Technical Manual for Master Terminals of the Series IF 152x
Page 22
Connection 24 V Mains Power Cable
Connect 24 V mains power cable (recommended cable type NYM 3x 1.5 mm) to terminal strip Kl. 1 as
follows:
+ 24V DC/ AC to terminal 1
- 24V DC/ AC to terminal 2
Ground
Connection Ethernet Network Cable (10 Base T)
Connect Ethernet twisted pair cable to Ethernet connector RJ 45.
1
2
3
4
5
6
7
Br.1 A
Br.1 B
J 3
8
connection
24V DC/ AC
12
+ -
J 6
J 12J 21
J 20
LED
LINK
LED
RX
5
3
1a
1
2
4
1 Connector board 3 Strain relief
1a Fasten 24V main power cable KL.1 4 24 V mains power cable
2 Ethernet board 5 RJ 45 connector for Ethernet patch cable
# Caution: Secure all cables with a strain relief.