Installation Manual Instruction Manual

Chapter 4: Testing and troubleshooting
102 Concord 4 Installation Manual
To test the energy saver module:
1. Press *, * to display the system status, ENERGY SAVER OFF, and the present
TEMPERATURE nn°. The temperature displayed (and/or announced) should
match the house thermostat. If the temperatures do not match, refer to
Accessory modules - bus device settingson page 73.
Note: There is a 5-minute delay after the energy saver module returns control
to the furnace/AC before it will override the furnace/AC again.
2. Press 7, 2 to turn on the ESM. The display shows ENERGY SAVER ON and
the ESM relay will click once.
3. Press 7, 2 again to turn the ESM off. The display shows ENERGY SAVER
OFF.
Fixed display LCD touchpad chime and trouble beep
tones
You can adjust the frequency (pitch) of chime and trouble beep tones from a
fixed display touchpad to a more desirable or distinct tone, or to compensate for
hearing impaired persons.
To change status tone pitch:
1. Press and hold the * and 0 buttons together until you hear a steady tone, then
release the buttons.
Note: Chime and trouble beep tones sound using the default frequency
during, or within 15 seconds of, any button activity at that specific touchpad.
2. Press and hold 1 to lower the pitch or press and hold 2 to raise the pitch.
3. Release the button when the desired pitch is heard.
After about 15 seconds of no touchpad activity, the steady tone stops
sounding.
Touchpad display contrast
You can adjust touchpad displays for easier viewing to help compensate for
lighting conditions in the touchpad location. The contrast adjustment lightens or
darkens the text. (Vacuum fluorescent displays do not have a contrast
adjustment.)
To adjust display contrast:
1. Enter configuration mode by pressing the D and 6 buttons together for at least
2 seconds. The display shows DA nnn.