Installation Manual Instruction Manual

Chapter 3: Programming
64 Concord 4 Installation Manual
Reporting - partition 1 to 6 settings
Opening reports
Shortcut: 06100 to
06600
Default: Off
When this setting is on, the panel sends an opening report to the
central station after disarming the system.
To use this feature, the open/close reports settings under the Phones
menu on page 50 must be turned on for the specific CS phone or
pager number.
Closing reports
Shortcut: 06101 to
06601
Default: Off
When this setting is on, the panel sends a closing report to the central
station after arming the system.
To use this feature, the open/close reports settings under the Phones
menu on page 50 must be turned on for the specific CS phone or
pager number.
No activity option
Shortcut: 06102 to
06601
Default: Off
When this setting is on, the panel sends a no activity report to the
central station when the activity timeout expires.
Duress option
Shortcut: 06103 to
06603
Default: Off
When this setting is on, the system can be controlled using a
programmed duress code (see “Security - partition 1 to 6 setting on
page 49) and will send a duress alarm to the monitoring station.
Do not use a duress code unless it is necessary. Using duress codes
often results in false alarms due to code entry errors. If a duress code
is necessary, use it with the audio verification module to reduce false
alarms and accidental dispatches. The audio verification module is
listen only.
Force armed
Shortcut: 06104 to
06604
Default: Off
When this setting is on, the panel reports to the central monitoring
station when you force arm” the system.
Forced arming occurs if you press Bypass when arming the system
with open sensors/zones protesting. Auto-forced arming occurs when
you do not press Bypass when arming the system with open
sensors/zones protesting, and then leave through an entry/exit door
and the arming protest period expires. This causes the system to
automatically bypass the open (protesting) sensors. Auto-forced
arming always reports to the central monitoring station.