Installation Manual Instruction Manual

Chapter 4: Testing and troubleshooting
Concord 4 Installation Manual 111
Touchpad is not connected to panel bus terminals or is wired incorrectly.
Check and correct wiring.
Check that touchpad is learned into panel memory.
Display is blank.
Check that panel is powered up.
Check for touchpad power and/or incorrect bus wiring, opens, or shorts.
Check the touchpad brightness setting. (See the user-programming Options
menu on page 108.)
Touchpad buttons dont beep when pressed.
Check for touchpad power and/or incorrect bus wiring, opens, or shorts.
Check that key beeps option is set to on. (See the Accessory modules - bus
device settings on page 93.)
Speaker issues
Speakers don’t sound alarms.
Speaker output has shut down because panel detected terminal 7 or 8 is
shorted to ground. Disconnect panel AC and battery backup power. Locate
short and correct. Apply panel AC and backup battery power and retest.
Alarm is in partition 2 to 6 and speaker is connected to panel terminals 7 and
8, which activate only for partition 1 alarms.
Siren issues
Piezo sirens connected to SnapCard, or onboard (panel) outputs 1 and/or 2
don’t produce any alarm sounds.
Check for incorrect wiring between siren and panel, and correct where
necessary.
Output has not been configured (set up) to activate sirens. Enter program
mode and configure output. (See Accessory modules - bus device settings on
page 93.)
Check for correct output partition assignment.
Check that your wires are connected to the appropriate terminals:
Output 1 (exterior) uses terminals 9 (positive) and 13 (ground).
Output 2 (interior, follows status beeps) uses terminals 11 (positive) and 10
(ground).