Product Data Sheet / Brochure

2–2.4kW Single-Phase ATS/Switched PDU,
200–240V Outlets (10 C13), 2 C14 Inlets, 3.6 m
Cords, 1U Rack-Mount, TAA
MODEL NUMBER: PDUMH15HVATNET
Description
The PDUMH15HVATNET 2–2.4kW Single-Phase 200–240V ATS/Switched PDU provides remote power
monitoring and enables redundant power for network devices with non-redundant power supply configurations.
Ideal for data centers and server rooms, it mounts in 1U of space in EIA-standard 19-inch racks and features
eight switched and two unswitched C13 outlets.
Dual 3.6-meter input cords with IEC-320 C14 plugs connect to separate primary and secondary single-phase power sources in a nominal voltage range from
200–240V. Plug lock inserts prevent cords from accidental disconnection. The PDUMH15HVATNET constantly evaluates the power quality of both input
sources. Dynamic solid-state(TRIAC) automatic transfer switching allows the PDU to switch to the secondary source within 2–5 milliseconds should the primary
source fail or become unstable to ensure your connected equipment operates without interruption.
Built-in Ethernet network interface allows remote access to the PDU for power monitoring, configuration, control and notifications via web browser, SSH, telnet
or SNMP. Supports user-programmable startup of outlets in any order or interval to ensure network items are turned on in the proper sequence and reliably
discovered. Digital ammeter monitors total output current. LEDs display outlet on/off status and input power status on primary and secondary inputs.
Connecting the optional ENVIROSENSE module(sold separately) lets you remotely monitor temperature and humidity.
Features
Primary and Secondary Inputs for Power Redundancy
Provides remote power monitoring and enables redundant power for network devices with non-redundant power supply configurations
Dual 3.6 m input cords with IEC-320 C14 plugs connect to separate primary and secondary single-phase power sources
8 switched and 2 unswitched C13 outlets
Automatic Transfer Switching
Dynamic solid-state(TRIAC) automatic transfer switching
Switches to secondary power source if primary source fails or becomes unstable
Highlights
Single-phase IEC-320 C14 input
8 switched and 2 unswitched
C13 outlets
Automatic transfer switching
within 2–5 ms
Ethernet network interface for
remote outlet control
Digital load meter for real-time
output current monitoring
Package Includes
PDUMH15HVATNET
TAA-Compliant 2–2.4kW
Single-Phase ATS/Switched PDU
(10) C14 plug lock inserts
(2) C13 to C14 power cords, 3.6
m(11.8 ft.)
SNMPWEBCARD configuration
cable
(2) Mounting brackets, horizontal
(2) Mounting brackets, vertical
(6) Screws
Owner’s manual