User Manual
UL Specifications
Part Loop Electrical Gap
Number Type Configuration Distance
*
1065W Closed N.O. 2"
1070 Open or Closed SPDT
1
/
2
"
1075 Closed N.O.
1
/
2
"
1075W Closed N.O. 1
1
/
4
"
*
Gap Specifications are nominal and may vary
±
20%. Gap Specifications are for switch to make.
Break distance is approximately 1.1 to 1.5 times make.
**
European Union Specifications: 48 V AC/DC max, 0.5 Amp
**
FORM A (1065W, 1075, 1075W) FORM C (1070)
Voltage: 100 V AC/DC max Voltage: 30 V AC/DC max
Current: 0.5 A max Current: 0.25 A max
Power: 7.5 W max Power: 3.0 W max
WARNING: Each electrical rating is an individual maximum and cannot be exceeded!
C-UL Specifications
All Contacts: 30 VDC, 50 mA max Gap Specifications:*
See UL Gap Specification
1075 Series
3
/8" Diameter Press-Fit with Wire Leads
Installation Instructions
1. Drill appropriate diameter and depth holes for contact and magnet (
3
/8" x 1
1
/3" for contacts
and
3
/8" x 1
1
/2" for 1065W magnets,
3
/8" x 1
1
/3" for 1070, 1075, and 1075W magnets).
2. Connect contact leads to security system loop and test for continuity.
3. Lightly coat the contact and magnet with RTV mounting compound (Part Number 1905)
and insert into respective holes.
.36"
0.91cm
Magnet
Part No. 1924
(Included)
.44"
1.12cm
1.30"
3.30 cm
1.30"
3.30cm
.03"
0.08cm
PK-0985 Rev H 07/02
www.GE-InterlogixSecurity.com 2266 Second Street North
North St. Paul, MN 55109
Phone: 651-777-2690
USA & Canada: 800-777-5485
Technical Service: 800-777-2624
12345 SW Leveton Drive
Tualatin, OR 97062
Phone: 503-692-4052
USA & Canada: 800-547-2556
Technical Service: 800-648-7424
Faxback: 800-483-2495
GE Interlogix
Made in Taiwan