INSTALLATION OF POWER BOX
Insert power box to rail under
panel. No tools required.
Move power box under
panel/raceway and align notches
on top of power box(es) with
openings on aluminum plate on
bottom of raceway. Push up to
connect the two parts and move left
or right approximately 1 inch until
power box feels snug.
Single 36" Panel
Power Box
Push cable into power box until cable
is fully inserted. This will be evident
when the power box latch is
fully engaged and flat against
the cable end. Failure to
ensure the cable is
fully inserted may
result in power
interruption.
10
Extended/Corner
Cable
Extended/
Corner
Cable
Extended/Corner
Cable
1
2
L
CABLE INSTALLATION
Pass Thru Application
Cables run between panels as needed
Panel 1 Panel 2 Panel 3
When connecting around a 90° corner or across a 3 way
or 4 way, discard the panel to panel cable and use the
extended/corner cable.
36” PANEL
48” & 60” PANEL
Double 48" Panel
Power Box
Double 60" Panel
Power Box
Fire Risk. Connection to the power source, by a
licensed electrician, and quantity of receptacles
used for a given circuit, must be in compliance
with all national and local electrical codes. Failure
to observe this warning could result in a fire.
Risk of electrical shock. Be sure in-feed power
is disconnected to prevent personal injury.
No more than 16 simplex receptacles may be
supplied by one 15 AMP circuit.
No more than 20 simplex receptacles may be
supplied by one 20 AMP circuit.
Electrical connections between panels must
be disconnected prior to removal of a
mechanical connection.