Installation Manual Instruction Manual

Chapter 3: Programming
Concord 4 Installation Manual 71
Audio verification menu
The Audio verification menu lets you set up the audio verification module (AVM)
operation in partition 1. If you want audio verification for partitions 2 to 6, you
must install a standalone audio verification module and a four-relay output
module (HOM) (60-770) output for that partition.
Audio verification - partition 1 settings
Audio verify
Shortcut: 09000
Default: Off
This setting determines whether the system can be accessed by phone
for alarm verification.
Audio mode audio
verification
Shortcut: 09001
Default: 1
This setting determines how the audio verification module operates.
Choose one of the following:
Instant (1): Allows the central station operator instant access for an
audio session by entering the AVM code or by pressing * (if an AVM
access code is not programmed) upon completion of panel alarm report
(see Access timeout below). The panel does not report any alarms
during the AVM session except for fire alarms, even if the operator
extends the session by pressing any valid key.
Callback (2): Allows the central station operator to place a call to the
premises within 5 minutes of the alarm report (panel picks up after one
ring). The operator must press * or enter the AVM access code within 20
seconds after ring. The panel does not report any alarms during the
AVM session except for fire alarms, even if the operator extends the
session by pressing any valid key.
Callback silent (3): Same as Callback, except premises phones do not
ring.
Fire shutdown
Shortcut: 09002
Default: Off
This setting determines whether system sirens turn off during a fire
alarm audio session.
Silent talkback
Shortcut: 09003
Default: Off
This setting determines whether the central station operator can speak
to persons on the premises (on) or only listen (off) during a silent or
duress alarm audio session.
Access timeout
Shortcut: 09004
Default: 90 seconds
If the audio mode is set to Instant, then this setting determines how
much time (30 to 300 seconds, in 2-second increments) the central
station operator has to enter the AVM access code after the panel is
accessed for an audio session.
Beep delay
Shortcut: 09005
Default: 2 seconds
This setting determines how long AVM access beeps are delayed (0 to
300 seconds, in 2-second intervals) at the beginning of a two-way audio
session.