Chapter 2: Installation
Concord 4 Installation Manual 25
of the cabinet using an optional plastic housing (part no. 60-800). Refer to the
documentation that comes with each module, for complete mounting instructions.
The module requires panel power and bus connections, phone line connection
through panel terminals and DB- 8 cord (from an RJ-31X jack), and speaker
connection through panel terminals. Connect the module to the panel power and
bus terminals as shown in Figure 19 below.
For partition 1, connect the phone line to the module through the panel terminals
and DB-8 cord (from an RJ-31X jack) as shown in Figure 19 below. For partitions
2 to 6 phone connections, see the documentation that comes with each module.
Figure 19: Wiring the phone interface/voice module
Note: To prevent status voice messages from being broadcast outside, do not
connect exterior speakers to phone interface/voice module terminals 6 and 7.
Wiring for status voice messages only
Connect an interior speaker to the phone interface/voice module terminals as
shown in Figure 20 on page 26. When connected as shown, the speaker only
produces status voice messages. In an alarm, the speaker announces voice
status messages.
Wiring for status and alarm messages
Make all of the connections shown in Figure 20 on page 26 only if the phone
interface/voice module is being installed in partition 1 and alarm sounds are
desired. In an alarm, the speaker alternates between alarm siren tones and voice
status messages.