Installation Manual Instruction Manual

Chapter 3: Programming
46 Concord 4 Installation Manual
Multipartition
arm/disarm
Shortcut: 0004
Default: Off. Partition to
turn on
This feature controls which partitions (1 to 6) can be armed/disarmed
simultaneously when using a touchpad and access code assigned to
those partitions. When enabled, users can arm/disarm selected
partitions using an authorized access code. When disabled, multiple
partitions cannot be armed/disarmed simultaneously. For this feature:
At least two partitions must be selected.
Touchpads must be assigned to at least one of the selected
partitions of this menu.
Access codes must be assigned to all selected partitions of this
menu. If the partition assignment for a specific access code does not
match the partitions selected in this menu, only those partitions
common to both menu settings can be armed/disarmed
simultaneously with that code.
A partition cannot be armed/disarmed if it is being controlled by
another source at that time.
All arming modifiers except Silent affect all partitions being armed.
Only the arming partition can be armed silently.
When arming multiple partitions, any conditions that prevent arming
are identified on touchpad displays with the affected partition number
flashing. The normal protest/auto force arm sequence follows, or
pressing * cancels the arming request.
When disarming multiple partitions, any partitions in alarm have the
affected partition number flashing on touchpad displays. Pressing #
cancels all alarms in the selected partitions. Alarm memory
information is then displayed for all canceled alarms.
To disable mulitipartition arm/disarm, with the display showing
MULTI-PTN ARM/DISARM n n n n n n n, select all of
the partitions by entering the appropriate partition number. The
partition numbers disappear from the display. Press #.