Installation Manual Instruction Manual

Chapter 2: Installation
Concord 4 Installation Manual 19
Figure 10: Connecting hardwired interior speakers
SPKR SPKR SPKR SPKR
Not used
Not used
7 8 7 8
Exterior/interior piezo sirens
Onboard output 1 (OUT 1terminal 9) is a 9 to 14 VDC switched, programmable
output that can handle a maximum of 1,000 mA current. The default setting
(01614) activates the output 30 seconds after a police or fire alarm condition
occurs. This allows you to connect a piezo siren without changing the output
configuration number in programming. This output is typically used for exterior
siren applications. Connect multiple piezo sirens in parallel. (For more
information on output configuration numbers, see “Onboard options menuon
page 78.)
Note: For 24-hour backup, external power drain is limited to 90 mA (during
normal standby condition), using a 4.5 or 5.0 Ah battery, or 190 mA continuous
using a 7.0 Ah battery.
Piezo dynamic exterior siren (13-950)
Connect the siren to panel as shown in Figure 11 on page 20.