Dual Intel Xeon Processor Voltage Regulator Down (VRD) Design Guidelines
Dual Intel
®
 Xeon™ Processor Voltage Regulator Down (VRD) Guidelines 
14 
Table 3 – Low Voltage Intel
®
 Xeon ™ Processor Voltage Deviations from VID 
VRD 
Icc 
UP Low 
Voltage Intel 
Xeon 
Processor Vcc 
DP Low 
Voltage Intel 
Xeon 
Processor Vcc 
 Max Min Max Min 
0 1.300 1.274 1.300 1.274 
5 1.295 1.269 1.298 1.272 
10 1.291 1.265 1.295 1.269 
15 1.286 1.260 1.293 1.267 
20 1.281 1.255 1.291 1.265 
25 1.276 1.250 1.288 1.262 
30 1.272 1.246 1.286 1.260 
35 1.267 1.241 1.283 1.257 
40 1.262 1.236 1.281 1.255 
45 1.257 1.231 1.279 1.253 
50    1.276 1.250 
55    1.274 1.248 
60    1.272 1.246 
65    1.269 1.243 
70    1.267 1.241 
75    1.264 1.238 
80    1.262 1.236 
85    1.260 1.234 
2.1.6  Turn-on Response Time     
The output voltage should reach its specified range within 50 msec of the input power’s reaching 
its minimum voltage. 
2.1.7  Overshoot at Turn-On or Turn-Off     
Overshoot upon the application or removal of the input voltage must be less than 2% above the 
nominal output voltage set by the Voltage Identification (VID) code. No negative voltage below 
−0.1V may be present at the output at any time. 