- IMS MDrive17 Motion Control Operating Instructions

51
MNEMONIC FUNCTION TYPE
MS Microstep Resolution Motion Variable
DESCRIPTION
The MS variable controls the microstep resolution of the MDrive Motion Control. There are 14 parameters that can be used with
this variable, 8 binary and 6 decimal. The table below illustrates the parameter settings and their associated resolutions for the 1.8°
stepping motor used with the MDrive Motion Control.
The MS parameters given in the table below are the only valid parameters that will be accepted by the MDrive.
USAGE DEFAULT
MS=<parameter> 256
EXAMPLE:
MS=4 ‘Set Microstep Resolution to 4 Microsteps/Step (400 Steps/Rev)
MS=50 ‘Set Microstep Resolution to 50 Microsteps/Step (10000 Steps/Rev)
PR MS ‘Print the MS setting to the terminal
)SM(sgnitteSnoituloseRpetsorciM
)petS/spetsorciM(=SM veR/spetS
sgnitteSnoituloseRpetsorciMyraniB
2004
4 008
8006,1
61 002,3
23004,6
46 008,21
821006,52
652 002,15
sgnitteSnoituloseRpetsorciMlamiceD
5000,1
01 000,2
52000,5
05 000,01
521000,52
052 000,05
Table 2.6: Microstep Resolution Settings