Installation Manual Instruction Manual

Chapter 3: Programming
54 Concord 4 Installation Manual
Phones - downloader phone settings
Phone number
Shortcut: 01090
Default: None
Use this setting to enter the phone number of an offsite computer that
can be used to program the panel through the phone line. Phone
numbers can be 1 to 24 digits long, including pauses or * and #
characters.
Call-waiting services should be disabled to prevent interrupting panel
communication to the downloader. To program a dialing prefix that
disables call waiting, see the call wait cancel setting under the “Phone
options - global settingsbelow.
To delete a downloader phone number, with the display showing
PHONE NUMBER (current number), press D to erase the number.
The display shows PHONE NUMBER_.
Phone options menu
A phone interface/voice module must be installed for the system to use these
settings (except line fail delay).
Phone options - global settings
Phone test
Shortcut: 02000
Default: On
This setting determines if you can test the communication from the
panel to the central station or a pager by entering 8, code, 2 (#, 8,
code, 2 from a touch tone phone).
Automatic phone test
Shortcut: 02001
Default: Off
This setting determines if the panel sends a phone test automatically
to the central station or a pager on a predetermined schedule. (See
Phone test freq. and Next phone test under Timers -global settings
on page 57).
Automatic test reset
Shortcut: 02002
Default: On
This setting determines whether the automatic phone test interval is
reset after any successful report to the central monitoring station. (See
Phone test freq. and Next phone test under Timers -global settings
on page 57). When this feature is on, the panel considers any
successful report to the central monitoring station to be a successful
phone test. Thus, any panel report resets the next phone test setting
to the phone test frequency value. The panel only conducts an
automatic phone test if no other reports have been made during the
phone test frequency time. Phone test frequency must be set to 2 or
higher for automatic test reset to work.
When this feature is off, an automatic phone test is always conducted
according to the schedule of the phone test frequency setting, even if
the panel makes other reports to the central monitoring station during