User manual
- 105 -
Appendix H: Reinstating the Factory Default Settings   
This information details how to set the default settings for the Pro Series Network Camera. In 
certain circumstances, it may be necessary to restart or reinstate the factory default settings for 
your camera. This is done by pressing the Reset button or by using HyperTerminal settings.   
Pressing the Reset Button   
1. Using a paper clip or any sharp pin, press the Reset button on the back of the camera.   
2. Switch off the camera by disconnecting the power cable.   
3. While pressing the Reset button, reconnect the power supply cable. Keep the Reset button   
    pressed until the green Operating Status LED blinks three times (this may take 10 to 15   
    seconds). Release the Reset button.   
Using HyperTerminal   
1. Run "HyperTerminal" (see 4.3.1).   
2. Supply power to the camera.   
3. After a few moments, the countdown begins with the prompt "Press any key to stop auto 
booting within 3 seconds..." Press any key to display the screen below.   
When you enter "Set," the administrator ID and password reinstate as factory default "admin."   
NOTE: 
Reinstating the original default settings will cause all parameters (including IP address) 
to be reset.   
Factory default settings   
Administrator ID: admin   
Administrator password: admin   
Guest ID: guest   
Guest password: guest   
IP address: 192.168.1.221   
Subnet mask address: 255.255.255.0   
Gateway address: 192.168.1.1   
Server IP address: 192.168.1.5   