Phones - central station phone 1 to 3 settings
Phone number
Shortcut: 01000,
01010, and 01020
Default: None
Use this setting to program the central station receiver phone number.
Phone numbers can be 1 to 24 digits long, including pauses or *and #
characters.
The phone menus are not accessible if a dealer code is programmed
and the installer code is used to enter installer programming mode. To
access these menus when a dealer code is programmed, you must
enter installer programming mode using the dealer code. Call-waiting
services should be disabled to prevent interrupting panel communication
to the central monitoring station. To program a dialing prefix that
disables call waiting, see the call wait cancel setting under the menu
Phone options - global settingson page 54.
To delete a central station phone number, with the display showing
PHONE NUMBER (current number), press D. The display shows
PHONE NUMBER _.
High level reports
Shortcut: 01001,
01011, and 01021
Default: On (1),
Off (2 and 3)
When this setting is on, the following conditions report to the central
station:
Fire, police, auxiliary, and duress alarms
No activity
Receiver failure (or jam)
Tamper conditions, including zone tampers and system tamper (40
incorrect key presses or touchpad supervisory)
Entering or exiting sensor test mode
Phone test
Low level reports
Shortcut: 01002,
01012, and 01022
Default: On (1),
Off (2 and 3)
When this setting is on, the following nonalarm conditions report to the
central station:
Force armed
Hardwired zone trouble (open or short)
Supervisory (wireless devices)
Low battery (wireless devices)
Phone test
Other nonalarm related conditions
Exception reports
Shortcut: 01003,
01013, and 01023
Default: Off
When this setting is on, the panel reports to the central station if the
system is not armed or disarmed at the specified schedule times.
Open/close reports
Shortcut: 01004,
01014, and 01024
Default: Off
This setting determines whether opening and closing reports are sent to
the central station. When turned on, the panel sends a closing report
when the system is armed and an opening report when the system is
disarmed.
To use this feature, the opening reports and closing reports settings
under theReporting menu on page 61 must be turned on for that
partition.