque le système est sous tension. Pour couper l’alimentation du système, vous devez débrancher le cordon d’alimentation secteur de la prise murale. Votre système peut utiliser plusieurs cordons d’alimentation secteur.
Attention: Si le serveur a été utilisé, les processeurs et dissipateurs de chaleur installés peuvent être chauds. À moins que vous n’ajoutiez ou ne retiriez un composant connectable à chaud, laissez le système refroidir avant d’ouvrir les panneaux. Pour éviter tout risque d’entrer en contact avec un composant chaud lors d’une installation à chaud, prenez toutes les précautions nécessaires lorsque vous retirez ou installez des composants connectables à chaud.
• Vérifiez tout d’abord que vous n’avez pas oublié d’outils ou de composants détachés à l’intérieur du système. • Vérifiez que les câbles, les cartes d’extension et les autres composants sont correctement installés. • Fixez les panneaux au châssis en suivant les instructions du produit. Périphériques laser Attention: Pour éviter tout risque d’exposition aux rayonnements et/ou de dommage personnel: • N’ouvrez pas l’enceinte d’un périphérique laser.
PRECAUCIÓN ADVERTENCIA Indica la existencia de un riesgo que podría causar lesiones personales o daños en la propiedad leves si no se tiene en cuenta la PRECAUCIÓN. Indica la existencia de un riesgo que podría causar lesiones personales graves si no se tiene en cuenta la ADVERTENCIA. Indica un riesgo potencial si no se tiene en cuenta la información indicada. Indica riesgo de descargas eléctricas que podrían causar lesiones graves o la muerte si no se siguen las instrucciones de seguridad.
• En zonas propensas a tormentas eléctricas, se recomienda que conecte el servidor a un supresor de sobretensiones y desconecte las líneas de telecomunicaciones al módem durante una tormenta eléctrica. • Provista de una toma de corriente alterna correctamente conectada a tierra. • Provista de espacio suficiente para acceder a los cables de la fuente de alimentación ya que constituyen la desconexión principal de la alimentación.
puede haber niveles de tensión, corriente y energía peligrosos. Devuélvala al fabricante para repararla. Al reemplazar una fuente de alimentación de conexión en funcionamiento, desenchufe el cable de alimentación de la fuente de alimentación que va a reemplazar antes de extraerla del servidor. Para evitar el riesgo de descargas eléctricas, antes de abrir el servidor, apáguelo, desconecte el cable de alimentación, los sistemas de telecomunicaciones, las redes y los módems conectados al mismo.
de conexión en funcionamiento, tenga cuidado al extraer o instalar los componentes de conexión en funcionamiento. Precaución: Para evitar posibles daños, no toque las aspas en movimiento de los ventiladores. Si el sistema se le ha suministrado con una protección para el ventilador, asegúrese de que cuando esté funcionando el sistema la protección esté en su sitio. Descarga electrostática (ESD) Precaución: Las descargas electrostáticas pueden dañar las unidades de disco, las tarjetas y otros componentes.
Periféricos o dispositivos láser Precaución: Para evitar el riesgo de la exposición a radiaciones o de daños personales: • No abra la caja de ningún periférico o dispositivo láser • Los periféricos o dispositivos láser no pueden ser reparados por el usuario • Haga que el fabricante los repare.
简体中 文 服务器 安全信息 本 文档 适用 于 Intel® 服 务器 主板 、Intel® 服 务器 机箱 (基 座和 机架 固定 件) 和已 安装 的外 设。 为减 少人 身伤 害、 电 击、 火灾 以及 设备 毁坏 的危 险, 请在 安装 或维 护 Intel® 服 务器 产品 之前 阅读 本文 档并 遵循 本指 南中 的所 有警 告和 预防 措施 。 如 果本 文档 中的 信息 与特 定产 品的 随附 信息 或 Web 站 点信 息之 间存 在不 一致 ,请 以产 品文 档为 准。 服 务器 须由 合格 的技 术人 员进 行集 成和 维护 。 必 须遵 守本 指南 的规 定和 服务 器手 册的 装配 指导 ,以 确保 符合 现有 的产 品 认证 和审 批。 仅使 用本 指南 中描 述和 规定 的指 定组 件。 使用 其他 产品 / 组件 将使 产品 的 UL 认 证和 其他 管理 审批 无效 ,并 可能 导致 产品 不符 合销 售地 的产 品法 规。 安全警 告与注意 事项 为 避免 人身 伤害 与财 产损 失, 安装 本产 品之 前, 请阅 读以 下所 有安 全指 导 和信 息。 下面 所列 的
144 Intel® Server System SR2612UR Service Guide
Intel® Server System SR2612UR Service Guide 145
146 Intel® Server System SR2612UR Service Guide
Intel® Server System SR2612UR Service Guide 147
148 Intel® Server System SR2612UR Service Guide