Installation Instructions

Page
3
Assembly
1b
1a
1
B
80.3/ 3.16
68.8/ 2.7
40.8/ 1.6
42.4/ 1.66.
20.4/ 0.8
1b
A
1a
C
1,100/
43.31
1
2
3
LED GN
LED RD
SHIELD
D 2/ CPS
D 1/ DATA1
D 0/ DATA0
BUZ
GND
+V DC
Wiring:
green
pink
black
grey
white
brown
yellow
blue
red
A Assembly B Connection C Drilling plan
1 Housing with board 1 Housing with MPU
1a Chamfering 1a Fastening bores
1b Connecting cable 1b 7 mm knockout for cable (1b)
2 Cover
3 Countersunk bolts
The following points must be considered when the reader is installed:
1. The potted electronics permits an installation not only in a dry but also in a wet
environment.
2. The minimum distance to other systems equipped with proximity readers is limited to
0.3 meters/11.8”.
3. If mounted on metal, a minimal impact on the read range performance must be taken
into account.
4. Only use countersunk bolts which are flush with the chamfering (Figure A, 1a) for
fastening the housing.
5. When having completed the function test, put on the cover, push it to the back until it
locks in place.
Connection
Connect the connecting cable to the terminal strip designated for this purpose in the door
manager. The colors of the conductors as well as the relevant signals are shown in Figure B.
How to Correctly Present the Identification Medium
In order to permit a correct data capture, the identification medium must be presented within
the specified read range and in parallel to the proximity reader (see figure below).
A
1
2
A Card presentation
1 Card 2 LED: display