Installation Manual Instruction Manual

Chapter 3: Programming
38 Concord 4 Installation Manual
System
programming
Use this setting to access the tier 2 programming menus. (See Tier 2
programming menus on page 40.)
Demo kit mode
Default = Off
This setting determines whether you use your panel for a standard
installation (off) or as a demo kit (on). When the demo kit option is on, only
sensors learned into groups 01 and 03, duress code use, and phone test
(8, system master code, 2) are reported. Turning on this feature and doing
a memory clear changes the following settings:
Partition 1 master code = 1000
Partition 2 master code = 2000
User code 00 = 1001 (partition 1 code you may use to jump to partition
2)
User code 01 = 1002 (partition 1 code you may use to bypass sensors)
User code 02 = 2001 (partition 2 code you may use for remote or offsite
access)
User code 03 = 2002 (partition 2 code you may use to perform system
tests)
User code 04 = 1122 (partition 1 code you may use to jump to partition
2, for remote or offsite access, and system tests)
User code 05 = 2233 (partition 2 code you may use to jump to partition
1, for remote or offsite access, bypassing sensors, and system tests)
Partition 1 house code = 255 (P)
Partition 2 house code = 254 (O)
Zone 1 (hardwired input 1) = Group 10, front door
Zone 2 (hardwired input 2) = Group 13, bedroom window
Zone 3 (hardwired input 3) = Group 17, living room motion sensor
Zone 4 (hardwired input 4) = Group 1, panic
Zone 5 (wireless keyfob, ID F00201) = Group 01, (no text)
Zone 6 (wireless DWS, ID A00206) = Group 13, kitchen window
Com failure = off, Demo kit = on
AVM code = 1212
Entry delay = 8 seconds
Exit delay = 8 seconds
Extended delay = 1 minute
Siren timeout = 2 minutes
To turn demo kit mode off or on:
1. With the display showing DEMO KIT MODE OFF/ON (current
setting), press 1 (off) or 2 (on). The display flashes the entered setting.
2. Press #. The display shows DEMO KIT MODE OFF/ON (new
setting).