Installation Manual Instruction Manual

Chapter 4: Testing and troubleshooting
96 Concord 4 Installation Manual
Testing the system
Before testing, we recommend that you close the panel cabinet door and the
covers on all modules (mounted outside the cabinet.) The testing environment
should match the system working environment.
You should test the system after installation or service and after adding or
removing devices from the system. See Cellular backup communication on
page 104 if you do not achieve correct test results.
Testing the system includes:
Basic system commands below
Zones/sensorson page 97
Phone communication on page 98
Central station/pager communicationon page 99
Outputs and sirenson page 100
Light control on page 101
Energy saver module (ESM)on page 101
Fixed display LCD touchpad chime and trouble beep tones on page 102
Audio verification module communication on page 103
Cellular backup communicationon page 104
Basic system commands
Table 14 below describes basic touchpad operating commands. For complete
details on system operation, including user programming, refer to the Concord 4
User Manual.
Table 14: Basic touchpad commands
Command
System response
* (STATUS)
Indicates current system status
*, *
Indicates AC power, battery, and current system status
1, code
Disarms system to OFF
2, code
Arms system to STAY
2 (quick arm on)
Arms system to STAY
3 (quick arm on)
Arms system to AWAY
2 or 3, code, 4
or
2 or 3, 4
Arm systemno delay (no exit or entry delay)
5, 2 or 3, code
or
5, 2 or 3
Arms system silently (no arming status beeps