FLX-HI4A Specific Commands
The input number values are dependent upon which slot the FLX-HI4A is inserted. If the input
card is in the first input card slot, the input number values range from 1 through 4. If the input
card is in the second input card slot, the input number values range from 5 through 8. [X] is the
input number value.
Description
Command
Response
Set input xx to analog audio input embedding
AUDIOxx:0.
AUDIOxxI0.<CR><LF>
Set input xx to digital audio (use HDMI audio)
AUDIOxx:1.
AUDIOxxI1.<CR><LF>
Examples:
AUDIO07:0.
Use analog audio for input 7.