Chapter 3: Programming
66 Concord 4 Installation Manual
Siren options menu
Siren options - global settings
Immediate beeps
Shortcut: 0700
Default: Off
This setting determines whether the panel activates trouble beeps as
soon as a wireless device supervisory condition is detected (on), or if
the panel waits 10 hours after the supervisory condition is detected to
activate trouble beeps (off). (See Timers -global settingson page 57).
Disable trouble beeps
Shortcut: 0701
Default: Off
When you turn on this setting, the panel does not initiate beeps to alert
users of nonfire wireless device supervisory trouble and does not
protest on arming if the condition exists.
If Immediate beeps is on, trouble beeps sound for supervisory trouble
conditions regardless of this menu setting.
UL 98 options
Shortcut: 0702
Default: Off
This setting determines whether the panel complies with UL 98
requirements (4-hour trouble beep restart, 4-hour backup battery test, 4-
hour smoke (group 26) zone supervisory).
Global fire
Shortcut: 0703
Default: Off
This setting determines whether sirens in all partitions sound (on) if any
partition activates a fire alarm.
Silent panic
Shortcut: 0704
Default: Off
This setting determines whether touchpad police panic alarms are
audible (off) or silent (on).
Siren options - partition 1 setting
Siren verify
Shortcut: 0710
Default: Off
This setting determines whether the panel supervises the panel speaker
terminals (7 and 8). When this feature is on, the panel indicates a
trouble condition if no speaker is connected to panel speaker terminals.