Installation Manual Instruction Manual

Chapter 2: Installation
28 Concord 4 Installation Manual
SuperBus 2000 wireless cellular gateway
Connect the SuperBus 2000 wireless cellular gateway module to the SuperBus
2000 terminals as shown in Figure 24 below.
Caution: Since the SuperBus 2000 wireless cellular gateway module draws
more than 1 amp, it must be powered by the SuperBus 2000 2-amp power
supply and not the panel.
Figure 24: Connecting a wireless cellular gateway module
1 2 3 4 5
6
24 VAC
24 VAC
+12 V
BUS A
BUS B
GND
GND
GND
+12 V OUT
ZONE
SuperBus 2000 2-amp
power supply terminals
Phones
The panel cannot be used on a digital or PBX phone line. These systems are
designed for digital type devices only, operating anywhere from 5 VDC and up.
The panel uses an analog modem and does not have a digital converter,
adapter, or interface to operate through such systems.
Note: Some telephones are polatity-sensitive. Green and red wires may need to
be reversed.
RJ31X phone jack
Use the following guidelines when installing an RJ31X phone jack for system
control by phone and central station monitoring:
Locate the RJ31X jack (CA-38A in Canada) no further than 5 feet from the
panel.
The panel must be connected to a standard analog (loop-start) phone line,
that provides 48 VDC (on-hook or idle).