Installation Manual Instruction Manual

Chapter 3: Programming
Concord 4 Installation Manual 67
Sensors menu
Learn sensors
Shortcut: 080
Default: None
The panel comes with factory programmed onboard hardwired zones.
Install 2 kohm, end-of-line (EOL) resistors on all factory programmed
hardwired zones. If you don’t want to install EOL resistors, delete any
unused zones from memory. Sensors must be placed in a partition or
sensor group. To change the sensor group or partition assignment after
adding a sensor or zone, use the Edit sensors menu.
To add (learn) sensors into panel memory:
1. With the display showing SENSORS, press # and the display shows
LEARN SENSORS.
2. Press # and the display shows SENSOR PTN 1.
3. Press # to select partition 1 or press 2, 3, 4, 5, or 6, # to select the
desired partition. The display should show SENSOR GROUP 0.
4. Enter the sensor group and press #. (See Table 24 on page 130 for a
description of all sensor group characteristics.) The display shows
TRIP SENSOR nn, where nn is the displayed (next available)
sensor number.
5. To change the displayed sensor number, enter the desired sensor
number and press #. The desired sensor number is displayed.
6. With the desired sensor number displayed, use the guidelines in
Table 12 on page 70 to force the sensor or zone you are adding
(learning) into the panel memory to send a signal to the panel.
7. To add another sensor to the same sensor group and partition, repeat
the process.
8. To add sensors to another sensor group or partition, press * twice
and repeat the process.
The factory default zone inputs and group number are:
Zone input 1 Group 10 (entry/exit)
Zone input 2 Group 17 (instant interior follower)
Zone input 3 to Zone input 8 Group 13 (instant perimeter)
If the panel memory is cleared, all onboard zone factory programming
will be erased.