Chapter 4: Testing and troubleshooting
104 Concord 4 Installation Manual
4. The central station operator waits for the alarm to be reported and initiates an
audio session.
5. Walk through the vicinity of the AVM while speaking at a normal conversation
level.
6. Have the operator speak to you.
7. When testing is complete, the operator will end the session.
Cellular backup communication
To check the cellular communication between the panel and the central
monitoring station:
1. Contact the central monitoring station to inform them that you are testing the
system.
2. Install and activate the SuperBus 2000 cellular backup module.
3. Verify or change the following CS phone panel option settings shown in
Cellular backup communicationabove.
Note: If the current settings do not match the test settings, record the current
settings (Table 17 on page 101), so that they can be restored when this test is
complete.
4. Disconnect the phone line by unplugging the DB-8 cord from the RL 31X jack.
5. Initiate a phone test (8, system master code, 2).
6. The phone test attempt should fail via the phone line within 5 minutes. The
panel will emit a long low tone (and speak phone failure 1” if so equipped).
7. Wait for the phone test to succeed via the cell backup. The panel should emit
a short high tone (and speak phone test okayif so equipped).
8. Verify the CS report.
9. If success does not occur, verify that the signal strength (RSSI) shown on the
cellular backup module is acceptable and repeat the process.
Table 18: Cellular backup communication
CS phone 1 option
Test setting
Previous setting
Phone number
Central station phone number
High level reports
On
Backup
Off*
Cellular backup
On
*Can be set to On if no CS phone 2 phone number is programmed.