Installation Manual Instruction Manual

Chapter 4: Testing and troubleshooting
100 Concord 4 Installation Manual
Codes
System event
333
System armed to AWAY
555
Phone/sensor test
888
System trouble condition
999
System in alarm
Table 16 below describes pager sensor/zone number and user number report
codes.
Table 16: Pager sensor/zone code and numbers
Code
Sensor/zone or user number
000
System event not caused by a zone or user
001096
Sensor/zone numbers 1 to 96
600829
Regular user codes 0 to 229 used
830-837
Partition master code used
838-845
Partition duress code used
846
System master code used
847
Installer code used
848
Dealer code used
850
Quick arm used
851
Keyswitch sensor used
852
System armed Itself (during service or power-up)
Outputs and sirens
You should test all outputs (onboard and SnapCard) to verify configuration
programming.
Note: Be sure to contact the central monitoring station before activating outputs
that trigger from an alarm condition.
To test outputs:
1. Contact the central monitoring station to inform them you are testing the
system.
2. Verify that all wiring at the panel and output devices is correct.
3. Activate the appropriate device to trigger each output as programmed.