Technical Advisory 948
This Technical Advisory describes an issue which may or may not affect the customer’s product
Intel Technical Advisory TA-0948-1
5200 NE Elam Young Parkway
Hillsboro, OR 97124
April 2, 2010
Copyright © 2010 Intel Corporation. * Other names and brands may be claimed as the property of others.
Intel® Server Systems SR1625, SR2600, and SR2625 may not be able
to load Linux OS or IDA from Optical Drive
Information in this document is provided in connection with Intel products. No license, express or implied, by estoppel or otherwise,
to any intellectual property rights is granted by this document. Except as provided in Intel's Terms and Conditions of Sale for such
products, Intel assumes no liability whatsoever, and Intel disclaims any express or implied warranty, relating to sale and/or use of
Intel products including liability or warranties relating to fitness for a particular purpose, merchantability, or infringement of any patent,
copyright or other intellectual property right. Intel products are not intended for use in medical, life saving, or life sustaining
applications. Intel may make changes to specifications and product descriptions at any time, without notice. The Intel products
described herein may contain design defects or errors known as errata which may cause the product to deviate from published
specifications. Current characterized errata are available on request.
Products Affected
This is a list of suspect systems only. A suspect system will require further investigation to determine if it is affected by
the issue covered in this Technical Advisory.
Product Code MM# Serial Number Range Backplane
PBA#
SR1625URR 905664 BZDT006xxxxx – BZDT007xxxxx E27104-403
SR1625URSAS 900987 BZDT006xxxxx E27104-403
SR1625URSASR 905665 BZDT006xxxxx – BZDT007xxxxx E27104-403
SR2600URBRP 901093 BZDT002xxxxx – BZDT006xxxxx E32704-203
SR2600URBRPR 905666 BZDT006xxxxx E32704-203
SR2600URLX 900988 BZDT002xxxxx – BZDT006xxxxx
BZPR006xxxxx
E32704-203
SR2600URLXR 905667 BZDT006xxxxx
BZPR007xxxxx
E32704-203
SR2600URSATAR 905671 BZDT007xxxxx E32704-203
SR2600URSAS 903736 BZDT003xxxxx – BZDT006xxxxx E32704-203
SR2625URLXR 905669 BZDT005xxxxx – BZDT007xxxxx
BZPR006xxxxx – BZPR007xxxxx
E26398-303
SR2625URBRPR 905668 BZDT007xxxxx – BZDT012xxxxx
BZPR005xxxxx – BZPR007xxxxx
E26398-303
SR2625URSASR 905670 BZDT006xxxxx E26398-303
Description
In the SR1625, SR2600, and SR2625 systems, the SATA Optical drive plugs directly into the backplane using a
standard 13-pin SATA connector. This SATA channel is routed to a GL830 USB to SATA converter, located on the
backplane. The optical drive is seen as a USB device in the system.