Reporting menu
Reporting - global settings
24-hour tamper
Shortcut: 06000
Default: Off
When this setting is turned on, the panel sounds sirens and reports a
tamper alarm (even when the system is disarmed), when nonfire
wireless sensor tamper switches are activated.
When this setting is turned off, the panel sounds sirens and reports a
tamper alarm only when nonfire wireless sensor tamper switches are
activated and those sensors are active for the current arming level.
For nonfire sensors not active in the current arming level that have
their tamper switch activated, trouble beeps sound and the panel
sends a sensor tamper report to the central station if the system
tamper feature is on for that partition.
Tamper conditions for fire sensors (group 26) always cause trouble
beeps to sound and report the tamper condition to the central station,
regardless of this feature setting.
Antenna tamper
Shortcut: 06001
Default: Off
This setting determines whether the panel monitors for antenna
tamper of onboard and all connected bus transceivers and receivers.
When turned on, the panel sounds trouble beeps in all partitions and
reports an antenna tamper condition. Touchpads in all partitions show
a receiver tamper trouble condition. When turned off, the panel
ignores antenna tampers.
Buffer control
Shortcut: 06002
Default: Off
When this setting is on, only arming level changes and time changes
(system time and daylight saving time) are logged in the buffer
(memory) of the panel. When this setting is off, all system events are
logged in the buffer.
Back in service
Shortcut: 06003
Default: On
When this setting is on, the panel reports to the central station when
AC and backup battery power are restored (after an extended power
outage).
Bypass reports
Shortcut: 06004
Default: Off
When this setting is on, the panel reports to the central station
whenever sensors or zones are bypassed.
Low CPU battery
Shortcut: 06005
Default: On
When this setting is on, the panel reports a low panel battery to the
central station when the system battery test fails. If this setting and the
Aux power fail feature are both on, the panel also monitors for and
reports a low battery for the SuperBus 2000 2-amp power supply.
Battery restoral
Shortcut: 06006
Default: Off
If this setting is on, the panel reports to the central monitoring station
when a wireless sensor or touchpad reports a battery replacement to
the panel.
Buffer full report
When this setting is on, the panel sends an event buffer full report to
the central monitoring station when the event buffer is nearing full.