Device ID
Default: None
This menu lets you change the bus device ID number when replacing a
defective bus device.
To change a device ID:
1. With the display showing the desired bus device, press #, #. The
display shows DEVICE ID (current ID).
2. Enter the ID of the new bus device. The display flashes the entered
selection. Press # and the display shows the new setting.
3. Exit programming mode.
4. Remove AC and battery power from the panel.
5. Replace the defective bus device with a new one.
6. Apply AC and battery power to the panel.
Partition assign
This menu lets you assign bus devices to work in the desired partition.
Note: SuperBus 2000 8Z input modules, SuperBus 2000 4-relay output
modules, and SuperBus 2000 RF receivers are not assigned to
partitions.
To assign bus devices to partitions:
1. With the display showing the desired bus device, press #.
2. Press A or B until the display shows DEVICE PTN and then press
#. The display shows PARTITION ASSIGN n.
3. Press 1 to 6 to select the desired partition. The display flashes the
entered selection. Press # and the display shows the new setting.