Instruction Manual
As shown in Figure 7 below, pets are free to roam below the
mounting height of the unit without causing alarms.
Regulatory information
Listings UL 639
FCC compliance
(Class A & B)
This device complies with Part 15 of the FCC
rules. Operation is
subject to the following two conditions:
1 This device may not cause harmful
interference.
2 This device must accept any interference
received, including interference that may cause
undesired operation.
Certification
Figure 7: Pet alley
3 ft.
(0.9m)
Product ordering
Product Description
AP750-ID An addressable, passive infrared motion sensor for use
with the NX-2192 PinPoint Bus Interface.
Specifications
Contact information
Housing material Flame retardant ABS
Operating voltage 8 to 27V (as supplied by NX-2192)
Current draw 250μA typical average 3 mA with LED
momentarily on
Transmit condition Alarm, tamper
Detection range 50 feet (15.2m)
Mounting height 6 to 10 feet (1.8 to 3m)
Number of curtains 7
Operating temperature 32 to 131° F (0 to 55° C)
Relative humidity 10 to 90% non-condensing
Maximum line length 10,000 feet (3km)
Dimensions:
Width
Depth
Height
2.9 inch (7.4cm)
2.2 inch (5.6cm)
5.1 inch (12.9cm)
Color White
www.utcfireandsecurity.com or www.interlogix.com
For customer support, see www.interlogix.com/customer-
support
Copyright © 2011 UTC Fire & Security. All rights reserved.
4 AP750-ID Installation Instructions