Operation Manual System Remote MIC Station/ 12Key MIC Station Keypad RM-6024/RM-6012KP
SYSTEM REMOTE MIC STATION/12KEY MIC STATION KEYPAD Welcome A personal welcome to you from the management and employees of Inter-M All of the co-workers here at Inter-M are dedicated to providing excellent products with inherently good value, and we are delighted you have purchased one of our products. We sincerely trust this product will provide years of satisfactory service, but if anything is not to your complete satisfaction, we will endeavor to make things right.
SYSTEM REMOTE MIC STATION/12KEY MIC STATION KEYPAD Contents Unpacking .......................................................................................................................................2 Installation Environment....................................................................................................................................2 Important Safety Instructions.............................................................................................................
SYSTEM REMOTE MIC STATION/12KEY MIC STATION KEYPAD Unpacking Although your RM-6024 is neither complicated nor difficult to operate, we recommend you take a few minutes to read this brief manual and familiarize yourself with the important information regarding product features, setup and operation. As with most electronic devices, we strongly recommend you to retain the original packaging.
SYSTEM REMOTE MIC STATION/12KEY MIC STATION KEYPAD Features - ZONE MACRO FUNCTION Zone one Macro Function exists for each button in the Inter-M PC Windows program allowing multiple zones to be bundled into one single button. Maximum 160 zones per button. - EXPANSION KEYPAD (RM-6012KP) If an Expansion Keypad (RM-6012KP) is added, a total of 48 macro buttons can be used. (Up to 2 Expansion Keypads can be connected) - CHIME FUNCTION Serves as the notification sound to announce a remote MIC broadcast.
SYSTEM REMOTE MIC STATION/12KEY MIC STATION KEYPAD Equipment Setting and Checking 1. Address Switch Setting 1) Set the equipment number utilizing the rear panel DIP switch. - If the equipment number is not set-up or is incorrect, all Zone Indicator LEDs will blink. - If the number is already in-use, the FAULT LED will blink. Please check the equipment number set-up status.
SYSTEM REMOTE MIC STATION/12KEY MIC STATION KEYPAD 4) The table below shows the set-up method, and if DATA number is added to switch turned ON, it will be the equipment number. Pin No. Data Address 1 2 3 4 5 15 16 1 1 ON ON 2 2 4 8 5 16 ON ON ON ON ON ON 3 4 ON ON ON ON (Ex: When No. 1 and 3 is ON, add 1 and 4 which is actual corresponding number, and then equipment number will be 5.
SYSTEM REMOTE MIC STATION/12KEY MIC STATION KEYPAD 2. Disassemble and Assemble of Side Pad (Required when expanding the keypad.) ※Dissemble the side pad 1. Unfasten the 3 screws in bottom. 2. Slightly pull up ① and ②, side pad will be separated from the main body. 3. Pull out to ③, and side pad and main body will separate. ῡ ΰ ῢ ῢ D C B A ※Assemble the side pad 1. Insert ① (lock) into ②. 2. Pull the side pad downward. 3. Fasten screws in bottom, and then complete the assembly. ῡ LOCK A B 3.
SYSTEM REMOTE MIC STATION/12KEY MIC STATION KEYPAD Front Panel 1 2 5 3 4 6 7 8 9 1. ALL BUTTON Used when broadcasting to all zones. 2. MIC Condenser MIC. 3. OUTPUT LEVEL LED Display the MIC output level. 4. POWER/FAULT/BUSY LED - POWER LED (GREEN) : displays the power input status. - FAULT LED (RED) : will be ON if communication error occurs. - BUSY LED (RED) : will blink if there is any higher priority broadcast.
SYSTEM REMOTE MIC STATION/12KEY MIC STATION KEYPAD 5. CHIME BUTTON CHIME button is operated only in TALK mode. 6. TALK ON/OFF BUTTON Select the broadcasting zone(s), then push and release the TALK button to broadcast. After finishing the broadcast, push the TALK button again to end the transmission. 7. ZONE DISPLAY LED AND LABEL - Push the zone selecting button, and then corresponding LED (GREEN) will be ON. - Zone information can be labeled and inserted. 8.
SYSTEM REMOTE MIC STATION/12KEY MIC STATION KEYPAD Rear Panel 1 2 3 4 5 1. DC INPUT TERMINAL - Power input terminal. Check polarity before connecting DC 24V. - When connecting to PD (Power Distributor), connect to unswitched terminal. 2. ADDRESS SWITCH Sets up the equipment number. 3. DATA & AUDIO TERMINAL (RJ-45) Transmits the communication DATA and AUDIO signal. PIN NO.
SYSTEM REMOTE MIC STATION/12KEY MIC STATION KEYPAD 4. MIC/AUX/CHIME VOLUME - CHIME Volume : adjust the CHIME output level. - MIC Volume : adjust the MIC volume. - AUX Volume : adjust the AUX volume. 5. AUX INPUT TERMINAL Used when broadcasting through the RM-6024 with an external sound source. In this case, MIC and AUX sound sources will be mixed and transmitted.
SYSTEM REMOTE MIC STATION/12KEY MIC STATION KEYPAD Applications EP-6216 MATRIX PRE IN REMOTE MIC MIC SW AUTO. ANN EXT REMOTE IN 2 REMOTE IN 1 TIMER IN AUTO ANN IN PRE OUT SIREN/VOLUME INT 12 0 DC OUT 24V CONTROL OUT (TO AUTO ANN) ECS-6216P RM1 RM2 INPUT 1 FIRE SENSOR 2 3 4 5 6 7 8 PD TIMER LINK IN INPUT LINK OUT RS 232 UPGRADE SOURCE 1 SOURCE 2 TERM.
SYSTEM REMOTE MIC STATION/12KEY MIC STATION KEYPAD 12 RM-6024/RM-6012KP RS-422 RS-422 Block Diagram
SYSTEM REMOTE MIC STATION/12KEY MIC STATION KEYPAD Specifications RM-6024 Channel 24CH Communication Protocol RS-422(Maximum 1km/3,280 feet) Audio MIC INPUT SENSTIVITY -60dB THD+N AUX Less than 0.5% FREQUENCY RESPONSE 120Hz ~ 20kHz S/N Better than 50dB INPUT SENSTIVITY -10dB THD+N Less than 0.5% FREQUENCY RESPONSE 120Hz ~ 20kHz S/N Better than 60dB Operation Temperature -10°C ~ +40°C/14°F ~ 104°F Power Source DC 24V Weight (Set) 1.2kg/2.
SYSTEM REMOTE MIC STATION/12KEY MIC STATION KEYPAD ※ DIMENSIONS -RM-6024 456 65 199 -RM-6012KP 137.
SYSTEM REMOTE MIC STATION/12KEY MIC STATION KEYPAD Service Procedures Take steps to insure the problem is not related to operator error or other products within the system. Information provided in the troubleshooting portion of this manual may help with this process. Once it is certain that the problem is related to the product contact your warranty provider as described in the warranty section of this manual. Schematic A Schematic is available by contacting your warranty provider.
NOTE 12 RM-6024/RM-6012KP
RM-6024/RM-6012KP 13
Inter-M, Ltd. (Korea) began operations in 1983. Since then, Inter-M has grown to become one of the largest manufacturers of professional audio and commercial sound electronics equipment in the world. Inter-M has gained worldwide recognition for its own branded products, as well as private label manufacturing of electronics sold under other names (OEM).