Installation Manual Instruction Manual

Chapter 2: Installation
Concord 4 Installation Manual 31
Backup battery
Use the 60-681 (12 VDC, 4.5 or 5 Ah) or 60-680 (12 VDC, 7Ah) backup battery.
The battery is automatically tested every 24 hours. Without AC power, the panel
will shut down if the battery voltage falls below 10.2 VDC. Replace the battery
when necessary with the same battery model.
Note: The backup battery leads must be routed along the side of the enclosure
and secured with a cable tie.
Figure 26: Connecting panel power transformer and backup battery
Black (negative)
Red (positive)
Battery
1 2
16.5 VAC
Power up
To power up the panel:
1. Connect the red and black backup battery leads (included with panel) to the
lugs on the panel.
2. Connect the other ends of the backup battery leads to the battery terminals.
3. Plug the transformer into an outlet that is not controlled by a switch.
4. Alphanumeric touchpads display ************, then SCANNING BUS DEVICES,
and finally a date and time display.
Note: If alphanumeric touchpads dont display anything, immediately unplug
the transformer and disconnect the backup battery.
5. To permanently mount the transformer, unplug it and remove the existing
screw securing the AC outlet cover
WARNING: Use extreme caution when securing the transformer to a metal
outlet cover. You could receive a serious shock if a metal outlet cover drops