User's Manual

Intelibs, Inc. Proprietary and Confidential Page 18
18
3 Installation
3.1 Installation Requirements
Before and during installation, the following should be carefully verified in order to avoid any
problem:
Faulty Cabling/Connectors: Fiber cable and connectors must be verified prior to plugging
into the RHU
Dirty Connectors and ports
Faulty Radio Hub Unit (RHU) components
RF source equipment issue
External RF Interface problem such as antenna port
The following guidelines are required when the RHU is installed on the 19” rack of Headend room:
Bandwidth
Any 30MHz BW in each band
Channel filter BW
Combination of 1.25MHz BW
@ Except 850MHz band
Input level
DL
-60 ~ -30dBm/total
@ each band total input level
UL
0dBm/total max.
@ from SRU/BEU
Output level
DL
0dBm/total
@ optic input level
UL
20dBm/total
@ Link ANT output level
RF Gain
DL
45dB typ. by 1dB step
@ 10 ~ 40dB gain control
UL
45dB typ. by 1dB step
@ 10 ~ 40dB gain control
Gain Flatness
2dBp-p
@ Any 30MHz BW
Inband gain difference
3dB max.
@ all band width of each band
Noise Figure
DL
Less than 6dB
@ 40dB gain of DL
Noise level
UL
Less than -88dBm/Hz
@ RHU UL 45dB gain
Optical wavelength
DL 1310nm / UL 1550nm
Available Optic Loss
5dBo max.
@ RHU RU
Out of band rejection
More than 40dBc
More than 100dBc
More than 100dBc
@ ±1.25MHz from band edge
@ out of band
@ DL/UL Isolation
RF port VSWR
1.5: 1 max.
@ All of RF Port
Frequency Stability
±0.02 ppm
System Delay
3.0usec max.
Isolation Margin detect
0dB ~ 20dB Margin
Fiber Connector
LC/UPC
RF connector
ANT Port: 4.3-10 Female
Power consumption
100W max. for 4-Band RHU
80W max. for 2-Band &
@ 20dBm output of UL HPA
DC power
PoE/AC120V
AC120V only
@ 2-Band Mobile and 2-GPS
@ 4-Band Mobile